• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 0.036 seconds

The Effect of the Patient's Characteristics on Nursing Outcomes in Gastrointestinal Surgery Patients (간호결과에 대한 환자 특성의 영향 - 위장관계 수술 환자를 중심으로 -)

  • Lee, Byoung-Sook
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.14 no.3
    • /
    • pp.249-259
    • /
    • 2008
  • Purpose: This study was performed to identify the patient characteristics significantly affecting nursing outcomes and their predictability in gastrointestinal surgery patients. Method: The subjects were 149 abdominal surgery patients from 3 general surgical nursing units of 3 general hospitals. Two instruments were used to measure nursing outcomes and acuity of the subjects. The nursing outcomes were measured at post-operation 4 and 7days using review of patients' records, observation of patients, and interviews with patients by a trained nurse. For data analysis, T-test or ANOVA, Pearson Correlation and Stepwise Multiple Regression were done. Result: Age, severity score, diagnosis, cancer or not, operation site were the subjects' characteristics that were significantly related to the nursing outcomes in both post-operation 4 and 7days. Cancer or not, age, diagnosis and severity score were the significant predictors for the scores of nursing outcome in post-operation 4days and the predictability was 34.9%. The predictability of cancer or not was highest, 22.6%. Age, diagnosis and cancer or not were the significant predictors for the scores of nursing outcome in post-operation 7days and the predictability was 27.8%. The predictability of age was highest, 17.3%. Conclusions: The patient characteristics affecting nursing outcomes should be considered when nursing care is planned and provided. Especially, careful attention should be given to the patients with cancer and older age. And, these patient characteristics should be adjusted for correct estimation of the effectiveness of nursing interventions on nursing outcomes.

  • PDF

Application of Main Engine Turbocharger Cut-Out System Onboard a Vessel (Main Engine Turbocharger Cut-Out System 실선 적용 사례)

  • Cho, In-Young;Lee, Dong-Yeub;Kim, Young-Keon
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2011.09a
    • /
    • pp.36-38
    • /
    • 2011
  • As the increase of the fuel oil price, the demand for saving of the ship running cost is growing. To meet the needs of the shipowners, the method for low load operation has been developed by engine licenser. As one of low load operation, the turbocharger cut-out system can be utilized flexibly both full and part load operation. It can be possible to optimize fuel consumption at both full and part load operation. Tests by engine licenser with 12K98MC engine have proven that the fuel oil consumption can be reduced approximately 5%. In this paper we will study the application of main engine turbocharger cut-out system onboard a vessel. One of four turbochargers with MAN Diesel & Turbo 12K98MC-C and 12K98ME-C engine is cut out with swing gate valve. The fuel oil consumption is measured during sea trial and engine shop test.

  • PDF

An Accuracy Improvement on Acquisition Time of SCADA RTU Status Event (SCADA RTU 상태이벤트 취득시간 정확도 개선)

  • Lee, Ju-Heon;Lee, Sang-Joong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.3
    • /
    • pp.332-341
    • /
    • 2013
  • SCADA RTU is a remote control unit equipped in substations for automatic operation of a power system. The RTU monitors and measures the operation status of remote substations to transmits the signals to upper SCADA system and receives control command signals from dispatch center to actuate corresponding apparatus. The RTU receives the standard time from GPS receiver to synchronize the times for all devices and acquires the status event of power apparatus using DIM. Without the time synchronization between GPS and RTU, stable operation of the power system and accurate analysis of the system fault are impossible due to the time error of SOE. In this paper, a test is performed to identify if the operation time of SCADA RTU DIM coincides with the standard time. And we tried to find the reason of error, to minimize the time discrepancy. Through this study, RTU operation time could be synchronized with the standard time within 10[ms] to improve the reliability of SOE data.

An Dynamic Analysis of Quality Control in Korean Manufacturing Industry (한국제조기업 품질관리활동의 동적 분석)

  • 이순룡;이광재
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.10 no.16
    • /
    • pp.183-195
    • /
    • 1987
  • The effectiveness of quality control is contingent to adaptability to the present circumstance. The objectives of this study are to provide empirical data to carry out qualify control effectively. To accomplish this purpose, an empirical study was made by questionaire (mailing survey method, Feb. to Mar. in 1987). The sample is the 167 companies in Korean manufacturing industry. The main findings out of the analysis are as follows the stage of quality control is concentrated in appraisal phase, the company standard is equiped gradually in non-KS marked company and the need of economic evaluation about quality control is increased gradually. With a view to analysing of relationship between quality control and it's effect factors (company standard, KS mark, computer based information system), the methods of $\chi$$^2$ test are used. The company standard have a significant difference in top manager's altitude to duality control, operation stage of quality control. operation scope of qualify control and quality budgeting system but is insignificant with economic evaluation about duality control. Otherwise, KS mark is insignificant with the equality control activity except for operation scope. The quality information system based in computer have a significant difference in operation stage, operation scope and economic evaluation. Therefor, for the purpose of attaining effectiveness of quality control through the economic evaluation about quality control, the company standard and computer based duality information system must be utilized in quality control activity.

  • PDF

A Heuristic for the Operation Problem of the Vending Machine System (자판기 시스템 운영문제의 휴리스틱 해법 개발과 평가)

  • Park, Yang-Byung;Jang, Won-Jun;Park, Hae-Soo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.34 no.4
    • /
    • pp.152-161
    • /
    • 2011
  • The operation of vending machine system presents a decision-making problem which consists of determining the product allocation to vending-machine storage compartments, replenishment intervals of vending machines, and vehicle routes, all of which have critical effects on system profit. Especially, it becomes more difficult to determine the operation variables optimally when demand for a product that is out-of-stock spills over to another product or is lost. In this paper, we propose a heuristic for solving the operation problem of the vending machine system and evaluate it by comparing with Yang's algorithm on various test problems with respect to system profit via a computer simulation. The results of computational experiments show a substantial profit increase of the proposed heuristic over Yang's algorithm. Sensitivity analysis indicates that some input variables impact the profit increase significantly.

Study of combinations of site operating states for multi-unit PSA

  • Yoo, Heejong;Jin, Kyungho;Heo, Gyunyoung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3247-3255
    • /
    • 2021
  • As Probabilistic Safety Assessments (PSAs) are thoroughly conducted for the Site Operating States (SOSs) for a single unit, multi-unit Probabilistic Safety Assessments (MUPSAs) are ongoing worldwide to address new technical challenges or issues. In South Korea, the determination of the site operating states for a single site requires a logical approach with reasonable assumptions due to the fact that there are 4-8 operating units for each site. This paper suggests a simulation model that gives a reasonable expectation of the site operation states using the Monte-Carlo method as a stochastic approach and deterministic aspects such as operational policies. Statistical hypothesis tests were conducted so that the reliance of the simulation results can be guaranteed. In this study, 7 units of the Kori site were analysed as a case study. The result shows that the fraction of full power for all 7 units is nearly 0.45. For situations when more than two units are not in operation, the highest fraction combination was obtained for Plant Operation State (POS) 8, which is the stage of inspection and repairment. By entering various site operation scenarios, the simulation model can be used for the analysis of other site operation states.

Preventing Mobile Game Client Memory Manipulation Based on Event Sourcing Patterns and Blockchain (이벤트 소싱 패턴과 블록 체인을 활용한 모바일 게임 클라이언트 메모리 조작 방지 방안)

  • Park, Jihun;Park, Young-Ho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.32 no.3
    • /
    • pp.477-486
    • /
    • 2022
  • This study aims to present a method using event sourcing patterns and blockchain as a way to cope with vulnerabilities in memory manipulation at the client level. To verify the plan, the method of running the memory operation application was analyzed, and the performance was compared and analyzed when the memory operation prevention plan was applied by fabricating a test application. As a result of the analysis, the usage of memory increased compared to the method of XOR operation by storing major data in one memory, but it was possible to prevent the operation of the memory operation program without significantly affecting the performance of the game.

Operation result of the Cryogenic and Mechanical Measurement System for KSTAR (KSTAR 저온 및 구조 계측 시스템 운전 결과)

  • Kim, Y.O.;Chu, Y.;Yonekawa, H.;Bang, E.N.;Lee, T.G.;Baek, S.H.;Hong, J.S.;Lee, S.I.;Park, K.R.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.26-30
    • /
    • 2009
  • Korea Superconducting Tokamak Advanced Research(KSTAR) device is composed of 30 superconducting magnets, magnet structure, vacuum vessel, cryostat, current feeder system, and etc. KSTAR device is operated in the cryogenic temperature and high magnetic field. We install about 800 sensors - temperature sensors, stain gages, displacement gages, hall sensors - to monitor the thermal, mechanical, electrical status of KSTAR during operation. As a tremendous numbers of sensors should be installed for monitoring the KSTAR device, the method of effective installation was developed. The sensor test was successfully carried out to check its reliability and its reproduction in the cryogenic temperature. The sensor signal is processed by PXI-based DAQ system and communicated with central control system via machine network and is shown by Operator Interface(OPI) display in the main control room. In order to safely operate the device, any violations of mechanical & superconductive characteristic of the device components were informed to its operation system & operator. If the monitored values exceed the pre-set values, the protective action should be taken against the possible damage. In this paper, the system composition, operation criteria, operation result were presented.

A study on the Multibody Dynamics Simulation-based Dynamic Safety Estimation for Installation and Operation of A-Frame in Retrofit Vessel (개조 선박의 A-Frame 설치 및 운용을 위한 다물체 동역학 시뮬레이션 기반 동적 안전성 검토에 관한 연구)

  • Oh, Jaewon;Kim, Hyungwoo;Kwon, Osoon;Kang, Hyoun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.5
    • /
    • pp.789-798
    • /
    • 2020
  • This paper considers the development of the dynamic analysis model and simulation-based operation safety estimation of A-Frame to be applied to the test evaluation support vessel for real sea test. The support vessel will be manufactured by modifying the existing offshore support vessel. Also, development and installation of various sensors and supporting facilities for test evaluation are under preparation. Among these facilities, A-Frame is an equipment that transfers marine equipment from ship deck to the sea floor, and is being designed to transfer up to 50 ton class equipment. However, the A-Frame is a moving equipment using hydraulic cylinders. When the 50 ton equipment is attached and transferred to A-Frame, the buckling of cylinders may occur or A-Frame becomes inoperable due to the influence of huge inertia. For this reason, safety verification should be performed using dynamic analysis techniques that can take into account huge inertia forces in the design of A-Frame. Therefore, in this study, A-Frame and ship behavior were modeled using dynamic analysis method, and the applied loads of various equipment including hydraulic cylinder of A-Frame was measured and the operation safety review was performed.

A study on the Normal Steady State Operation Characteristics of PV System Based on the Test Device (태양광전원용 시험장치를 이용한 정상상태 운용특성에 관한 연구)

  • Hasan, Md.Mubdiul;Munkbaht, Munkbaht;Kim, Byung-Ki;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.512-516
    • /
    • 2012
  • Recently the Korean government's green energy growth policy has been taken at the national level due to the sufficient supply of renewable energy. Some specific technique should be taken in consideration for the operation of the grid voltage and power quality management. In this case, there may have some chance of operational problems. Typical problems arise when grid-connected solar power produced by Pacific sunshine. The power flow in the reverse direction can create overvoltage on the distribution line and gives value of malfunction on the system. Line voltage and overvoltage adjustment practice can stop these symptoms occurred. Under these circumstances, this paper presents an interconnection test devices for photovoltaic(PV) systems composed of distribution system simulator, PV system simulator and control and monitoring systems using the LabVIEW S/W, and simulates the customer voltage characteristics considering the 3 parameters on the introduction capacity for PV systems, system configuration and Power factor. This paper also proposes a new calculation algorithm for voltage profile to make comparison between calculation values and test device values. The results show that the simulation results for the normal operation characteristics of PV systems which are very practical and effective.

  • PDF