• 제목/요약/키워드: parallel line

검색결과 952건 처리시간 0.03초

평행라인 피봇식 추력베어링의 동특성 해석 (Dynamic Characteristics of Parallel tine Pivoted Pad Thrust Bearing)

  • 이경우;김종수;제양규
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제29회 춘계학술대회
    • /
    • pp.111-118
    • /
    • 1999
  • In this paper, linearized dynamic characteristics of parallel line pivoted pad thrust bearing(hereinafter refer to PLP thrust bearing) was analyzed by perturbation method with inlet pressure. Inlet pressure and excitation frequency irfluence dynamic characteristics of PLP thrust bearing at all operating condition, such as angular pivot position, mass of pad. Therefore, the characteristics is have to analyzed with inlet pressure, excitation frequency, mass of pad and thickness of pad. Otherwise, the analysis is able to estimate the characteristics over or under.

  • PDF

SOP Image SRAM Buffer용 다양한 데이터 패턴 병렬 테스트 회로 (Parallel Testing Circuits with Versatile Data Patterns for SOP Image SRAM Buffer)

  • 정규호;유재희
    • 대한전자공학회논문지SD
    • /
    • 제46권9호
    • /
    • pp.14-24
    • /
    • 2009
  • System on panel 프레임 버퍼를 위한 메모리 셀 어레이와 주변회로가 설계되었다. 또한, system on panel 공정의 낮은 yield를 극복하기 위해, 블럭 단위의 parallel test 방안이 제안되었다. 기존의 메모리 테스트 보다 빠르게 fault detection이 가능하며, 다양한 embedded memory나 일반 SRAM 테스트 분야에도 적용 가능하다. 또한 기존의 다양한 test vector pattern이 그대로 적용될 수 있어 fault coverage가 높고, 최근의 추세인 hierarchical bit line과 divided word line 구조에도 적용될 수 있다.

FLCLM과 평행 결합 선로를 이용한 협대역 소형 개방형 스터브 대역통과 필터 (Compact Narrow Open-stub Band-pass Filter using FLCLM and Parallel Coupled line)

  • 홍태의
    • 대한전자공학회논문지TC
    • /
    • 제48권3호
    • /
    • pp.68-73
    • /
    • 2011
  • 본 논문은 평행 결합 선로와 FLCLM(Frquency Locked Controlled Length Method)을 이용하여 저주파의 기생 신호 와 2차 고조파가 억압된 소형 협대역 개방형 스터브 대역통과 필터에 대하여 새롭게 제안 하였다. 평행 결합 선로의 특징은 저파주대역의 기생 신호와 2차 고조파를 억압 할 수가 있다. 최종 설계한 필터의 실험 결과에서 사용되는 대역의 중심 주파수는 5.8 GHz 이고 대역폭 10 % 이며 삽입 및 반사 손실은 각각 1.2 dB 및 14.8 dB 이다. 추가적으로 저주파 및 고조파 억제는 각각 28.9 dB 및 28.8 dB 이다.

결함 기저면 구조 인버터를 이용한 평행 결합 선로 대역 통과 필터 (A Parallel Coupled Line Band Pass Filter Using Defected Ground Structure Inverter)

  • 김인선
    • 한국전자파학회논문지
    • /
    • 제19권1호
    • /
    • pp.54-60
    • /
    • 2008
  • 본 논문에서는 결함 기저면 구조(DGS) 인버터를 이용하여 평행 결합 선로 대역 통과 필터를 설계하는 새로운 방법을 제안하였다. 이 방법은 전송선 인버터 구조의 필터 설계 시 높은 임피던스로 발생하는 선로 폭 제한 문제를 쉽게 해결할 수 있다. 제안한 방법과 기존 방법에 근거하여 13.3 %의 대역폭율을 갖는 대역 통과 필터가 설계 및 제작되었다. 두 필터의 측정 곁과는 비교적 잘 일치한다. 반면에 기존 필터에 비해 제안 필터 길이는 약 15 mm 축소되었고, 인버터 선로 폭은 2배 이상 확장되었다.

적층 Inter-Digital 공진기를 이용한 2.4 GHz 대역 LTCC 대역통과 여파기의 등가회로 설계 (Equivalent Circuit Design of 2.4 GHz Band LTCC Bandpass Filters Using Multilayer Inter-Digital Resonators)

  • 성규제
    • 한국전자파학회논문지
    • /
    • 제16권1호
    • /
    • pp.78-83
    • /
    • 2005
  • 본 논문에서는 적층 Inter-digital 공진기를 이용한 LTCC 대역통과 여파기의 등가회로를 제안하고, 2.4 GHz 대역의 여파기 설계에 적용하였다. 본 논문의 LTCC 적층 칩 대역통과 여파기는 평면상에서는 Comb-line 구조이고 단면상에서는 Inter-digital 구조로 구성된다. Comb-line 구조와 Inter-digital 구조의 평행 결합선로의 등가회로를 본 논문의 여파기에 적용하여 여파기 전체의 등가회로를 구성하였다. 이 등가회로는 공진기 사이의 결합 구조가 다중의 결합 구조를 갖는다. 이를 하나의 결합 구조로 통합하여 인버터를 이용한 대역통과 여파기의 설계방법을 적용하였다. 2.4 GHz 대역에서 3단의 대역통과 여파기를 설계, 제작하였다.

병행 배전선로에서의 통신선 유도전압 계산 (Calculation of an Induced Voltage on Telecommunication Lines in Parallel Distribution Lines)

  • 김현수;이상봉;여상민;김철환;류승헌;김성암;원봉주
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1688-1695
    • /
    • 2008
  • Recently, it is common in a distribution system of Korea Electric Power Corporation (KEPCO) to find instances where distribution lines are parallel. A traditional method of an induced voltage calculation is not suitable for parallel distribution lines. For more actual analysis of induced voltage on telecommunication lines in parallel distribution lines, a new calculation method is needed. This paper presents a new calculation method of an induced voltage on telecommunication line using equivalent ${\pi}$ circuits matrix in parallel distribution lines. The advantages of the calculation method are using actual neutral current value and not using screening factor for considering the overhead ground wire and the neutral wire. To verify the effectiveness and the accuracy of the method, various case studies are performed with EMTP(Electro-Magnetic Transients Program).

온라인 무정전전원장치의 병렬운전 제어기술 (Parallel Operation Control Technique of On-line UPS System)

  • 조준석;강병희;고재석;최규하;김진홍;정석언
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.501-505
    • /
    • 2001
  • The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between inverters on synchronous d-q reference frame.

  • PDF

π-형 전송선 급전 구조를 갖는 대역 통과 필터 (A Band Pass Filter with Feeding Structure Using π-Type Transmission Line)

  • 배주석;임종식;김귀수;안달
    • 한국전자파학회논문지
    • /
    • 제19권2호
    • /
    • pp.114-120
    • /
    • 2008
  • 본 논문에서는 일반적인 반 파장 평행 결합 선로 대역 통과 필터의 입 출력 결합 선로를 K-인버터로 변환하고, K-인버터를 $\pi$-형 전송선 등가로 대체함으로써 $\pi$-형 전송선 급전 구조를 갖는 구조의 대역 통과 필터를 제안하였다. 이 방법은 반 파장 결합 선로 대역 통과 필터의 입 출력 결합 선로 구현 문제에 대한 해결 방안을 제시한다. 또한, 기존의 탭 선로(tapped line) 구조의 설계 방법에 비해 설계 식이 매우 간단하고 정확하여, 특성의 적정화를 위한 노력과 시간을 상당히 줄일 수 있다. 제안된 이론을 바탕으로 $\pi$-형 전송선 급전 구조를 갖는 구조의 대역 통과 필터를 설계 및 제작하였고, 그 결과로부터 제안 방법의 타당성을 입증하였다.

Design of A 1'${\times}$1', 512${\times}$512 Poly-Si TFT-LCD with Integrated 8-bit Parallel-Serial Digital Data Drivers

  • Shin, Won-Chul;Lee, Seung-Woo;Chung, Hoon-Ju;Han, Chul-Hi
    • Journal of Information Display
    • /
    • 제2권2호
    • /
    • pp.1-6
    • /
    • 2001
  • A $1"{\times}l"$, $512{\times}512$ poly-Si TFT-LCD with a new integrated 8-bit parallel-serial digital data driver was proposed and designed. For high resolution, the proposed parallel-serial digital driver used serial video data rather than parallel ones. Thus, digital circuits for driving one column line could be integrated within very small width. The parallel-serial digital data driver comprised of shift registers, latches, and serial digital-to-analog converters (DAC's). We designed a $1"{\times}l"$, $512{\times}512$ poly-Si TFT-LCD with integrated 8-bit parallel-serial digital data drivers by a circuit simulator which has physical-based analytical model of poly-Si TFT's. The fabricated shift register well operated at 2 MHz and $V_{DD}$=10V and the fabricated poly-Si TFT serial DAC's, which converts serial digital data to an analog signal, could convert one bit within $2.8{\mu}s$. The driver circuits for one data line occupied $8100{\times}50{\mu}m^2$ with $4{\mu}m$ design rule.

  • PDF

직렬 능동 보상기를 이용한 Line-Interactive UPS의 새로운 제어 기법 (A New Control Scheme of the Line-Interactive UPS Using the Series Active Compensator)

  • 장훈;이우철;현동석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권8호
    • /
    • pp.405-412
    • /
    • 2003
  • This paper presents a three-phase Line-Interactive uninterruptible power supply (UPS) system with series-parallel active power-line conditioning capabilities, using synchronous reference frame (SRF) based controller, which allows an effective power factor correction, source harmonic voltage compensation, load harmonic current suppression, and output voltage regulation. The three-phase UPS system consists of two active power compensator topologies. One is a series active compensator, which works as a voltage source in phase with the source voltage to have the sinusoidal source current and high power factor under the deviation and distortion of the source voltage. The other is a parallel active compensator which works as a conventional sinusoidal voltage source in phase with the source voltage, providing to the load a regulated and sinusoidal voltage with low THD (total harmonic distortion). The control algorithm using SRF method and the active power flow through the Line-interactive UPS systems are described and studied. The simulation and experimental results are depicted in this paper to show the effect of the proposed algorithm.