• Title/Summary/Keyword: optical resolution

Search Result 1,472, Processing Time 0.059 seconds

The Development of Ultra-precision Aspheric Program for Optical (광학소자용 초정밀 비구면 가공프로그램 개발)

  • 김우순;김동현;난바의치
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.53-57
    • /
    • 2004
  • In this paper, we will present the Aspheric Surface Program for optical element. X-ray optical element designed to give a high resolution and reflectively in order to observe the living cell in the range of the water window. According to optical design, we developed the Aspheric Surface Program using the visual basic. Using the Aspheric Surface Program, we directly machined the electroless nickel bulk.

  • PDF

Super-resolution in Music Score Images by Instance Normalization

  • Tran, Minh-Trieu;Lee, Guee-Sang
    • Smart Media Journal
    • /
    • v.8 no.4
    • /
    • pp.64-71
    • /
    • 2019
  • The performance of an OMR (Optical Music Recognition) system is usually determined by the characterizing features of the input music score images. Low resolution is one of the main factors leading to degraded image quality. In this paper, we handle the low-resolution problem using the super-resolution technique. We propose the use of a deep neural network with instance normalization to improve the quality of music score images. We apply instance normalization which has proven to be beneficial in single image enhancement. It works better than batch normalization, which shows the effectiveness of shifting the mean and variance of deep features at the instance level. The proposed method provides an end-to-end mapping technique between the high and low-resolution images respectively. New images are then created, in which the resolution is four times higher than the resolution of the original images. Our model has been evaluated with the dataset "DeepScores" and shows that it outperforms other existing methods.

Resolution of Temporal-Multiplexing and Spatial-Multiplexing Stereoscopic Televisions

  • Kim, Joohwan;Banks, Martin S.
    • Current Optics and Photonics
    • /
    • v.1 no.1
    • /
    • pp.34-44
    • /
    • 2017
  • Stereoscopic (S3D) displays present different images to the two eyes. Temporal multiplexing and spatial multiplexing are two common techniques for accomplishing this. We compared the effective resolution provided by these two techniques. In a psychophysical experiment, we measured resolution at various viewing distances on a display employing temporal multiplexing, and on another display employing spatial multiplexing. In another experiment, we simulated the two multiplexing techniques on one display and again measured resolution. The results show that temporal multiplexing provides greater effective resolution than spatial multiplexing at short and medium viewing distances, and that the two techniques provide similar resolution at long viewing distance. Importantly, we observed a significant difference in resolution at the viewing distance that is generally recommended for high-definition television.

Optimal Resolution of L-Carnitine from Racemic DL-Carnitine by Enterobacter sp. Assimilating D-Carnitine

  • Hwang, Ki-Chul;Bang, Won-Gi
    • Journal of Microbiology and Biotechnology
    • /
    • v.7 no.5
    • /
    • pp.318-322
    • /
    • 1997
  • In order to isolate a microorganism having preferential degradation of D-carnitine from DL-carnitine, a bacterium assimilating D-carnitine as a sole carbon and energy source was isolated from soil by enrichment culture and partially identified as Enterobacter sp. Also, a mutant having lessened L-carnitine decomposition rates was selected with nitrosoguanidine mutagenesis, which led to decrease the specific activities of carnitine dehydrogenase (7.6-fold) and ${\beta}$-hydroxybutyrate dehydrogenase (9.5-fold) as compared to the wild strain. Meanwhile, optimal culture conditions for optical resolution of DL-carnitine were investigated. Under optimal conditions, 3.53 g/l L-carnitine was obtained from 20 g/l DL-carnitine, which corresponded to 35.3% L-carnitine yield and 97.9% optical purity.

  • PDF

Small scale Structure of Galactic Molecular Clouds toward Continuum Sources by KVN

  • Han, Junghwan;Yun, Young Joo;Park, Yong-Sun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.82-82
    • /
    • 2014
  • One of the subjects in clouds' structure and development is small scale structure of interstellar cloud. The possibility of AU scale structure (Marscher et al. 1993; Moore & Marscher 1995; Roy et al. 2012) is discussed, and this small scale structure is considered as the result of hydrogen volume density (Moore & Marscher 1995), or small-scale chemical and other inhomogeneities (Liszt & Lucas 2000). In order to study this subject with emission line, extremely high resolution is mandatory by VLBI system. However, the alternative method could be observing the absorption line of interstellar cloud on the continuum object. In this case, the resolution would be restricted to the size of the continuum object, if the size of the object is smaller than the resolution of a used telescope. We observed the previous researchers' three objects (BLLAC, NRAO150, B0528+138), whose spectrums are changed from 1993 to 1998 (Liszt & Lucas 2000), with KVN. Through KVN observation, we found the changes of optical depth spectrum compared with the previous spectrums. We will discuss the optical depth spectrum variation by time variation and the meaning of it.

  • PDF

SPACE SOLAR TELESCOPE

  • AI GUOXIANG
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.415-418
    • /
    • 1996
  • Space Solar Telescope (SST) is a space project for solar research, its main parameters are that total weight 2.0T, sun synchronous polar circular orbit, altitude of the orbit 730KM, 3 axis stabilized attitude system, power 1200W, telemetry of the downlink rate 30Mb/s, size $5{\ast}2{\ast}2\;M^3$, mission life 3 years. It is expected it will be launched in 2001 or later. The main objective is structure and evolution of solar vector magnetic field with very high spatial resolution. The payloads are consisted of 6 instruments: Main optical telescope with 1-M diameter and diffraction limited resolution 0.1 arc second, EUV imaging telescope with a bundle of four telescopes and 0.5 arc second resolution, spectrometric optical coronagraph, wide band spectrometer, H-alpha and white light telescope and solar and interplanetary radiospectrometer. An assessment study between China and Germany is under operation.

  • PDF

Vector control of Monorail PMSM traction motor using the hall-effect sensor (홀센서를 이용한 모노레일 PMSM 견인전동기의 벡터제어)

  • Son, Dong-Hyeok;Kim, Myoung-Su;Choi, Da-Woon;Cho, Yun-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1366-1370
    • /
    • 2010
  • This paper supposes the vector control algorithm to estimate the rotor position of permanent magnet synchronous traction motor using the hall-effect sensor. The hall-effect provides 60 electrical degrees resolution in rotor position sensing and it is very low resolution. The algorithm makes resolution high as optical encoders or electromagnetic resolver. If necessary, the reference rotor position angle is controlled by adjusting the variable. When a rotor position sensor such as either a optical encoder or a electromagnetic resolver is misalignment, it is useful to align with those. The method on adjusting the reference rotor position angle can compensate for misalignment error degrees by 60 electrical degrees.

  • PDF

High-Resolution Interrogation Technique for Fiber Bragg crating Sensor Using Long-Period Fiber Grating Pair and Erbium-Doped fiber

  • Jung, Jae-Hoon;Lee, Yong-Wook;Lee, Byoung-Ho
    • Journal of the Optical Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.5-12
    • /
    • 2002
  • A novel interrogation scheme to detect fine Bragg wavelength shift using a long period fiber grating pair with erbium-doped fiber inserted between the two gratings is reported. The technique is shown to feature high resolution and much more immunity to temperature perturbation compared to the conventioned Mach-Zehnder interferometer demodulation system. For quasi-static strain measurement, this approach provides high wavelength resolution of 0.05 pm that corresponds to 41.7 ne in strain and $3.8 $\times$ 10^{-3}$$^{\circ}C$ in temperature. This interrogation system is also employed in dynamic measurement to obtain the minimum detectable strain perturbation of ~ 8.76 ne/H $z^{{\frac}{1}{2}}$ at 100 Hz. Moreover, this interrogation system has prominent thermal stability. This thermal stability comes from the fact that two arms of the interferometer, the core and cladding in erbium-doped fiber, are exposed to nearly the same environment .

Resolution analysis of Fourier Hologram using integral imaging

  • Chen, Ni;Park, Jae-Hyeung;Kim, Nam
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.10a
    • /
    • pp.331-332
    • /
    • 2009
  • We present an analysis on the quality factors of the Fourier hologram generated from multiple orthographic view images of three-dimensional object. In the analysis, we analyze both the maximum size of the reconstructed object and its spatial resolution. For the maximum size of the reconstruction, we found that the main factor is the orthographic projection angle interval. Too large projection angle interval causes overlapping in the reconstruction space domain. For the spatial resolution, there are three factors, i.e. the capturing lens array pitch which determines the spatial sampling rate of the original three-dimensional objects, the maximum orthographic projection angle, and the spatial frequency bandwidth of the object. The dominant factor is determined by the relationship between those three factors.

  • PDF

High Resolution Photonic Force Microscope Using Resonance Energy Transfer

  • Heo, Seung-Jin;Kim, Ki-Pom;Cho, Yong-Hoon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.288-288
    • /
    • 2010
  • Photonic Force Microscope (PFM) is a scanning force microscope using an optical trap with several piconewton. In PFM, we can have topological information from the bead position trapped in optical trap. Typically the resolutions of lateral and vertical position are 40 nm and 50 nm respectively. To improve the vertical resolution below 10 nm, we use resonance energy transfer which has 5nm resolution in distance. Here we show preliminary results, including performances of scanning bead and fluorescence imaging system.

  • PDF