• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 0.034 seconds

The Analysis of Flow Circulation System for HANARO Flow Simulated Test Facility (하나로 유동모의 설비의 유체순환계통 해석)

  • Park, Yong-Chul
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.419-424
    • /
    • 2002
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality In February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. A flow simulation facility is being developed for the endurance test of reactivity control units for extended life times and the verification of structural integrity of those experimental facilities prior to loading in the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The flow circulation system is composed of a circulation pump, a core flow pipe, a core bypass flow pipe and instruments. The system is to be filled with de-mineralized water and the flow should be met the design flow to simulate similar flow characteristics in the core channel of the half-core test facility to the HANARO. This paper, therefore, describes an analytical analysis to study the flow behavior of the system. The computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with standard k-$\epsilon$ turbulence model and for the verification of the structural piping integrity through the finite element method. The results of the analysis are satisfied the design requirements and structural piping integrity of flow circulation system.

  • PDF

A study on thermal behavior of energy textile by performing in-situ thermal response test and numerical simulation (현장 열응답 시험과 수치해석을 통한 터널에 적용된 에너지 텍스타일의 열적 거동 연구)

  • Lee, Chul-Ho;Park, Moon-Seo;Min, Sun-Hong;Jeoung, Jae-Hyeung;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.325-335
    • /
    • 2010
  • A new geothermal energy source obtained from a tunnel structure has been studied in this paper. The geothermal energy is extracted through a textile-type ground heat exchanger named "Energy Textile" that is installed between a shotcrete layer and a guided drainage geotexitle. A test bed was constructed in an abandoned railway tunnel to verify the geothermal heat exchanger system performed by the energy textile. To evaluate the applicability of the energy textile, we measured the thermal conductivity of shotcrete and lining samples which were prepared in accordance with a common mixture design. An overall performance of the energy textile installed in the test bed was evaluated by carrying out a series of in-situ thermal response test. In addition, a 3-D finite volume analysis (FLUENT) was adopted to simulate the operation of the ground heat exchanger being encased in the energy textile with the consideration of the effect of the shotcrete and lining thermal conductivity.

  • PDF

Reliability Verification of Battery Disconnecting Unit (BDU 신뢰성 검증)

  • Yoon, Hye-Lim;Ryu, Haeng-Soo;Ji-Hong;Hong-Tae, Park
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.866-867
    • /
    • 2011
  • As part of the green growth, The Green Car has attracted wide attention. Types of the Green Car are Electric Vehicle, Plug-in Hybrid Electric Vehicle, Hybrid Electric Vehicle, Fuel Cell Vehicle and Clean Diesel Vehicle. Of these, The electric vehicle is equipped with the BDU(Battery Disconnecting Unit). BDU is supplying stable battery power and blocking it to protect electrical system of the electric vehicle. The BDU consists of electric components such as current sensor, fuse and pre-charge resistor. These must pass Voltage withstand test, Salt mist test, Thermal shock test, Vibration test and Short-circuit test commonly to verify reliability of the electric components. In addition, The current sensor should be verified whether normal operation. The breaking capacity of fuse should be verified. The durability of pre-charge resistor should be verified by supplying battery power and blocking it repeatedly. The reliability of BDU as well as the electric vehicle is secured by verifying the reliability of electric components. In addition, It will contribute to the acceleration and promotion of Green Car Technology.

  • PDF

Durability Evaluation of ER Fluids in Hydraulic Control Systems (유압제어시스템 적용을 위한 ER 밸브의 내구성 평가)

  • Kim, Do-Tae;Jang, Sung-Cheol
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.2
    • /
    • pp.100-105
    • /
    • 2007
  • Electro-rheological(ER) fluid and valve are fabricated and evaluated experimentally in its durability to utilize the hydraulic control systems for long term operation. The two-ports ER valve used in the experiment consist of twelve parallel multi-layer electrodes and provide a restriction to the passage of ER fluid because of the viscous pressure drop and a component induced by the electric field. The durability test of ER valve are performed by measuring the surface roughness of electrodes with variation of an electric field strength and test time(1000 or 1800min.). Also, the shear stress and shear rate are measured to evaluate the durability of ER fluid as function of time. After durability test, ER shear stress increases approximately proportional to the shear rate with applied electric field intensity, In the ER valve, the center line average height roughness(Ra) of copper electrode increases about 1.56 times and ten-point median height roughness(Rz) increases about 2.2 times after the durability test. An understanding of these durability is essential to predicting the service life of ER fluid and valves.

A Study on Electromagnetic Environmental Effects(E3) Test and Evaluation of Fighter Equipped with ELINT Pod (ELINT 포드를 장착한 전투기의 전자기 환경 영향(E3) 시험평가에 관한 연구)

  • Kim, In-Seon;Park, Young-Ju;Choi, Dae-Kyu;Kim, Jang-Pyo;Lee, Byeong-Nam
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.288-297
    • /
    • 2012
  • This paper describes the verification test on Electromagnetic Environmental Effects(E3), which conducted on ground as a final step to confirm the normal operation of ELINT pod and Safety-of-Flight of KF-16C/D mounted with ELINT pod prior to the initial flight. Based on MIL-STD-464A, indispensable 7 requirements among 14 detailed requirements total were carried out in the test. Considering the Safety-of-Flight(SOF), we invest a great deal of time and effort on Hazards of Electromagnetic Radiation to Ordnance(HERO) and Intra-system EMC test. E3 test and evaluation were performed on 62 equipments of KF-16C/D, respectively. As a result, we verify that KF-16C/D mounted with ELINT pod(hereafter "system") are electromagnetically compatible among all subsystems and equipment within the system and with environments caused by electromagnetic effects external to the system.

Balancing Technic Based on Rotor Dynamics Analysis of Test Rig (Test Rig 동특성 분석에 따른 밸런싱 기술 적용)

  • Hwang, Dukyoung;Jung, Chonwoo;Park, Insun;Shin, Dongmin;Song, Jinseok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.2
    • /
    • pp.204-212
    • /
    • 2017
  • The rotor dynamics and balancing technic for rotating equipment during engineering and manufacture stage are to be carefully considered in order to minimize the operation troubles regarding vibration during commissioning stage. In this paper, the test rig, which includes the disks as balancing plane, is designed and manufactured, so that the characteristic of rotor dynamics can be analyzed such as critical speed and mode shape. The critical speed predicted through natural frequency analysis is verified by the actual measurement on bearing housing vibration during start-up condition of test rig. The low speed balancing and the operating speed balancing test are performed respectively with consideration of first critical speed, and the residual unbalance amounts are estimated in accordance with the relevant method described in API standard. In addition, the single and dual plane balancing are carried out on main disk and trim disk depended on phase information at each balancing step.

Introduction to Construction of a Turbopump Real-Propellant Test Facility (터보펌프 실매질 시험설비 구축에 대한 소개)

  • Kim, Jin-Sun;Ko, Young-Sung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.835-840
    • /
    • 2011
  • The development of a turbopump is fundamental to have an independent LRE(liquid rocket engine) for KSLV-II. Recently, the detail design of a turbopump real-propellant test facility based on liquid oxygen and kerosene has been performed to structure the test facility for the experimental validation of the turbopump. In this paper, the design requirements of the turbopump and the specifications of the test facility was presented and the representative sub-facilities were explained on the basis of the design results. Also, the uncertainty of the sub-facilities which could be appeared during the operation was removed in advance through the simulation method and the experimental verification.

  • PDF

Simulation of the Distance Relay Using EMTP MODELS

  • J.Y. Heo;Kim, C.H.;R.K. Aggarwal
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.1
    • /
    • pp.26-32
    • /
    • 2004
  • Digital technology has advanced significantly over the years both in terms of software tools and hardware availability. It is now applied extensively throughout many area of electrical engineering including protective relaying in power systems. Digital relays have numerous advantages over traditional analog relays, such as the ability to accomplish what is difficult or impossible using analog relays. Although non real-time simulators like PSCAD/EMTDC are employed to test the algorithms, such simulations are disadvantaged in that they cannot test the relay dynamically. Hence, real-time simulators like RTDS are used. However, the latter requires large space and is very expensive. This paper uses EMTP MODELS to simulate the power system and the distance relay. The distance relay algorithm is implemented and the distance relay is interfaced with a test power system. The distance relay's performance is then assessed interactively under various fault types, fault distances and fault inception angles. The test results show that we can simulate the distance relay effectively and we can examine the operation of the distance relay very closely including its drawbacks/limitations by using EMTP MODELS. Equally important, this approach facilitates any changes that need to be carried out in order to enhance the Distance Relay under test/examination.

Airspeed Calibration of a Light Airplane via Flight Test (비행시험을 통한 경비행기의 속도계 보정)

  • Lee, Jung-Hoon;Yoo, Si-Yoong;Lee, Jang-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.7
    • /
    • pp.629-634
    • /
    • 2008
  • This paper presents the flight test procedure and the results for the airspeed indicator calibration of a light airplane the name of ChangGong-91, which is the first type certified aircraft from Korean Ministry of Construction and Transportation, as a part of the flight test validation to get the certification. The flight tests for airspeed position error calibrations are conducted using tower fly by method in order to calibrate swivel head testboom which is attached to the right wing tip of the airplane. Also system to system method is applied in order to calibrate the airspeed indicator of the cockpit. The flight test is conducted at the basis of the 'Korean Airworthiness Standard' which is the regulation of Korean Ministry of Construction and Transportation. The airspeed error range for the testboom and the airspeed indicator are determined to $-0.75{\sim}+0.75$ knot and to $-4.0{\sim}+2.0$ knots, respectively. The calibration results are applied to ChangGong-91 Flight Operation Manual.

A comparison analysis of the stem lubricant performance for motor operated valve used in nuclear power plants (원자력발전소에서 사용중인 모터구동밸브 스템 윤활유의 성능 비교 분석)

  • Kim, Dae-Woong;Kim, Yang-Seok;Park, Chi Young;Lee, Sang Guk
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.2
    • /
    • pp.6-12
    • /
    • 2015
  • In this study, the performance test was carried out under various operation conditions targeting four representing types of lubricant which are mostly used in nuclear power plants, and mutually compared the characteristic and performance of lubricant. Especially, introducing the concept of the thread friction coefficient (hereinafter, TFC), which makes the friction relation between the stem nut and stem screw dimensionless. The test was performed to compare the lubricant performance for the four kinds of lubricant (Texaco, Alvania, Mobilux, MOVLL). In a test of the room temperature stem, the TFC of MOV Long Life shows the lowest value, next to Alvania EP2, Texaco EP2, and Mobilux EP0 in that order. And in a test of the high temperature stem, the TFC of Texaco EP2 shows the lowest, next to MOV Long Life, Alvania EP2, and Mobilux EP0 in that order. From the test result of the aging condition, three types of lubricant (MOV LL, Texaco EP2, Alvania EP2) show similar patterns up to 36 months, but in 60 months, the TFC of lubricant are increased rapidly.