• 제목/요약/키워드: panel heating

검색결과 185건 처리시간 0.028초

바닥난방 시스템용 비례식 자동온도조절밸브의 성능해석에 관한 연구 (A Study on the Performance Analysis of Proportional Automatic Thermostatic Valves in Floor Radiant Heating System)

  • 송재엽;안병천;김용기;이태원
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.52-57
    • /
    • 2007
  • The control characteristics for radiant panel heating system with automatic thermostatic valves were researched by computer simulation and experiment. The unsteady energy analysis using equivalent R-C circuit method and radiation heat transfer analysis of enclosure analysis method with simple structured rooms was performed. The results of flow rate changes of the simulation study are good fit with the ones of experimental one.

  • PDF

외기전담 시스템 기반 초고층 공동주택 중앙 환기시스템의 에너지 절감효과 분석 (Energy Saving Potentials of Dedicated Outdoor Air System in a High-rise Apartment Building)

  • 김민휘;김진효;권오현;정재원
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.291-296
    • /
    • 2009
  • This paper investigates the energy saving potentials of a dedicated outdoor air system (DOAS) applied to a highrise apartment building. As for a typical $132-m^2$ apartment unit, two different HVAC systems; centralized DOAS-Ceiling Radiant Cooling Panel and decentralized Energy Recovery Ventilator-Packaged Air Conditioner were installed. Transient behavior and control characteristics of each system were modeled numerically using a commercial equation solver program, and annual cooling coil load and heating load reduction potentials were compared. The research shows that DOAS-Ceiling Radiant Cooling Panel system can reduce the cooling coil load over 21% annually compared with the current Energy Recovery Ventilator-Packaged Air Conditioner pair. In addition, over 40% of annual ventilation heating load can be reduced by use of DOAS.

  • PDF

하나로 기체시료채취계통에서 생성된 응축수 억제를 위한 CFD 해석 (CFD Analysis to Suppress Condensate Water Generated in Gas Sampling System of HANARO)

  • 조성환;이종현;김대영
    • 방사성폐기물학회지
    • /
    • 제18권2_spc호
    • /
    • pp.327-336
    • /
    • 2020
  • HANARO (High-flux Advanced Neutron Application Reactor)는 우라늄의 핵분열 연쇄반응에서 생성된 중성자를 이용하여 다양한 연구개발을 수행하는 열출력 30 MW 규모의 연구용 원자로이다. 탈기탱크는 HANARO의 부속시설에 설치되어 있다. 탈기탱크는 내부환경요인으로 인해 기체오염물질을 발생시킨다. 탈기탱크는 기체오염물질을 허용 가능한 수준 이하로 유지하기위해 필요하며 기체시료채취판넬의 분석기에 의해 모니터링 된다. 응축수가 발생하여 기체시료채취판넬의 분석기 내부로 유입된다면, 분석기의 측정 챔버 내부에 부식이 발생하여 고장을 야기한다. 응축수의 생성 원인은 탈기탱크에 존재하는 기체가 분석기로 유입되는 과정에서 탈기탱크와 분석기사이 온도 차이다. 응축수 생성을 억제하고 계통 내부에 생성된 응축수를 효율적으로 제거하기 위해 탈기탱크와 기체시료채취판넬 사이에 히팅시스템이 설치되었다. 이 연구에서 우리는 히팅시스템의 효율성을 알고자 한다. 또한 Wall Condensation Model을 이용하여 유체 입구온도, 외부온도 및 히팅 케이블 설정온도 변화에 따른 파이프 온도와 평균응축량의 변화를 모델링하였다.

건물통합을 위한 태양에너지 cogeneration panel 특성 분석 연구 (The Performance Assessment Study of Solar Energy Cogeneration panel for Building Integrated System)

  • 김용환;강은철;현명택;이의준
    • 한국태양에너지학회 논문집
    • /
    • 제26권2호
    • /
    • pp.35-42
    • /
    • 2006
  • Solar Thermal-Electric Integrated system can be used to generate heat and electricity simultaneously and can improve indoor all qualify. So, it can save heating and electricity cost as it operates at relatively lower temperatures. In this study, one pv module was fixed on a normal wall and a pv module was mounted on a solarwall. And a ventilation fan in the solar energy cogeneration panel was operated from 12:00 to 17:00 hours. Experimental results are recorded and anaysized. The comparison of results show that the temperature of PV on solar energy cogeneration panel was decreased by $7{\sim}9^{\circ}C$ and the electrical output was improved by $2{\sim}3W$ compared with a PV system without solarwall.

Inorganic Polymer Concrete를 이용한 경량패널의 내화특성에 관한 실험적 연구 (Study on the Fire Resistance of Light Weight Inorganic Polymer Concrete Panel Wall)

  • 황지순;김우재;김대회;박동철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.205-206
    • /
    • 2011
  • 이노가닉 폴리머 콘크리트는 비소성 알카리 활성화 콘크리트의 일종으로 여러 가지 우수한 성능을 가지고 있으며, 그 중에서도 고온에서의 열적특성이 우수한 것으로 알려져 있다. 이에 따라, 이노가닉 폴리머 콘크리트를 이용한 경량패널을 제조하여, 소형가열로 내화시험을 측정한 결과 3시간 가열후 이면상승온도가 평균 82℃ 이하로 확인되어 공동주택의 내화벽체로 활용이 가능할 것으로 판단된다.

  • PDF

샌드위치패널심재로 활용한 St/BA 개질 다공성 경량 콘크리트의 특성 (Properties of St/BA Modified Cellular Lightweight Concrete as Sandwich Panel Core)

  • 강내민;노정식;도정윤;문경주;소양섭
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.31-34
    • /
    • 2003
  • Sandwich panel is composed of the facing sheets which support the external load, the cellular core with the low thermal conductivity and the adhesive agent to bond them. The cellular core was produced by binding lightweight cellular aggregates with cement and two types of acrylic base St/BA emulsion were added with a view to improving the workability ion due to high absorption of light weight aggregate and to develope more strength, respectively. This investigation is to comprehend the effect of the addition of two types of St/BA on thermal conductivity, calorific value and exhaustion content of noxious gas in addition re compressive and flexural strength. Flexural strength of the specimen made with St/BA-2 ranged 20kgf/cm2 to 25kgf/cm2 and was about 50% to 100% as high as that of the non-fiber specimen. Thermal conductivity was recorded from 2.0 to 3.0 kcal/mh$^{\circ}C$ and calorific value of St/BA modified specimen was much lower than that of commercial sandwich panel core of EPS and urethane. Careful caution has to be taken because generation of noxious gas such as CO, NO and SO2 tend to increase with addition of polymer cement ratio.

  • PDF