• Title/Summary/Keyword: p-s curve

Search Result 750, Processing Time 0.039 seconds

Diffusion tensor imaging of the C1-C3 dorsal root ganglia and greater occipital nerve for cervicogenic headache

  • Wang, Lang;Shen, Jiang;Das, Sushant;Yang, Hanfeng
    • The Korean Journal of Pain
    • /
    • v.33 no.3
    • /
    • pp.275-283
    • /
    • 2020
  • Background: Previous studies showed neurography and tractography of the greater occipital nerve (GON). The purpose of this study was determining diffusion tensor imaging (DTI) parameters of bilateral GONs and dorsal root ganglia (DRG) in unilateral cervicogenic headache as well as the grading value of DTI for severe headache. The correlation between DTI parameters and clinical characteristics was evaluated. Methods: The fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values in bilateral GONs and cervical DRG (C2 and C3) were measured. Grading values for headache severity was calculated using a receiver operating characteristics curve. The correlation was analyzed with Pearson's coefficient. Results: The FA values of the symptomatic side of GON and cervical DRG (C2 and C3) were significantly lower than that of the asymptomatic side (all the P < 0.001), while the ADC values were significantly higher (P = 0.003, P < 0.001, and P = 0.003, respectively). The FA value of 0.205 in C2 DRG was considered the grading parameter for headache severity with sensitivity of 0.743 and specificity of 0.999 (P < 0.001). A negative correlation and a positive correlation between the FA and ADC value of the GON and headache index (HI; r = -0.420, P = 0.037 and r = 0.531, P = 0.006, respectively) was found. Conclusions: DTI parameters in the symptomatic side of the C2 and C3 DRG and GON were significantly changed. The FA value of the C2 DRG can grade headache severity. DTI parameters of the GON significantly correlated with HI.

An Experimental Investigation of the Variations of the Elastic Wave Velocities with Compaction Energy for Railway Roadbed Materials (다짐 에너지를 고려한 노반 성토 재료의 탄성파 속도 변화의 실험적 분석)

  • Kim, Hak-Sung;Jung, Young-Hoon;Mok, Young-Jin;Lee, Jin-Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.1037-1047
    • /
    • 2013
  • A systematic laboratory compaction testing was performed with the laboratory seismic measurements of the compacted specimens sampled from various compaction fills and was supplemented with in-situ seismic testing to investigate the effects of compaction energy on the elastic wave velocities of the railway roadbed materials. The both variances of the compressive and shear wave velocities with moisture content curve ($V_p$-w and $V_s$-w curves) are similar to the general trend of the density-moisture content curve(${\gamma}_d$-w curve). At the wet side of optimal moisture content (OMC), either $V_p$ or $V_s$ does not significantly increase, which is well reflecting the no gaining in density with the increasing compaction energy exceeding modified-D compaction effort. $V_p$ increases linearly with ${\gamma}_d$ at the dry side of OMC, while it does exponentially at the wet side. The in-situ wave velocities were found to be influenced by the level of confinement and $V_s$ was more sensitive to compaction energy than $V_p$.

The Influence Of The Cathode Surface State On The Spark Voltage In The Low Pressure Gare Gas (저기압희유 gas중에서 불꽃전압에 미치는 음극표면상태의 영향)

  • 백용현
    • 전기의세계
    • /
    • v.23 no.4
    • /
    • pp.46-52
    • /
    • 1974
  • Generally, it has been regarded that there are two kinds of the effect of the electrodes, especially of the cathode in the gas discharge, (a) the effect caused by the difference of the cathode meterial and (b) the effect by the change of the cathode surface state even in the same meterials. Thus the two effects must be investigated independently to study the roles of the cathode in gas discharges. This paper measured sparking voltage in Rare gas (Ar, He) for the change of sparking voltage in repeating sparks and for the effect of (a) and (b) mentioned above, under the condition that the desorption of impurities from the cathod can be nigligible, and it is obtained that the correlative relations of the work function, sparking voltage and secondary coefficient are comparatively simple. In addition, the interesting character of the minimum point of the paschen's curves is found. The results were as follows; 1) The value of (pd)min with minimum pint of sparking voltage, (Vs)min, is 0.7-0.9 Torr. cm in Argon, but is 5.6-7.1 Torr. cm in Helium, and Paschen's curve in Helium shows slow curve than in Argon. 2) The minimum point of the Paschen's curve is satisfied actually Townsend's self sustaining criterion in Argon, but non-satisfaction in Helium, and the Townsend's secondary coefficient .gamma. action have compound property (.gamma.$_{i}$, .gamma.$_{p}$, .gamma.$_{m}$) in Helium. 3) The dependenting character of work function in Helium is less than in Argon. 4) The minimum point of sparking voltage increase under oxidized electrode than clear electrode in Au and Ag, but minimum point decrease in Ni and Cu.

  • PDF

Analysis of the Current-voltage Curves of a Cu(In,Ga)Se2 Thin-film Solar Cell Measured at Different Irradiation Conditions

  • Lee, Kyu-Seok;Chung, Yong-Duck;Park, Nae-Man;Cho, Dae-Hyung;Kim, Kyung-Hyun;Kim, Je-Ha;Kim, Seong-Jun;Kim, Yeong-Ho;Noh, Sam-Kyu
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.321-325
    • /
    • 2010
  • We analyze the current density - voltage (J - V) curve of a Cu(In,Ga)$Se_2$ (CIGS) thin-film solar cell measured at different irradiation power densities. For the solar-cell sample investigated in this study, the fill factor and power conversion efficiency decreased as the irradiation power density (IPD) increased in the range of 2 to 5 sun. Characteristic parameters of solar cell including the series resistance ($r_s$), the shunt resistance ($r_{sh}$), the photocurrent density ($J_L$), the saturation current density ($J_s$) of an ideal diode, and the coefficient ($C_s$) of the diode current due to electron-hole recombination via ionized traps at the p-n interface are determined from a theoretical fit to the experimental data of the J - V curve using a two-diode model. As IPD increased, both $r_s$ and $r_{sh}$ decreased, but $C_s$ increased.

Two Mode Maximum Power Point Tracking for Photovoltaic System

  • Limsakul, Chamnan;Ukakimaphun, Prapas;Prapanavarat, Cherdchai;Chenvidhya, Dhirayut
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.143-148
    • /
    • 2004
  • This paper presents the two modes for maximum power point tracking of the photovoltaic system. The method combines the merits of the two methods consisting of the open circuit method and the three point weight comparison method. The maximum point found by this method is exactly than by the open circuit method. By the simulation results, the actual maximum point can be found that is better than the Perturb and Observe (P&O) method or the three point weight method only one method, especially, in the case of non regular pattern of Power-Voltage (P-V) curve.

  • PDF

MEAN LOAD EFFECT ON FATIGUE OF WELDED JOINTS USING STRUCTURAL STRESS AND FRACTURE MECHANICS APPROACH

  • Kim, Jong-Sung;Kim, Cheol;Jin, Tae-Eun;Dong, P.
    • Nuclear Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.277-284
    • /
    • 2006
  • In order to ensure the structural integrity of nuclear welded structures during design life, the fatigue life has to be evaluated by fatigue analysis procedures presented in technical codes such as ASME B&PV Code Section III. However, existing fatigue analysis procedures do not explicitly consider the presence of welded joints. A new fatigue analysis procedure based on a structural stress/fracture mechanics approach has been recently developed in order to reduce conservatism by erasing uncertainty in the analysis procedure. A recent review of fatigue crack growth data under various mean loading conditions using the structural stress/fracture mechanics approach, does not consider the mean loading effect, revealed some significant discrepancies in fatigue crack growth curves according to the mean loading conditions. In this paper, we propose the use of the stress intensity factor range ${\Delta}K$ characterized with loading ratio R effects in terms of the structural stress. We demonstrate the effectiveness in characterizing fatigue crack growth and S-N behavior using the well-known data. It was identified that the S-N data under high mean loading could be consolidated in a master S-N curve for welded joints.

Stochastic Fatigue Life Assesment based on Bayesian-inference (베이지언 추론에 기반한 확률론적 피로수명 평가)

  • Park, Myong-Jin;Kim, Yooil
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.2
    • /
    • pp.161-167
    • /
    • 2019
  • In general, fatigue analysis is performed by using deterministic model to estimate the optimal parameters. However, the deterministic model is difficult to clearly describe the physical phenomena of fatigue failure that contains many uncertainty factors. With regard to this, efforts have been made in this research to compare with the deterministic model and the stochastic models. Firstly, One deterministic S-N curve was derived from ordinary least squares technique and two P-S-N curves were estimated through Bayesian-linear regression model and Markov-Chain Monte Carlo simulation. Secondly, the distribution of Long-term fatigue damage and fatigue life were predicted by using the parameters obtained from the three methodologies and the long-term stress distribution.

Application of Point Shearwave Elastography to Breast Ultrasonography: Initial Experience Using "S-Shearwave" in Differential Diagnosis (Point Shearwave Elastography의 유방 초음파에서의 적용: "S-Shearwave"를 이용한 감별진단의 초기경험)

  • Myung Hwan Lee;Eun-Kyung Kim;Eun Ju Lee;Ha Yan Kim;Jung Hyun Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.157-165
    • /
    • 2020
  • Purpose To evaluate the optimal measurement location, cut-off value, and diagnostic performance of S-Shearwave in differential diagnosis of breast masses seen on ultrasonography (US). Materials and Methods During the study period, 225 breast masses in 197 women were included. S-Shearwave measurements were made by applying a square region-of-interest automatically generated by the US machine. Shearwave elasticity was measured three times at four different locations of the mass, and the highest shearwave elasticity was used for calculating the optimal cut-off value. Diagnostic performance was evaluated by using the area under the receiving operator characteristic curve (AUC). Results Of the 225 breast masses, 156 (69.3%) were benign and 69 (30.7%) were malignant. Mean S-Shearwave values were significantly higher for malignant masses (108.0 ± 70.0 kPa vs. 43.4 ± 38.3 kPa; p < 0.001). No significant differences were seen among AUC values at different measurement locations. With a cut-off value of 41.9 kPa, S-Shearwave showed 85.7% sensitivity, 63.9% specificity, 70.7% accuracy, and positive and negative predictive values of 51.7% and 90.8%, respectively. The AUCs for US and S-Shearwave did not show significant differences (p = 0.179). Conclusion S-Shearwave shows comparable diagnostic performance to that of grayscale US that can be applied for differential diagnosis of breast masses seen on US.

Aquatic Plants for Wastewater Treatment (수생식물을 이용한 수질정화에 관한 연구)

  • 나규환;권성환;이장훈
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.3
    • /
    • pp.49-55
    • /
    • 1996
  • Water parsley(Oenanthe javanica(Blume) DC) was raised with varying population density(S) in the laboratory aquarium unit to determine the growth equation. The population density was measure after 7 days. The resultant growth curve was well fit to the equation 1/S = A+B (1/S0) with a high correlation coefficient ($R^2$ = 0.999). The maximum specific absorption rate was $9.011 \times 10^{-5}$ kg $NO_x-N/kg$ water parsley$\cdot$day and $1.31 \times 10^{-5}$ kg $PO_4-P/kg$ water parsley$\cdot$day when the average population density was $2.62 kg/m^2$. The relationship between population density and nutrient absorption rate, the absorption rate of $NO_x-N$ was 5.04~5.24 mg/l$\cdot$day when the population density was $7.51~10.0 $mg/m^2\cdot day$ and the absorption rate of $PO_4-P$ was 0.56~0.78 mg/l$\cdot$day when the population density was 5.02~10.0 $kg/m^2\cdot day$. Taking into account the nutrient absorption rate and growth rate, the population density between $7.0 kg/m^2\cdot day$ and $8.0 kg/m^2 \cdot day$ was selected. The removal rate of nutrient was investigated after 7 days culture. Removal rate of $NO_x-N$ was 95.6~99.95% with initial concentration of 35 mg $NO_x-N/l$, and the removal rate of $PO_4-P$ was also high, indicating 80.24~98.9% with initial concentration of 5.95 mg $PO_x-P/l$.

  • PDF

Effect of Ethanol on the Protolytic Properties of the Vitamins B Group

  • Ghasemi, J.;Shiri, F.
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.1
    • /
    • pp.21-30
    • /
    • 2007
  • A multiwavelength spectrophotometric titration method was applied to study protolytic constants of four water-soluble vitamins, folic acid(vitamin B9 or B0), thiamine(vitamin B1), riboflavin(vitamin B2) and pyridoxal (vitamin B6) in binary ethanol-water mixtures at 25oC and an ionic strength of 0.1M NaNO3. The protolytic equilibrium constants, spectral profiles, concentration diagrams and also the number of components has been calculated from the curve fitting of the pH-absorbance data with appropriate mass balance equations by an established factor analysis model. DATAN program was used for determination of acidity constant and SPECFIT program was used for calculation of standard deviations and partial correlation coefficients. A glass electrode calibration procedure based on the four parameter equation pH=α+SpcH+JH+[H+]+ JOH-Kw/[H+] based on the Gran,s plots was used to obtain pH-readings in the concentration scale (pcH). The effect of the solvent on the protolytic constants was discussed.