• 제목/요약/키워드: operation reliability

검색결과 2,116건 처리시간 0.03초

신뢰성 분석을 위한 Function Tree 및 Fault Tree 구성 방법에 관한 연구 (A Methodology for Constructing Function Tree & Fault Tree in Reliability Analysis)

  • 하성도;이언경;강달모
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집C
    • /
    • pp.333-338
    • /
    • 2001
  • Fault tree is a widely used methodology for analyzing product reliability. The fault trees are usually constructed using the experiences of expert reliability engineers in top-down approaches and have different structures according to each expert's subjectivity. In this work it is tried to find a general method for the fault tree construction based on the function tree that is the result of product function deployment. Based on the function tree, the method has the advantage of resulting an objective fault tree since the faults are defined as the opposite concept of functions. The fault tree construction of this work consists of the following steps: 1) definition of product primary function with the viewpoints of product operation and configuration, 2) construction of functional relation chart using a grouping algorithm, 3) abstraction of functional block diagram according to operation sequences and configuration of a product, 4) construction of function tree for each viewpoint, and 5) construction of fault tree by matching the function tree and simplification of the result.

  • PDF

내부고장을 고려한 고온형 연료전지 대규모 발전단지의 병렬운전 변압기 적정 뱅크수에 관한 연구 (A Study on the Proper Number of Banks of Parallel Operation of Transformer in Large-scale Power Plants Using the High Temperature Fuel Cell Considering the Internal Failure)

  • 정영환;채희석;성인제;김재철
    • 조명전기설비학회논문지
    • /
    • 제28권3호
    • /
    • pp.26-31
    • /
    • 2014
  • High temperature fuel cell system, such as molten carbonate fuel cells(MCFC) and solid oxide fuel cells(SOFC), are capable of operating at MW rated power output. The power output change of high temperature fuel cell imposes the thermal and mechanical stresses on the fuel cell stack. To minimize the thermal-mechanical stresses on the stack and increase the systems reliability, we should divide the power plant configuration to several banks. However, the improvement of reliability in fuel cell power plant system causes an increase of the investment cost, for example, replacement costs, labor costs, and so on. For this reason - the balance between investment and reliability improvement - many studies about the appropriate level of investment have been conducted. In this paper, we evaluate the cost for operation and installation, the benefit for electric energy and thermal energy sales, and the system reliability for several cases : these cases relate with the bank configuration.

소프트 에러에 대한 캐쉬 메모리의 태그 비트 신뢰성 향상 기법 (Reliability Improvement of the Tag Bits of the Cache Memory against the Soft Errors)

  • 김영웅
    • 한국인터넷방송통신학회논문지
    • /
    • 제14권1호
    • /
    • pp.15-21
    • /
    • 2014
  • 반도체 공정 기술의 발달로 인하여 프로세서 내에 적재할 수 있는 캐쉬 메모리의 용량은 증가하였지만 높은 트랜지스터 집적율은 프로세서를 소프트 에러에 대해 더 취약하게 만들었으며, 이는 설계 고려사항 중 신뢰성의 비중이 점점 더 높아짐을 의미한다. 이러한 취약성을 극복하기 위하여 캐쉬 메모리의 데이터에 대한 다양한 신뢰성 기법이 제안되었으나, 태그 비트에 대한 연구는 제한적이다. 본 연구는 캐쉬 메모리 중 태그 비트에 대해 Temporal Locality 특성을 만족하지 않는 write-back 동작에 대한 보호율을 분석하고, 이를 극복할 수 있는 방안을 제안한다. 실험을 통해 제안된 기법으로 기존의 write-back에 대한 보호율을 59.0%에서 76.8%까지 성능 저하 없이 증가시킬 수 있다.

국내 전력계통 신뢰도 기준을 위한 전압 제한범위 결정에 관한 연구 (A Study on the Determination of Voltage Limits for Korean Power System Reliability)

  • 벤지마플로레스;드위리아나아리아니;김승진;송화창
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.335-336
    • /
    • 2015
  • Voltage collapse is one of the main threats in power system operation and it is a result of a very low voltage profile in one or multiple areas in the power system network. Hence, the need for proper coordination among transmission and generator operators to maintain voltage stability if of paramount importance. In this paper, the different voltage and reactive power operating guidelines and criteria of various electric reliability councils, coordinating councils, transmission system operators and other electric utilities are discussed. Among these are NERC, ENTSO-E, WECC, PJM and ERCOT. A comprehensive comparison is also made to the existing Korean power system voltage reliability guidelines. Furthermore, this paper presents a set of voltage and reactive power guidelines that can help in determining voltage limits that can improve the reliability of the Korean power system operation.

  • PDF

지속 감항성 유지 프로그램 운영 경험의 항공기 설계와 인증 단계 적용 (Application of Operational Experience of the Continuous Airworthiness Program at the stage of Aircraft Design and Certification)

  • 구민성
    • 한국항공운항학회지
    • /
    • 제21권3호
    • /
    • pp.9-14
    • /
    • 2013
  • Continuous airworthiness system is comprised of regulations and procedures to assure the safety and reliability through the total stage of development, certification and operation of aircraft. The purpose of this system is not only to provide the guidelines that should be kept by manufacturers and operators, but also to evaluate the maintenance capability in every activity of safety related procedures. During the development process of the mid and large size aircraft, operational experience should be reflected systematically for a safer and more reliable product by using the meaningful data base from operation. The relationship of safety roles between manufacturer and operator is mutually complementary, and the roles of each function have an influence to the next step. Overall structure of the procedure contains the concept of continuous analysis and feedback to achieve highest degree of safety and reliability during the entire life of aircraft. Finally, this paper describes how the feedback is made and used for aircraft design from operational experience under the continuous analysis and surveillance system.

국산훈련기 신뢰성기반 정비주기 연장방안 연구 (A Study for Maintenance Period Extension based on Reliability of Korea Trainer)

  • 조인탁;박종훈
    • 산업경영시스템학회지
    • /
    • 제43권4호
    • /
    • pp.123-132
    • /
    • 2020
  • Currently, there are two types of trainer in Korea : basic and advanced. Both models have been in operation for more than 10 years, and compared to the early stage of operation, reliability has gradually improved and failure rates have also entered a trend of stabilization. Therefore, it is necessary to extend the maintenance period considering economic feasibility. This study investigates the three maintenance period calculation methods: NAVAIR 00-25-403 [17], DOD, U.S. [4], CERL and US Army [3], with intention to extend the maintenance period of the trainer from current 200 hours to 400 hours. In addition, the maintenance period was calculated by the three methods with actual operational data. Common standards and procedures were established to apply operational data to the existing maintenance period calculation methods, the required reliability indicators were derived, and the maintenance periods was calculated based on the results, additionally, a review on the field applicability of the three maintenance cycles was conducted. An on-site interviews were conducted with the calculation results, and 11 out of the 15 items were expected to be extended by 400 hours. It was suggested that the remaining 4 items could be extended to 400 hours by supplementing the inspection method through additional analysis such as functional analysis, inspection content verification, and site connection.

보일러-터빈 제어시스템의 측정기 고장검출 (A Sensor Fault Detection for Boiler-Turbine Control System)

  • 류석환
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제14권1호
    • /
    • pp.37-43
    • /
    • 2014
  • This paper deals with a design of observer based fault detection filter for a boiler-turbine control system. The goal is to present a method for rapid sensor fault detection in order to enhance the reliability of boiler-turbine operation in the thermal power plant. Our fault detection filter can be designed via solutions of linear matrix inequalities. In order to demonstrate the efficacy of our design method, numerical simulations are provided.

신뢰성기반 제품경쟁력 결정요인 선정방안 (Choice method of Competitive Power Key Factors based on Reliability)

  • 김종걸;빈성욱
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2004년도 추계학술대회
    • /
    • pp.259-267
    • /
    • 2004
  • Enterprise must establish a properly competitive strategy according to environmental changes and international competitions. It is necessary to develop the strategy of competitive power for an efficient operation as well as system, industry, product and price competitions. This paper aims to propose a choice method of Competitive Power Key Factors which can be applied to unit parts and finished products, construction products, soft wear products based on Reliability.

  • PDF

Multivariate Mean Inactivity Time Functions with Reliability Applications

  • Kayid, M.
    • International Journal of Reliability and Applications
    • /
    • 제7권2호
    • /
    • pp.127-140
    • /
    • 2006
  • AIn this paper we introduce and study a multivariate notions of mean inactivity time (MIT) functions. Basic properties of these functions are derived and their relationship to the multivariate conditional reversed hazard rate functions is studied. A partial ordering, called MIT ordering, of non-negative random vectors is introduced and its basic properties are presented. Its relationship to reversed hazard rate ordering is pointed out. Finally, using the MIT ordering, a bivariate and multivariate notions of IMIT (increasing mean inactivity time) class is introduced and studied.

  • PDF

신뢰성분석 기법을 이용한 고속철도 검측시스템의 수명예측 (Lifetime Prediction Using Reliability Analysis Method about for the Electric Detection System)

  • 이현우;이병곤;이충한
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제14권3호
    • /
    • pp.191-196
    • /
    • 2014
  • The importance of railway safety has become increasingly significant domestically as well as internationally, as a series of high speed railway accidents and other major accidents have occurred recently. Especially for the domestic railway, the Korean Railway Safety Law has been revised recently, mandates all the domestic railway operation authorities to render the performance of RAMS and RCM. This study inspects and analyzes the current status of the sensing technology of the electric detection system to tell the status of railway facilities in the highway railway in a real time through a sensor. It also performs the reliability analysis of the electric detection system that is being progressed as a study assignment and suggests the system construction for the higher reliability.