• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 0.032 seconds

A Study on Development of the High-Power Low-Loss Waveguide Circulator for Ka-band Millimeter-Wave Seeker (밀리미터파대역(Ka-대역)탐색기용 고 전력 저 손실 도파관 순환기 개발에 관한 연구)

  • Jung, Chae-Hyun;Han, Sung-Min;Baek, Jong-Gyun;Lee, Kook-Joo;Park, Chang-Hyun;Kwon, Jun-Beom
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.6
    • /
    • pp.83-88
    • /
    • 2017
  • In this paper, a 3-port waveguide circulator of Ka-band millimeter-wave for isolation between transmit channel and receive channel at high power transmit mode is designed and fabricated for the seeker of the guided missile and circulator performance is verified through the S-parameter, high power and operation temperature test. At the configuration design, interface design between a seeker antenna and the circulator is considered and half-height of standard waveguide is applied for minimum and light weight body. The shape of permanent magnet and ferrite is optimized by simulation and tuning dielectrics at each port are placed for the best performance. In Fc(center frequency)${\pm}1000MHz$, designed waveguide circulator has below -20 dB return loss, below 0.5 dB insertion loss and below -23 dB isolation. It is found that circulator characteristics is similar to design results.

Comparative Study on the Tooth Mobility after Modified Widman Flap (변형 Widman 판막술 후 치아 동요도 변화에 관한 연구)

  • Kim, Soo-Yong;Chung, Chin-Hyung;Lim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.1
    • /
    • pp.103-111
    • /
    • 2003
  • Tooth mobility is an important part of a periodontal examination and represents a function of the persisting height of the alveolar bone and the width of the periodontal ligament. The purpose of this study was to evaluate the changes of the tooth mobility over 4 week-period following surgical therapy on the periodontal disease. Thirty five patients presenting with moderate periodontal pockets were selected and tooth mobility was measured at weekly intervals using Periotest (Siemens Co., Germany) beginning at the pre-operation examination and ending four weeks following the modified Widman Flap. All data were statistically analyzed using the one-way ANOVA test. The results were obtained as follows; 1. All teeth exhibited the greatest change in mobility at 1 week post-op, mobility generally decreasing with time. 2. Comparison of the weekly tooth mobility data regarding the 1st premolars showed significant differences only between weeks 1 (9.94) and 4 (6.14) (p<0.05). 3. Comparison of the weekly tooth mobility data regarding the 1st molar showed significant changes in the intervals between pre-op (6.49) and week 1 (11.22), pre-op and week 2 (9.37), weeks 1 and 3 (7.65), weeks 1 and 4 (5.62), and weeks 2 and 4 (p<0.05). 4. Comparison of the weekly tooth mobility data regarding the 2nd premolar and 2nd molar showed significant differences between pre-op (6.91, 8.60) and week 1 (11.02, 12.62), weeks 1 and 3 (8.00, 8.05), weeks 3 ad 4 (6.22, 6.71), and weeks 2 (9.34, 11.01) and 4 (p<0.05).

The Study of Malodor Reduction after Periodontal Treatment (치주질환 치료 후 구취 감소에 대한 연구)

  • Lee, Jae-Myung;Lim, Sung-Bin;Chung, Chin-Hyung;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.2
    • /
    • pp.449-459
    • /
    • 2004
  • Bacterial byproducts and volatile sulfur compounds(VSC) have been found to be the leading intra-oral agents, specifically, the byproducts of gram negative anaerobic bacteria have been implicated as primary factors of halitosis in patients presenting with periodontal disease. The objective of this study was to determine the correlation between periodontal treatment and the subsequent reduction in the level of halitosis. Forty-three subjects presenting with periodontal disease were examined before periodontal treatment, one week after treatment, one month after treatment, and finally, two months after treatment, using a portable sulfide monitoring $Halimeter^{(R)}$ to measure the VSC concentrations at the prescribed intervals. The results of the study were as follows: 1. Significant decreases in the mean VSC concentration were observed at the one week, one month, and two month post-op intervals relative to the pre-op measurement. (p<0.05) 2. Significant decreases in the mean VSC concentration were observed in subjects after completion of flap operations. Significant decreases in the mean VSC concentration were observed at the one and two month post-flap operation measurement relative to the VSC concentration at one week (p<0.05), but no significant differences between the one month and two month VSC concentrations were found. (p<0.05) 3. Significant decreases in the mean VSC concentration were observed in subjects after completion of subgingival curettage (p<0,05). Significant decreases were found between the one week and one month measurements and between the one month and two month measurements, but significant differences were not observed between the one week and two month measurements. (p<0.05) The results of this study show significant decreases in VSC concentration in test subjects after periodontal treatment. It can be inferred from the results above, that periodontal disease is a significant contributing factor of halitosis, and that treatment of periodontal disease can been an effective means of reducing VSC concentration in patients presenting with halitosis concurrent with periodontal disease.

The Development of US Navy's Maritime Strategy and the ROK's Tasks with a Focus on the Roles of Aircraft Carrier (미(美) 해군의 해양전략 발전과 우리의 과제 - 항모운용을 중심으로 -)

  • Kwon, Young-Il
    • Strategy21
    • /
    • s.41
    • /
    • pp.30-51
    • /
    • 2017
  • Neighboring powers in the Korean Peninsula have started to develop and operate aircraft carriers or equivalent forces to cope with rising North Korean nuclear and missile threats and also to show its national might. For example, the United States has added a aircraft carrier from the 3rd fleet to western pacific theater of operation, while Peoples Republic of China is undergoing operational test of Liaoning as well as preparing for christening of its 2nd aircraft carrier. Japan is flexing its muscle as well by deploying Izumo capable of operating F-35B to Southeast Asia to participate in multilateral exercises starting this year. It is a high time to know more about aircraft carriers or similar types in terms of maritime strategy and history. The U.S. has had by far the vast amount of experiences in utilizing aircraft carrier that it would be beneficial for us to examine U.S. perspectives and its application in the Korean Peninsula. It will provide us with insights to understand and predict what it would be like in times of crisis in the Korean Peninsula in the perspective of aircraft carrier's involvement. This paper intends to show some aspects of future conflicts in the Korean Peninsula and how the ROK Navy can best be ready for such situation. For research purpose, U.S. maritime strategy has been developed in stages ; establishment phase, WWI phase, WWII phase, Cold war phase, post Cold war phase. Each phase includes such factors as threats, strategic concept, applications, and ways to improve maritime strategy. Finally, the role of aircraft carrier based on past history as well as future conflict shines the importance to have power projection capabilities for the ROK Navy. The intrinsic nature of the navy in the world is to project power ashore just as history proved it.

A Study on the Hybrid Fuel Cell System by using supercapacitor (수퍼커패시터를 이용한 하이브리드 연료전지시스템에 관한 연구)

  • Yoon, Seong-Sik;Choi, Won-Muk;Kim, Sung-Hoon;Kim, Tea-Kue;Ahn, Ho-Gyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.589-592
    • /
    • 2011
  • In this paper, bidirectional DC-DC converter is designed to cover up defects of fuel cell generating system like as low dynamic characteristic, unstable output and lack of storage ability by using bidirectional DC-DC Converter and supercapacitor that available to charge & discharge quickly, high efficient at charge & discharge and semi-permanent. Operating efficiency has been analyzed through simulation and examination. According to these design and data, hybrid system has been made and operation test, evaluation and results evaluation have been performed.

  • PDF

The performance evaluation of the polymer arm insulator for a compact transmission line tower (친환경적인 컴팩트 송전탑용 폴리머 절연암의 성능평가에 관한 연구)

  • Song, Hong-Jun;Park, Gi-Ho;Kim, Gwan-Hyung;Byun, Gi-Sik;Hwang, Yeong-Yeun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.2
    • /
    • pp.341-347
    • /
    • 2009
  • As a right-of-way security for the high power transmission line tower construction is becoming more and more difficult, the friendly environmental compact tower design is required. For a proper insulation for the compact tower, the polymer material are being tried. Some countries has already adapted, in the various polymer application and management data, polymer arm insulator to the transmission tower, and shown a stable operation. However, in our country, the polymer arm insulator has left much to be desired in the installation on the transmission line tower. But polymer material has been developed by high strength and technology and is expected to be used in various electric equipments. The polymer arm insulator is a one of good electric insulation materials to expand the power supply capacity in the rapid power demand increasement In this research, the new polymer am insulator is designed and its electric specifications are analyzed. Its mechanical specifications is verified through the field test on the compact tower which is modified by the polymer arm insulator.

A Study on the High-power Low-loss Dual Axes Waveguide Rotary Joint for Ka-Band Millimeter-Wave Small Radar (밀리미터파대역(Ka-대역)소형 레이더용 고 전력 저 손실 2축 도파관 로터리 조인트 연구)

  • Jung, Chae-Hyun;Sung, Jong-Hyun;Baek, Jong-Gyun;Lee, Kook-Joo;Park, Chang-Hyun;Kwon, Jun-Beom
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.1
    • /
    • pp.91-96
    • /
    • 2018
  • In this paper, dual axes waveguide rotary joint, which operates at high power and has low loss characteristic, is designed and fabricated for a Ka-band millimeter-wave small radar. Its electrical performance is verified through the S-parameter at room temperature, high power and operation temperature test. Rotary joint functionally consists of the mode converter transforming rectangular waveguide into circular waveguide and the choke at the rotation part. At the configuration design, linking a fixed transmitter to an antenna rotating dual axes electrically for minimum loss and light weight body are considered. In Fc(center frequency)${\pm}500MHz$, the designed rotary joint has VSWR 1.5:1 below return loss, -2.0 dB above insertion loss. It is found that rotary joint characteristics is similar to design results.

A case study for installing of Energy Metering Systems in an Office Building (사무소 건물의 에너지 미터링 시스템 구축에 관한 사례연구)

  • Han, Hye-Sim;Lee, Na-Eun;Lee, Jin-Sook;Jeong, Hak-Geun;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.51-57
    • /
    • 2013
  • Energy saving starts by knowing how much energy is being consumed. A building factor is easier than any other things in energy saving. Since, especially, it is closely connected with user's space-use-patterns and manager's utility-operation-style. An energy metering system lets building users know about energy consumption pattern in buildings and measure energy in real time. Development and materialization of metering systems need more careful plans, so that they depend on a demand of individual facilities and available infrastructures they used to use. But, so far, there is no guidelines how to install metering systems. This paper suggested how to install meters and researched a method for how to analyze by using metered data. For that, Green Building in KIER is used as a test bed. As the results, nevertheless the smallest number of meters is basically one for the whole building energy measuring, it is too limited in analysis. So we needed to add the sort of fuel and utility types and found that it depends on all cases. For this reasons, a guideline should be created in order to install meters as soon as possible. It would be suggest a way to save more energy in building factor.

The Ejector Design and Test for 125 kW Class Molten Carbonate Fuel Cell System (125 kW급 용융탄산염 연료전지 시스템의 이젝터 설계 및 시험)

  • KIM, BEOMJOO;PARK, SOO-MAN;SONG, OH-SEOP
    • Journal of Hydrogen and New Energy
    • /
    • v.29 no.2
    • /
    • pp.139-147
    • /
    • 2018
  • Korea Electric Power Research Institute (KEPCO RI) had developed molten carbonate fuel cell (MCFC) system since 1993. Finally, KEPCO RI developed and operated a 125 kW MCFC system in 2010. To make MCFC system compact, it is indispensable to install an ejector in this system where the anode off gas, the cathode off gas, and fresh air are mixed before flowing to the catalytic burner. KEPCO RI had developed various ejectors for MCFC system since 2006. The 125 kW MCFC system built with the developed ejector was operated successfully in Boryeong Thermal Power Plant in 2010. This 125 kW MCFC ejector was designed on the basis of the experimental results of 5 kW and 75 kW MCFC ejectors. The main goal of ejector design in our MCFC system is to maintain the entrainment ratio and the pressure between fuel cell stack and catalytic burner within the operating range. In this paper, the design results of the ejector are presented based on the 125 kW MCFC system operating conditions. In addition, a designed ejector was manufactured and installed in the MCFC system. As the fuel cell is under load operation, the pressure surrounding the ejector was measured to ensure that the fuel cell system is operating smoothly.

A Study on Measurement Parameters of Virtualized Resources on Cloud Computing Networks (클라우드 컴퓨팅 네트워크에서 가상화 장비 평가 항목 연구)

  • Lee, Wonhyuk;Park, Byungyeon;Kim, Seunghae;Kim, TaeYeon;Kim, Hyuncheol
    • Convergence Security Journal
    • /
    • v.14 no.7
    • /
    • pp.85-90
    • /
    • 2014
  • Cloud computing originated simply to request and execute the desired operation from the network of clouds. It means that an IT resource that provides a service using the Internet technology. It is getting the most attention in today's IT trends. In cloud computing networks, devices and data centers which are composed of the server, storage and application are connected over network. That is, data of computers in different physical locations are integrated using the virtualization technology to provide a service. Therefore cloud computing system is a key information resource, standardized methods and assessment system are required. In this paper, we aims to derive the parameters and information for research of technical standards stability evaluation method associated with various cloud computing equipment.