• Title/Summary/Keyword: p-point

Search Result 5,672, Processing Time 0.033 seconds

A P-wave Detection Algorithm by Template Matching Method (템플레이트 매칭에 의한 심전도 신호의 P파 검출 알고리즘에 관한 연구)

  • Hong, Jae-Woo;Jeong, Hee-Kyo;Shin, Kun-Soo;Lee, Myoung-Ho
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1990 no.05
    • /
    • pp.21-24
    • /
    • 1990
  • This paper presents a new algorithm for P-wave detection in the ECG signal, we get the peak, onset and offset point by using significant point extraction algorithm with 5-point derivative. To these set of extracted significant points, we apply amplitude and duration threshold criterion. we define the set of significant point meeting the criterion as P-wave candidate. Then P-wave candidate is classified through match-process with template. The template with maximum number or P-wave candidate is selected to be the P-wave.

  • PDF

NEW COMPLEXITY ANALYSIS OF IPM FOR $P_*({\kappa})$ LCP BASED ON KERNEL FUNCTIONS

  • Cho, Gyeong-Mi;Kim, Min-Kyung;Lee, Yong-Hoon
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.12 no.4
    • /
    • pp.227-238
    • /
    • 2008
  • In this paper we extend primal-dual interior point algorithm for linear optimization (LO) problems to $P_*({\kappa})$ linear complementarity problems(LCPs) ([1]). We define proximity functions and search directions based on kernel functions, ${\psi}(t)=\frac{t^{p+1}-1}{p+1}-{\log}\;t$, $p{\in}$[0, 1], which is a generalized form of the one in [16]. It is the first to use this class of kernel functions in the complexity analysis of interior point method(IPM) for $P_*({\kappa})$ LCPs. We show that if a strictly feasible starting point is available, then new large-update primal-dual interior point algorithms for $P_*({\kappa})$ LCPs have $O((1+2{\kappa})nlog{\frac{n}{\varepsilon}})$ complexity which is similar to the one in [16]. For small-update methods, we have $O((1+2{\kappa})\sqrt{n}{\log}{\frac{n}{\varepsilon}})$ which is the best known complexity so far.

  • PDF

pH Measurement Using Isosbestic Point of Indicator (지시약의 등흡광점을 이용한 용액의 pH 측정)

  • Won-Hyung Choi;Ho-Jang Hur
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.203-207
    • /
    • 1989
  • The methyl red stock solution was added to sample solution and the absorbance values of this solution were measured at the maximum absorption wavelengths of the acidic form, the basic form, and the isosbestic point of the indicator. From the measurements of absorbance, the pH of this solution was calculated. The range of absorbance at the isosbestic point was maintained within 0.1 ${\sim}$ 0.3. The error of pH measurement was within ${\pm}0.08$ pH unit in the pH range of sample solution of $pK_I{\pm}1$.

  • PDF

A WEIERSTRASS POINT OF 𝚪1(4p)

  • Choi, SoYoung
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.21 no.4
    • /
    • pp.467-470
    • /
    • 2008
  • Abstract. We show that the cusp 1=2 is a Weierstrass point of ${\Gamma}_1(4p)$ if p is a prime greater than 7.

  • PDF

CONVERGENCE OF PREFILTER BASE ON THE FUZZY SET

  • Kim, Young-Key;Byun, Hee-Young
    • Korean Journal of Mathematics
    • /
    • v.10 no.1
    • /
    • pp.5-10
    • /
    • 2002
  • In this paper, we investigate the prefilter base on a fuzzy set and fuzzy net ${\varphi}$ on the fuzzy topological space (X,${\delta}$). And we show that the prefilter base $\mathcal{B}({\varphi})$ determines by the fuzzy net ${\varphi}$ converge to a fuzzy point $p$ iff the fuzzy net ${\varphi}$ converge to a fuzzy point $p$. Also we prove that if the prefilter base $\mathcal{B}$ converge to a fuzzy point $p$, then the $\mathcal{B}$ has the cluster point $p$.

  • PDF

A FIXED POINT APPROACH TO THE STABILITY OF THE FUNCTIONAL EQUATION RELATED TO DISTANCE MEASURES

  • Shiny, Hwan-Yong;Kim, Gwang Hui
    • Korean Journal of Mathematics
    • /
    • v.24 no.2
    • /
    • pp.297-305
    • /
    • 2016
  • In this paper, by using fixed point theorem, we obtain the stability of the following functional equations $$f(pr,qs)+g(ps,qr)={\theta}(p,q,r,s)f(p,q)h(r,s)\\f(pr,qs)+g(ps,qr)={\theta}(p,q,r,s)g(p,q)h(r,s)$$, where G is a commutative semigroup, ${\theta}:G^4{\rightarrow}{\mathbb{R}}_k$ a function and f, g, h are functionals on $G^2$.

MULTI-POINT BOUNDARY VALUE PROBLEMS FOR ONE-DIMENSIONAL p-LAPLACIAN AT RESONANCE

  • Wang Youyu;Zhang Guosheng;Ge Weigao
    • Journal of applied mathematics & informatics
    • /
    • v.22 no.1_2
    • /
    • pp.361-372
    • /
    • 2006
  • In this paper, we consider the multi-point boundary value problems for one-dimensional p-Laplacian at resonance: $({\phi}_p(x'(t)))'=f(t,x(t),x'(t))$, subject to the boundary value conditions: ${\phi}_p(x'(0))={\sum}^{n-2}_{i=1}{\alpha}_i{\phi}_p(x'({\epsilon}i)),\;{\phi}_p(x'(1))={\sum}^{m-2}_{i=1}{\beta}_j{\phi}_p(x'({\eta}_j))$ where ${\phi}_p(s)=/s/^{p-2}s,p>1,\;{\alpha}_i(1,{\le}i{\le}n-2){\in}R,{\beta}_j(1{\le}j{\le}m-2){\in}R,0<{\epsilon}_1<{\epsilon}_2<...<{\epsilon}_{n-2}1,\;0<{\eta}1<{\eta}2<...<{\eta}_{m-2}<1$, By applying the extension of Mawhin's continuation theorem, we prove the existence of at least one solution. Our result is new.

A New Algorithm for P_wave Detection in the ECG signal (심전도 신호 P파 검출 알고리즘에 관한 연구)

  • Joang, Hee-Kyo;Kim, Kwang-Keun;Hwang, Sun-Chul;Lee, Myoung-Ho
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1989 no.05
    • /
    • pp.15-18
    • /
    • 1989
  • This paper presents a new algorithm for P-wave detection in the ECG signal. We detect the peak and valley point using significant point extraction algorithm with 9-point derivative. Because P-wave duration is changed according to heart-rates, we search for the R-peak and calculate the R-R interval time prior to the determination of P-wave duration threshold values in order to actively adapt to the change of P duration. We determine the parameters for P-wave detection and then P-peak, P-onset and P-offset are detected by these parameters. The results obtained from the proposed algorithm have detected successively P-wave almost more than 90%.

  • PDF

Comparison of the Interest in Anti-Aging, Need for Anti-Aging Services and the Performance of Health Promotion Behavior by Sex in their 20s (20대 성인에서 성별에 따른 항노화에 대한 관심도 및 건강증진행위 수행도 및 항노화서비스의 필요성 비교)

  • Her, Eun-Sil
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.1
    • /
    • pp.9-17
    • /
    • 2021
  • This aim of this study examined the relationship among the interest in anti-aging, health promotion behaviors and the need for anti-aging services by their 20s. Survey was conducted among adults from their 20s in the Changwon City. 228 responses were used for analysis. The overall average score of the interest and effort of anti-aging were 2.97 point and 2.62 point (out of 5), respectively. And those were both higher in female than men (p<0.01~p<0.001). The overall average score of need for anti-aging service was 3.50 point(total score is 5). In The demand for each area of anti-aging service were ≥3.5 point in all 5 areas, and stress management (4.00 point) was the highest, while the beauty management (3.60 point) was the lowest. There were significant differences in all five areas by sex (p<0.01~p<0.001). The overall score of the performance of health promotion behaviors was 2.44 point(total score is 4), and the interpersonal relationship score (2.85 point) was the highest, while the health responsibility score (2.08 point) was the lowest. The interest in anti-aging and performance of health promotion behaviors showed positive relationship to anti-aging services, and their explanation powers were 34.6% (p<0.001). The results of this study suggest be used as data to establish strategies revitalizing various anti-aging service in the twenties.