• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 0.028 seconds

Evaluation of the Menus of Free Meal Service Centers for Home-bound Elderly (재가노인들을 위한 무료급식소의 식단 평가)

  • Han, Kyung-Hee;Park, Jung-Sook;Choi, Mee-Sook;Chung, Soon-Dool;Chai, In-Sook
    • Journal of the Korean Society of Food Culture
    • /
    • v.17 no.5
    • /
    • pp.584-593
    • /
    • 2002
  • The purpose of this study was to evaluate the diet quality of the menus delivered by 17 free meal service centers for the low-income home-bound elderly in Chung- cheong buk-Do. Statistical data analysis was compleleted using the SPSS package program for descriptive analysis, T-test, and ANOVA. The meals offered by free meal service centers were not met the 1/3 recommended dietary allowances in calcium and vitamin $B_2$. There were significant differences between dependent variables(nutrient content, nutrient density, nutrient deficiency, NAR, MAR, food group intake patterns) and independent variables (operation type, operation status, operation period, nutritionist, food cost).

Autonomous SpeedSprayer Using Fuzzy Control

  • Cho, Seong-In;Ki, No-Hoon;Lee, Jae-Hoon;Park, Chang-Hyun
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.648-657
    • /
    • 1996
  • Autonomous speedsprayer operation in an orchard was conducted using a fuzzy logic controller (FLC). Orchard image analysis and signals of ultrasonic sensors were processed in real time. The speedsprayer was modified to be steered by two hydraulic cylinders. The FLC has two inputs of direction of running and distance from obstacles. Operation time of the hydraulic cylinders were inferred as output of the FLC. Field test results showed that the speedsprayer could be autonomously operated by the FLC along with the image processing and the ultrasonic sensors. The ultrasonic sensors didn't contribute to the improvement of guidance performance, but the speedsprayer could avoid trees or obstacles in emergent situations with them.

  • PDF

Investigation on the Lab Scale Corrugator's Optimum Operating Conditions for Making Microflute Corrugated Paperboards (마이크로플루트 골판지생산을 위한 실험용 코루게이터의 최적 운전조건 탐색)

  • Cho, Yong-Min;Um, Gi-Jeung
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.39 no.2 s.120
    • /
    • pp.54-59
    • /
    • 2007
  • Cereal, computer software, wine, small appliances, and fast foods are examples of products that have switched from folding carton to microflute corrugated paperboard. Microflute corrugated paperboards have their unique wonderful packaging characteristics that are driving forces for people to use more and more. Good strength property, excellent shock absorbing ability, and beautiful outer appearance of microflute corrugated paperboards go hand and hand with their environmental advantages. It is known that physical properties of microflute corrugated paperboards depend on not only properties of base paper but corrugator operating conditions. This study was carried out to investigate on the corrugator's optimum operating conditions for making micro flute corrugated paperboards. Lab-scaled micro flute corrugator was installed and run with systematic changes of operation conditions to investigate the effects of operation conditions on physical properties of micro flute corrugated paperboards.

A Comparative Study of Operation characteristics of Active Clamp Forward Converter Based on Loss Analysis (손실해석을 통한 능동 클램프 포워드 컨버터의 동작 특성비교)

  • Oh, Deog-Jin;Kim, Hee-Jun;Kim, Chang-Sun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2039-2041
    • /
    • 1998
  • In this paper, Operation characteristics of the active clamp(ACL) zero-voltage-switching(ZVS) forward converter(FC) and active clamp hard- switching(HS) forward converter are compared with respect to loss analysis. The losses of semiconductor (including conduction losses and switching losses), transformer(containing the core loss and copper loss) and parasitic element of passive element (capacitor, inductor) are measured and compared for each type. For an experiment we have built 50W ACL ZVS-FC and ACL HS-FC, in which the switching frequency is 200kHz, and test it. The experimental results show that both types of operation have nearly same characteristics.

  • PDF

Load-Adaptive Address Energy Recovery Technique for Plasma Display Panel

  • Lee Jun-Yeong
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2005.05a
    • /
    • pp.192-200
    • /
    • 2005
  • A high speed address recovery technique for AC plasma display panel(PDP) is proposed. By removing the GND switching operation, the recovery speed can be increased and switching loss due to GND switch also becomes to be reduced. The proposed method is able to perform load-adaptive operation by controlling the voltage level of energy recovery capacitor, which prevents increasing inefficient power consumption caused by circuit loss during recovery operation. Thus, th e technique shows the minimum address power consumption according to various displayed images, different from prior methods operating in fixed mode regardless of images. Test results with 50' HD single- scan PDP(resolution : $1366{\times}768$) show that less than 350ns of recovery time is successfully accomplished and about $54\%$ of the maximum power consumption can be reduced, tracing minimum power consumption curves.

  • PDF

A Study on Pump Down Operation Performance of Refrigerator (냉동기 펌프다운 운전성능에 관한 연구)

  • Kim, Chul-Soo;Chung, Han-Shik;Jeong, Hyo-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.964-970
    • /
    • 2006
  • Vapor compression refrigerators have much critical variables such as the controls of temperature and pressure switches, control durations and operating hours of electronic valves. This study compares and analyzes the data which is obtained from system controlling of the evaporation temperatures which are generally used in automatic pump down operating systems. Through this study, the automatic evaporation control operation system will be more ideal for the system to keep the proper temperature distribution depending on the purpose of evaporation side. The automatic pump down control operation is more appropriate for the system to aim at the effective use of evaporation side without using the temperature difference. And this test will be proved that the changes at the low pressure side didn't have significant impacts on the high pressure side.

Analysis of Indoor Temperature and Humidity Changes with the Operation of the Condense Drying Dehumidifier (가정용 제습기의 운전에 따른 실내 온습도 변화 분석)

  • Choi, Younhee;Song, Doosam;Sohn, Won-Woo;Lim, Younghoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.12
    • /
    • pp.626-632
    • /
    • 2015
  • The purpose of this paper is to analyze the indoor temperature and humidity changes with the operation of a condense drying humidifier. This paper illustrates the principles and composition of a condense drying dehumidifier, which is broadly used in Korean households. Experiments were conducted repeatedly on rainy days in a test chamber. The results showed that the indoor RH was lowered to 40% within 2 hours while the indoor temperature was increased by approximately $4.3^{\circ}C$ with the operation of the humidifier.

Local Path Planning Manager for Autonomous Navigation of UGV (무인차량의 자율주행을 위한 지역경로계획 매니저)

  • Lee, Young-Il;Lee, Ho-Joo;Park, Yong-Woon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.990-997
    • /
    • 2010
  • The Mission environment of UGV(Unmanned Ground Vehicle) has a complexity and variety, and the status of system and sensor is dependent on the environment factors such as operation time, the weather and road type. It is necessary for UGV to cope adaptively with the various mission types, operation modes and operation environment as human operators do. To satisfy this necessity, we present an autonomy manager based on the autonomous architecture. In this paper, we design a path planning software architecture and LPP manager by using open autonomous architecture which is previously designed by ADD. Field test is conducted with UGV in order to verify the performance of LPP Manager based on the Autonomous Architecture with scenarios.

Vibration Reduction for a Local Operation Panel Mounted by Wire Rope Isolator (Wire Rope Isolator 마운팅 수동 조작 패널의 진동 저감)

  • Kim, Chae-Sil;Kim, Dong-Il;Heo, Jong-Dae;Hwang, Jae-Deok
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.6
    • /
    • pp.127-133
    • /
    • 2014
  • This paper reviews a finite element model of a wire rope isolator (WRI) via an experimental comparison test. A local operation panel (LOP) mounted on a WRI is modeled using a finite element method. Mode analyses and harmonic analyses are conducted while varying of the thickness of the rope for the WRI. A feasible WRI can be selected considering the reduction of the vibration and the total weight of the LOP system.

Length-biased Rayleigh distribution: reliability analysis, estimation of the parameter, and applications

  • Kayid, M.;Alshingiti, Arwa M.;Aldossary, H.
    • International Journal of Reliability and Applications
    • /
    • v.14 no.1
    • /
    • pp.27-39
    • /
    • 2013
  • In this article, a new model based on the Rayleigh distribution is introduced. This model is useful and practical in physics, reliability, and life testing. The statistical and reliability properties of this model are presented, including moments, the hazard rate, the reversed hazard rate, and mean residual life functions, among others. In addition, it is shown that the distributions of the new model are ordered regarding the strongest likelihood ratio ordering. Four estimating methods, namely, method of moment, maximum likelihood method, Bayes estimation, and uniformly minimum variance unbiased, are used to estimate the parameters of this model. Simulation is used to calculate the estimates and to study their properties. Finally, the appropriateness of this model for real data sets is shown by using the chi-square goodness of fit test and the Kolmogorov-Smirnov statistic.

  • PDF