• 제목/요약/키워드: operating current

검색결과 3,342건 처리시간 0.03초

Impact of Current Density, Operating Time and pH of Textile Wastewater Treatment by Electrocoagulation Process

  • Hossain, Md. Milon;Mahmud, Md. Iqbal;Parvez, Md. Shohan;Cho, Haeng Muk
    • Environmental Engineering Research
    • /
    • 제18권3호
    • /
    • pp.157-161
    • /
    • 2013
  • Treatment of textile wastewater by the electrocoagulation (EC) process is being investigated by this experimental study. The objective of this experiment is to observe the efficiency of the EC process in removing chemical oxygen demand (COD) and turbidity. In this experiment an iron electrode is used in the EC process, and different working parameters such as pH, current density and operating time were studied in an attempt to achieve a higher removal capacity. The results show that the maximum COD removal occurred at neutral pH at operating time 30 min. COD and turbidity removal reaches at maximum, with optimum consumption of electrodes, between current density 85-95 $A/m^2$, and only trace amounts of metals were determined in the EC treated effluent.

HTS 전동기용 계자코일의 자장 특성 연구 (A Study of Magnetic Field Characteristic of Field coil in HTS motor)

  • 이정종;조영식;홍정표;손명환;김석환;권영길
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권2호
    • /
    • pp.47-51
    • /
    • 2002
  • In this paper, flux distribution and operating current is calculated according to the field coil change in HTS(High Temperature Superconducting) motor. In order to calculate magnetic field characteristic of the field coil. it is computed by changing the outer radius and the inner width of field coil Bio-Savart equation is used as the analysis method for the characteristic analysis of magnet. 2D and 3D FEA(Finite Element Analysis) is used for the magnetic field distribution in HTS motor The operating current is calculated by $B{\bot}$ linked With the field coil and $I_c-B curve of superconductor.

새로운 3상 준공진 직류링크 인버터 (A Novel Three-Phase Quasi-Resonant DC Link Inverter)

  • Lee, Jin-Woo;Park, Min-Ho;Won, Jong-Soo
    • 대한전기학회논문지
    • /
    • 제40권5호
    • /
    • pp.479-488
    • /
    • 1991
  • A novel three-phase quasi-resonant dc link inverter (QRI)with a switch connected between dc voltage source and resonant inductor is proposed. According to the state of switching and load current, the operating mode of the proposed inverter scheme is classified into free-wheeling, inverting, and rectifying mode. By examining the behavior of the circuit in each operating mode, an equivalent circuit which represents all the modes in a unified manner is derived. The operating principle of QRI at inverting mode is analyzed, and it is shown that the maximum voltage of resonant dc link is confined to twice the dc source voltage and that both the zero voltage switching of inverter and the zero current switching of inserted switch are guaranteed. An appropriate current control algorithm is suggested, and the opeating characteristics of proposed resonant inverter are verified through both simulation and experiment.

  • PDF

리졸버를 사용한 브러쉬 없는 직류전동기의 운전특성과 주파수 제한기를 가진 'ON-OFF'전류제어 방식 (ON-OFF' Current Control Method with Frequency Limiter and Operating Characteristics of Brushless DC Motors Using Resolver)

  • 홍성수;권봉환;윤명중
    • 대한전기학회논문지
    • /
    • 제35권9호
    • /
    • pp.396-402
    • /
    • 1986
  • Although the structure of the brushless DC motor is similar to the one of the permanent magnet synchronous motor, its operating characteristics are the same as those of the permanent magnet DC motor. This is the reason that the commutators and brushes in the permanent magnet DC motor can be replaced by the power semiconductor devices and rotor position sensors for the brushless DC motor. In this paper, a current control method is presented to make a sinusoidal current waveform for constant torque generation and the operating characteristics of the brushless DC motor using the resolver as the rotor position sensor is also presented and experimented.

  • PDF

Self-Oscillating Switching Technique for Current Source Parallel Resonant Induction Heating Systems

  • Namadmalan, Alireza;Moghani, Javad Shokrollahi
    • Journal of Power Electronics
    • /
    • 제12권6호
    • /
    • pp.851-858
    • /
    • 2012
  • This paper presents resonant inverter tuning for current source parallel resonant induction heating systems based on a new self oscillating switching technique. The phase error is suppressed in a wide range of operating frequencies in comparison with Phase Locked Loop (PLL) techniques. The proposed switching method has the capability of tuning under fast changes in the resonant frequency. According to this switching method, a multi-frequency induction heating (IH) system is proposed by using a single inverter. In comparison with multi-level inverter based IH systems, the advantages of this technique are its simple structure, better transients and wide range of operating frequencies. A laboratory prototype was built with an operating frequency of 35 kHz to 55 kHz and 300 W of output power. The performance of the IH system shows the validity of the new switching technique.

Analysis of Generalized n-winding Coupled Inductor in dc-dc Converters

  • Kang, Taewon;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.88-89
    • /
    • 2017
  • This paper investigates the design of multi-winding coupled inductor for minimum inductor current ripple in rapid traction battery charger systems. Based on the general circuit model of multi-winding coupled inductor together with the operating principles of dc-dc converter, the relationship between the ripple size of inductor current and the coupling factor is derived under the different duty ratio. The optimal coupling factor which corresponds to a minimum inductor ripple current becomes -(1/n-1), i.e. a complete inverse coupling without leakage inductance, as the steady-state duty ratio operating point approaches 1/n, 2/n, … or (n1)/n. In an opposite manner, the optimal coupling factor value of zero, i.e. zero mutual inductance, is required when the steady-state duty ratio operating point approaches either zero or one.

  • PDF

전압원 구동시의 전류형 인버어터의 특성연구 (A Study on characteristics of Current-Fed Type Inverter driven by Voltage Source)

  • 이달해;김동희;이봉섭;유동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.587-590
    • /
    • 1991
  • It is general to make the circuit analysis of current-fed type inverter driven by current source with rippleless input under the assumption of infinite induction Ld in direct current reactor(DCL). This paper focusing on the fact that Ld has bounded value in real circuit, examines operating characteristics by analysis of static state characteristics of current type inverter driven by voltage source and compares it with the operating characteristics of the circuit driven by current source.

  • PDF

SMES용 kA급 초전도도체의 운전전류 특성 (Operating Current Characteristics of a kA Class Conductor for a SMES device)

  • 류경우;최병주;김해종;성기철
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.3-6
    • /
    • 2003
  • We have developed a small-sized superconducting magnetic energy storage (SMES) device, which provides electric power with high quality to sensitive electric loads. In large magnets such as the SMES magnets the stability, which is determined by several factors, e.g. conductors cooling condition and operating current, magnets winding structure, is a crucial problem. The effect of the cooling condition, the copper ratio, and the conductor's size upon the recovery currents was investigated experimentally. The results indicate that the recovery current characteristics of the strands vary considerably according to their insulation method. In the fully insulated strands with a low copper ratio, the recovery current densities range from 10 to 20 % of their engineering critical current densities. The recovery current density of the 30-conductor with a cooling channel is about a factor of 1.8 higher than that without a cooling channel.

  • PDF

가속열화시험에 의한 18kV ZnO 피뢰기의 누설 전류 특성 분석 (Leakage Current Characteristics of 18kv ZnO Lightning Arresters by Accelerated Aging Test)

  • 김주용;송일근;김찬영;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권2호
    • /
    • pp.62-67
    • /
    • 2002
  • This paper provides the results of accelerated aging test of 18kV ZnO lightning arresters to investigate the leakage current characteristics. It was impossible to establish the replacement criterion for field operating lightning arrester because conventional aging test was only focused on the aging of ZnO elements. In general, it is possible to replace the aged arresters before the failure in the field using the leakage current measurement because it must be increased by the aging. But we can not use the method because we don't know the characteristics of the installed lightning arresters. Therefore in this paper we applied operating voltage and accelerating cycle which consists of temperature and humidity to the arresters. Then we measured the variation of total and resistive leakage current and found out the characteristics of the acted lightning arresters.

양해 추계학적 동적계획기법에 의한 저수지 운영률 개발 (Development of Reservoir Operating Rule Using Explicit Stochastic Dynamic Programming)

  • 고석구;이광만;이한구
    • 한국수자원학회논문집
    • /
    • 제30권3호
    • /
    • pp.269-278
    • /
    • 1997
  • 저수지 운영의 기초가 되는 운영률은 대부분 과거기록 유입량중 최대 혹은 최소의 극한치 자료를 이용하거나 평균치 자료를 이용하여 도출하기 때문에 실제 운영에서 발생할 수 있는 불확실성에 대처한 기대편익 산정이나 운영방안 수립에는 적절히 이용할 수 없다. 또한 지금까지 개발된 대부분의 운영률은 유입량을 포함하여 모든 운영변수를 이미 알고 있다는 확정론적 방법에 기초하고 있어 유입량의 불확실성을 반영하지 못하는 단점이 있다. 이를 개선할 수 있는 방법으로 추계학 분석기법에 의한 운영률을 개발할 수 있는데 이는 저수지 상태방정식의 구성요소인 유입량의 추계학적 특성을 시계열상에서 이산화된 천이확률로 처리하여 모형에 적용할 수 있다. 확정론적 방법에 의한 저수지 운영방안을 개선시키기 위하여 추계학적 방법에 의한 저수지 운영률을 개발하였다. 본 연구에서는 이와같은 방법론에 따른 양해 추계학적 동적계획기법을 이용하여 충주 저수지 시스템의 최적 운영 방안을 마련하였다. 개발된 운영률을 홍수기를 제외하고는 Lag-1 Markov 모형의 기본가정을 충실히 따르고 있어 저수지 운영률로의 이용이 가능하며, 운영단계의 유입량을 적절히 예측할 수 없는 현실에서 전단계의 유입량과 적용단계의 저류량만을 이용하는 저수지 운영률의 개발이 가능하다.

  • PDF