• Title/Summary/Keyword: one-way measurement

Search Result 535, Processing Time 0.032 seconds

A Survey on Knowledge of Diabetes and Self-care Behavior of Rural Patients with Diabetes Mellitus (농촌지역 당뇨병 환자의 당뇨지식 및 자가관리에 대한 연구)

  • Lee, Hye-Ran
    • Journal of Korean Academy of Rural Health Nursing
    • /
    • v.8 no.1
    • /
    • pp.13-24
    • /
    • 2013
  • Purpose: The purpose of this study was to examine the knowledge of diabetes and self-care behavior of patients with diabetes mellitus living in rural area. Methods: Participants in this study were 94 patients with type 2 diabetes mellitus. Data were collected from July 13 to September 14, 2012. The instruments were the knowledge of diabetes measurement developed by Park Oh Jang and the measurement of self-care behavior for patients with diabetes developed by Kim Young Ok. Data were analyzed using the SPSSWIN 18.0 program for t-test, one-way ANOVA and Scheffe test. Results: There were significant differences in knowledge of diabetes according to education level (p=.011), alcohol use (p=.010), regular exercise (p=.046), and duration of illness (p=.045). There were significant differences in self-care behavior of patients with diabetes according to satisfaction with income (p=.031), regular exercise (p<.001), experience with diabetes education (p=.001), number of diabetes education sessions (p<0.001), and complications (p=.001). Conclusion: Based on the result of this study, there is a need to develop and confirm the efficacy of education programs by examining their fit to characteristics of patients with diabetes mellitus living in rural areas.

Volumetric Interferometry Using Spherical Wave Interference for Three-dimensional Coordinate Metrology

  • Rhee, Hyug-Gyo;Chu, Ji-Young;Kim, Seung-Woo
    • Journal of the Optical Society of Korea
    • /
    • v.5 no.4
    • /
    • pp.140-145
    • /
    • 2001
  • We present a new method of volumetric interferometer, which is intended to measure the three-dimensional coordinates of a moving object in a simultaneous way with a single optical setup. The method is based on the principles of phase-measuring interferometry with phase shifting. Two diffraction point sources, which are made of the polished ends of single-mode optical fibers are embedded on the object. Two spherical wavefronts emanate from the diffraction point sources and interfere with each other within the measurement volume. One wavefront is phase-shifted by elongating the corresponding fiber using a PZT extender. A CCD array sensor fixed at the stationary measurement station detects the resulting interference field. The measured phases are then related to the three-dimensional location of the object with a set of non-liner equations of Euclidean distance, from which the complete set of three-dimensional spatial coordinates of the object is determined through rigorous numerical computation based upon the least square error minimization.

A study for the characteristics of milli-gloss variation of unprinted coated paper and objective measurement tools for it

  • Jeon, Sung J.;Song, Yo H.;Lee, Jae S.;Shim, Gyu S.
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.04a
    • /
    • pp.118-125
    • /
    • 2000
  • Gloss uniformity on unprinted coated papers is oftenly called as 'Surface Feeling' in market and roles as a very important criteria when a customer choose a paper. However, there is few researches on this quality so far and even there isn't much knowledge on the characteristics of gloss variation, ie what it is, where it comes from etc. Therefore, there should be a pre-research on its characteristics, factors, measuring method or tools prior to the following development activities. In this paper, we obtained about a dozen of papers including foreign products and measured not only basic properties of them, but also various characteristics related to ununiformity. Our experiments went further to printing, but that area is excluded in this paper. Also, we investigated several instruments for measuring gloss variation by an objective way all over the world and tested with our own samples so that we tried to find out which one is best-correlated with visual appreciation and suggest its results as possible. We found out several things from these experiments including what is difference between good and bad gloss uniformity, the factors of gloss variation, and the results of measurement for gloss variation with instruments.

  • PDF

A Study on Improvement of Size Table Sign for Clothing (의류 치수 조견표 개선에 관한 연구)

  • Shin, Yun-Ha;Lee, Myung-Hee
    • Fashion & Textile Research Journal
    • /
    • v.12 no.1
    • /
    • pp.109-113
    • /
    • 2010
  • Since July 2007, the government has banned the use of the existing non-legal measurement units, and has forced us to use the unified legal measurement. Therefore, the existing clothing size unit also has been changed into centimeter dimensions from inches. However, consumers have been familiar to used to the traditional inches unit. So they have the confusion to directly survey the size table sign for clothing or to contact the employee when purchasing clothing. By the current size table sign the customers can compare the inches unit and centimeters unit, but they are difficult to see it. Therefore, there is necessary to improve the size table sign by the way that can be easy to be found and seen by consumers is given to the clothing corners. In this research, three improved size table signs were developed. And they were evaluated by the consumers in terms of preferences and awareness of them. Eventually, the best size table sign was selected. From this result, if the large-discount mart use the best improved size table sign on behalf of the current one, the problems of existing size table sign will overcome and improve customer satisfaction.

The Analysis on Relation between Hamstring Length and Static Uprighting Balance (넙다리 뒤근육의 길이와 정적 기립균형과의 상관성 분석)

  • Nam, Kun-Woo
    • Journal of Korean Physical Therapy Science
    • /
    • v.18 no.1
    • /
    • pp.51-60
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate hamstring length during static uprighting position using weight distribution ratio. Methods: Ninety-six volunteers(56 males) were participated. The active knee extension test(AKE) was measured 3 times on both legs. The mean score of AKE was obtained. Then, the measurement of weight distribution ratio was observed 3 times on both legs, and its mean value was also calculated. Subjects were divided four groups based on their hamstring length measurement; both hamstring shortening group, left hamstring shortening group, right hamstring shortening group and normal hamstring length group. One-way ANOVA was employed to analyse collected data. Pearson's correlation was also hired to see any relationship between the hamstring length and the weight distribution. Results: In anterior/left area and posterior/right area, both hamstring shortening group left hamstring shortening group were superior to right hamstring shortening group and normal hamstring length group. Significant difference was existed statistically(p<.05) between groups. The correlation analysis between hamstring length and weight distribution ratio has not been shown any significant findings(Pant/post=0.733, Plt/rt=0.135). Conclusion: The results of the study may be applied to therapeutic management in posture and movement skill in musculoskeletal physical therapy.

  • PDF

Clinical Validity of Tooth Size Measurements Obtained via Digital Methods with Intraoral Scanning

  • Mohammed, Alnefaie;Sun-Hyung, Park;Jung-Yul, Cha;Sung-Hwan, Choi
    • Journal of Korean Dental Science
    • /
    • v.15 no.2
    • /
    • pp.132-140
    • /
    • 2022
  • Purpose: Dental diagnostic records derived from study models are a popular method of obtaining reliable and vital information. Conventional plaster models are the most common method, however, they are being gradually replaced by digital impressions as technology advances. Moreover, three-dimensional dental models are becoming increasingly common in dental offices, and various methods are available for obtaining them. This study aimed to evaluate the accuracy of the measurement of dental digital models by comparing them with conventional plaster and to determine their clinical validity. Materials and Methods: The study was conducted on 16 patients' maxillary and mandibular dental models. Tooth size (TS), intercanine width (ICW), intermolar width (IMW), and Bolton analysis were taken by using a digital caliper on a plaster model obtained from each patient, while intraoral scans were manually measured using two digital analysis software. A one-way analysis of variance test was used to compare the dental measurements of the three methods. Result: No significant differences were reported between the TS, the ICW and IMW, and the Bolton analysis through the conventional and two digital groups. Conclusion: Measurements of TS, arch width, and Bolton analysis produced from digital models have shown acceptable clinical validity. No significant differences were observed between the three dental measurement techniques.

Effect of 1-RM Direct Measurement Method on Beginners' Back Squat (1-RM 직접측정법이 초보자의 백스쿼트에 미치는 영향 )

  • Jaeho, Kim;Sukhoon, Yoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.32 no.4
    • /
    • pp.134-140
    • /
    • 2022
  • Objective: This study aims to verify effect of 1-RM direct measurement method of back squat on beginners. Method: Total of 8 healthy adults were recruited for this study (age: 29 ± 3.81 yrs., height: 174 ± 3.83 cm., body mass: 74 ± 11.63 kg., 1RM: 96 ± 19.78 kg). All participants performed the back squat with 80%, 90% and 100% of the pre-measured 1RM. A three-dimensional motion analysis was performed with 8 infrared cameras and 3 channels of EMG were used for this study. One-way ANOVA with repeated measure was used for the statistical analysis with the significant level set to α=.05. Results: The ankle joint ROM in the transverse plane was significantly increased as the weight increased during the concentric contraction phase 2 (p < .05). In addition, the erector spinae and the gluteus maximus, which are synergist for the motion, showed a significant difference according to the increased weight (p < .05). Conclusion: Our results revealed that beginners increase potential dynamic knee valgus as weight increased. Therefore, it is thought that field coaches should pay attention to this to minimize and prevent injuries when measuring 1-RM for beginners.

Classification of Fall Direction Before Impact Using Machine Learning Based on IMU Raw Signals (IMU 원신호 기반의 기계학습을 통한 충격전 낙상방향 분류)

  • Lee, Hyeon Bin;Lee, Chang June;Lee, Jung Keun
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.96-101
    • /
    • 2022
  • As the elderly population gradually increases, the risk of fatal fall accidents among the elderly is increasing. One way to cope with a fall accident is to determine the fall direction before impact using a wearable inertial measurement unit (IMU). In this context, a previous study proposed a method of classifying fall directions using a support vector machine with sensor velocity, acceleration, and tilt angle as input parameters. However, in this method, the IMU signals are processed through several processes, including a Kalman filter and the integration of acceleration, which involves a large amount of computation and error factors. Therefore, this paper proposes a machine learning-based method that classifies the fall direction before impact using IMU raw signals rather than processed data. In this study, we investigated the effects of the following two factors on the classification performance: (1) the usage of processed/raw signals and (2) the selection of machine learning techniques. First, as a result of comparing the processed/raw signals, the difference in sensitivities between the two methods was within 5%, indicating an equivalent level of classification performance. Second, as a result of comparing six machine learning techniques, K-nearest neighbor and naive Bayes exhibited excellent performance with a sensitivity of 86.0% and 84.1%, respectively.

The Study on Index of Greeness in Streets of Seoul by Using Automatic Measurement Techniques (자동 계측 기법을 이용한 서울 주요 가로의 녹시율 분석)

  • Nam, Chang Jin;Bang, Jae Sung;Jang, Dae Hee
    • KIEAE Journal
    • /
    • v.12 no.2
    • /
    • pp.93-101
    • /
    • 2012
  • In this study, we measured the Index of Greeness(I.O.G) and analyzed factors that affect in downtown street of Seoul. The aim of this article is to provide an ways of improving I.O.G, with an emphasis on accuracy of measurement. We utilized the autimatic measurment techniques proposed by Tonosaki to solve the problem of accuracy in measurement. The result is as follows : Firstly, the average I.O.G of Gwanghwamun Plaza is 15.76%, Jongno is 11.48% and Dasanro(from Yaksu station to Beotigogae station) is 6.36%. According to the comprehensive analysis in three reseach areas, it shows that I.O.G is intimately linked with planting method, species of trees and the presence of wall planting. Secondly, it was analyzed that grass and ground-cover planting promote I.O.G better than other method. The I.O.G of photo which contains grass is 45.47%. According to the comparative analysis between tree planting and multi-planting method, the presence of lower planting showed a difference about 8.77% of I.O.G.. From the persipective of I.O.G, tree planting with two lines is more effective than one. The difference of two ways is about 3.24%. Thirdly, it is an efficint way to use the wall planting or vertical planting in order to promote I.O.G.. In Dasanro, The I.O.G of photo which contains wall planting or vertical planting is 45.47% in contrast to the average of I.O.G. is 6.36%. Fourthly, the difference of I.O.G between broadleaf tree and needleleaf tree was larger than we thought. If look closely confined to this study, the I.O.G of street planted by Pine is 3.61% and Eastern Sycamore Family Bottonwood is 12.55%.

Difference between shrinkage rate of irradiation amount of 3D printing UV curable resin and shrinkage rate according to a constant temperature water bath (3D 프린팅용 UV 경화 수지의 조사량 및 항온수조 침적에 따른 수축률의 차이)

  • Kim, Dong-Yeon
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.113-120
    • /
    • 2020
  • Purpose: This study is to compare and analyze the shrinkage of the specimen after UV irradiation of UV cured resin at 5, 15, and 30 minutes. Methods: A cylindrical UV cured specimen was produced using a stainless steel mold. UV cured resin specimens were prepared in three groups: 5 minutes cured (5M), 15 minutes cured (15M), and 30 minutes cured (30M). The measurement was made in total 3rd. The measurement was made in total 3rd. The primary measurement was made after 24 hours using a digital measuring instrument. The 2nd and 3rd measurements were deposited in a constant temperature water bath and the shrinkage was measured. The measured data was calculated by referring to the ASTM C326 linear measurement calculation method. T-test and One-way ANOVA were performed to test the significance between groups. The post-test was conducted with Tukey (α=0.05). Results: When the inner diameter and the outer diameter of the three groups not placed in the water bath were compared and analyzed, the contraction was the smallest at 6.8% in the 5M group, and the contraction was the largest at 7.3% in the 30M group. In the outer diameter, the contraction of the 5M group was the smallest at 3.5%, and the contraction of the 30M group was the largest at 4.5%. Shrinkage decreased in all three groups immersed in a water bath for 3-7 days. Conclusion: In the UV cured resin specimen, the shrinkage increased as the amount of UV irradiation increased.