• Title/Summary/Keyword: one round

Search Result 998, Processing Time 0.034 seconds

Immunogold studies on the gonadotropes in adenohypophysis of the Korean native goat (Immunogold법에 의한 한국재래산양 샘뇌하수체의 성샘자극세포에 관한 연구)

  • Lee, In-se;Lee, Heungshik S.;Song, Seung-hoon;Yoon, Sung-tae;Hwang, In-koo;Seo, Je-hoon;Kang, Tae-cheon;Won, Moo-ho
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.5
    • /
    • pp.921-929
    • /
    • 1999
  • There have been a number of studies of gonadotropes secreting LH and FSH in the adenohypophysis, but the pattern of hormone storage and secretion of these cells still remains a controversial matter. In this study, we examined whether gonadotropes contained both of LH and FSH, and if so, how these hormones were distributed within the secretory granules. Hypophyseal sections of Korean native goat were simultaneously immunostained for LH and FSH antisera by protein A-gold technique. It was found that most gonadotropes contained both FSH and LH, but hormone storages in the secretory granules were some different among cells. Three types of gonadotropes were identified by the shape and size of the secretory granules and their hormone storage patterns. One type(I) of gonadotropes contained oval secretory granules, which immunoreactivity for FSH and LH were very weak. The size of secretory granules ranged from 160 to 310nm in diameter. Most granules contained both FSH and LH, but some contained only one of them. In another type(II) of gonadotropes, the immunreactivity and hormone storage patterns of the secretory granules were similar to those of type I cells. However, the secretory granules were round in shape and larger in size than those of type I. The other gonadotropes(type III) were distinctly distinguished by plenty of hormones in their secretory granules which were densely packed with numerous immunolabelled gold particles. These data are some inconsistent with other results that have been obtained in other ruminants like as cattle and sheep.

  • PDF

The analysis of variational characteristics on water quality and phytoplankton by principal component analysis(PCA) in Kogum-sudo, Southwestern part of Korea (주성분분석에 의한 거금수도의 수질환경 및 식물플랑크톤 변동 요인 해석)

  • 윤양호;박종식
    • Journal of Environmental Science International
    • /
    • v.9 no.1
    • /
    • pp.1-11
    • /
    • 2000
  • A study on the variational characteristics of water quality and phytoplankton biomass by principal component analysis(PCA) was carried out in Kogum-sudo from February to October in 1993. We analyzed PCA on biological factors such as chlorophyll a and phytoplankton cell numbers for centric and pennate diatoms, phytoflagellates, and total phytoplankton as well as physico-chemical factors as water temperature, salinity, transparency, dissolved oxygen(DO), saturation of DO, apparent oxygen utilization (AOU), chemical oxygen demand(COD), nutrient (ammonia, nitrite, nitrate, phosphate and silicate), N/P ratio and suspended solid(SS). The source of nutrients supply depended on the mineralization of organic matters and inputs of seawater from outside rather than runoff of freshwater. The phytoplankton biomass was changed within short interval period by nutrients change. And it was controlled by the combination of several environmental factors, especially of light intensity, ammonia and phosphate. The marine environmental characteristics were determined by the mineralization of organic matters in winter, by runoff of freshwater including high nutrients concentration in spring, by ammonia uptake and high phytoplankton productivity in summer, and phosphate supplied input seawater from outside of Kogeum-sudo in autumn. And Kogum-sudo was separated with 2 regions by score distributions of PCA. That is to say, one region was middle parts of straits which was characterized by the mixing seawater and the accumulated organic matters, other one region was Pungnam Bay and the water around Kogum Island which was done by high phytoplankyon biomass and productivity year-round.

  • PDF

Implant-supported overdentures with different bar designs: A retrospective evaluation after 5-19 years of clinical function

  • Rinke, Sven;Rasing, Hajo;Gersdorff, Nikolaus;Buergers, Ralf;Roediger, Matthias
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.338-342
    • /
    • 2015
  • PURPOSE. This retrospective study evaluated the outcome of implant-retained overdentures (IODs) after 5-19 years of clinical function. MATERIALS AND METHODS. A retrospective analysis of patient files was performed referring to 27 patients who received 36 IODs with 3 different bar designs (group A=prefabricated round bars, n=7; group B=one-piece anterior milled bars, n=20; and group C=two bilaterally placed milled bars, n=9) in the mandible (n=24) and/or in the maxilla (n=12). The analysis focused on the survival and success rates (according to Kaplan-Meier) of the implants and prostheses. Technical complication rates for each type of restoration were analyzed and compared via one-way ANOVA and the Chi-squared test. The prevalence of peri-implantitis (radiographic bone loss ${\geq}3.5mm$) was evaluated by digital analysis of panoramic radiographs taken postoperative (baseline) and after 5-19 years of clinical function (follow-up). RESULTS. The mean observational time was 7.3 years. The survival rates of the prostheses and implants were 100% and 97.7%, respectively. Technical complications occurred more frequently in group A (mean: 3.5 during observational time) than in the other two groups (B: 0.8; C: 1.0). However, this difference was not statistically significant (P=0.58). Peri-implantitis was diagnosed for 12.4% of the implants in 37% of the patients. CONCLUSION. Bar-retained IODs are an adequate treatment option for edentulous jaws. These restorations may exhibit high implant/prosthesis survival rates (>97%), and a limited incidence of technical complications after a mean observational period of >7 years. Nevertheless, peri-implantitis was identified as a frequent and serious biological complication for this type of reconstruction.

Characterization of Campylobacters Newly Isolated from Swine Gastric Mucosa

  • Lee, Yeon-Hee;Lee, Jin-Hui;Cho, Hyun-Joo;Shin, En-Joo;Park, Jong-Hwan;Park, Jae-Hak
    • Journal of Microbiology and Biotechnology
    • /
    • v.9 no.6
    • /
    • pp.778-783
    • /
    • 1999
  • Campylobacter is a pathogen for both humans and animals that can be transferred from animals to humans. Four isolates, which grew under 5-10% $CO_2$ and had small and translucent colonies, were obtained from swine gastric mucosa and characterized using various methods. These bacteria were gram negative, spirally shaped with round ends. One or two non-sheathed polar flagella were observed under electron microscopy. A PCR with species-specific protein (SSP) primers for 16S rRNA gene in Campylobacter produced a typical 462 bp fragment. The isolates had various biochemical and molecular characteristics which differentiated them from other Campylobacters. The isolates were catalase and oxidase positive, urease (rapid) negative, nitrate reduction positive, indoxyl acetate hydrolysis positive, y-glutamyl transpeptidase negative, and alkaline phosphatase negative. All four isolates showed growth at $37^{\circ}C{\;}and{\;}42^{\circ}C{\;}but{\;}not{\;}at{\;}25^{\circ}C$, were resistant to cephalotin and cefoperazone, and susceptible to carbenicillin. The isolates showed various results in the reduction of chloride to triphenyl tetrazolium (TTC) and a susceptibility to nalidixic acid. Western blot analysis of these isolates with antiserum raised against one isolate showed different patterns from those of reference strains. A dendrogram drawn with the RAPD results showed that these isolates belonged to a new Campylobacter spp. group different from those of C. jejuni, C. doylei, C. lari, and C. coli.

  • PDF

Encryption/Decryption the same improved RC6 algorithm (암호/복호를 동일하게 개선한 RC6 알고리즘)

  • Kim, Gil-Ho;Kim, Jong-Nam;Cho, Gyeong-Yeon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.247-250
    • /
    • 2008
  • RC6 which has different algorithm of encryption and decryption has been implemented to have the same algorithm between encryption' and decryption though inserting symmetry layer using simple rotate and logical operation. That means the half of whole RC6 round uses encryption algorithm and the rest of it uses decryption one and symmetry layer has been put into the middle of encryption and decryption. The proposed RC6 algorithm has no difference with the original one in the speed of process. However it is quite safe because by inserting symmetry layer the path of high probability which is needed for differential and linear analysis is cut oft so that it is hard to be analyzed. The proposed algorithm can be easily applied to the algorithm which has different encryption and decryption an make it same, and it can be good idea to be used to design a new block cipher algorithm.

  • PDF

Analytical Modelling and Heuristic Algorithm for Object Transfer Latency in the Internet of Things (사물인터넷에서 객체전송지연을 계산하기 위한 수리적 모델링 및 휴리스틱 알고리즘의 개발)

  • Lee, Yong-Jin
    • Journal of Internet of Things and Convergence
    • /
    • v.6 no.3
    • /
    • pp.1-6
    • /
    • 2020
  • This paper aims to integrate the previous models about mean object transfer latency in one framework and analyze the result through the computational experience. The analytical object transfer latency model assumes the multiple packet losses and the Internet of Things(IoT) environment including multi-hop wireless network, where fast re-transmission is not possible due to small window. The model also considers the initial congestion window size and the multiple packet loss in one congestion window. Performance evaluation shows that the lower and upper bounds of the mean object transfer latency are almost the same when both transfer object size and packet loss rate are small. However, as packet loss rate increases, the size of the initial congestion window and the round-trip time affect the upper and lower bounds of the mean object transfer latency.

The Alar Extension Graft for Retracted Ala (Alar Extension Graft를 이용한 콧방울뒤당김의 교정)

  • Kim, Hyun soo;Roh, Si Gyun
    • Archives of Plastic Surgery
    • /
    • v.36 no.1
    • /
    • pp.66-74
    • /
    • 2009
  • Purpose: The importance of the deformities in alar - columellar complex has been underestimated in Asian ethnic groups for the last decades. Fortunately, with increasing familiarity of the open rhinoplasty techniques, the anatomic details of the nasal tip have been pointed up. Definitely, having an interest and demand for improving the sub - normal relationship between the alar rim and columella are indebted for such growing of knowledge about nasal tip anatomy. However, it is true that any single procedure is not settled as versatile and fully confident modality to correct the retracted notching of the alar rim. With this article, I should like to propose another useful option for treating retracted ala. Methods: The author has tried to correct alar rim retraction by means of: (1) Triangular onlay septal cartilage graft on the lower lateral cartilage with the medial end fixed to the anterior surface of the lateral crus(Alar extension graft), (2) Inserting lateral end of the alar extension graft to the vestibular skin pocket in the form of a finger - in - groove, (3) using the vestibular skin in the form of an advancement flap, and (4) using the soft shield graft to prevent possible visible step - off of the alar margin. Results: The author applied an alar extension graft to 16 patients in order to correct a retracted ala for the last 27 months (August, 2003 - October, 2005). The distances from alar rim to long axis of nostril were improved to be within 2 mm in all of the cases, and also the shape of the alar rim changed to a round form. Nostril asymmetry (6%) in one case, temporary palpable step - off (18%) in three cases, temporary visible step - off (6%) in one case, and temporary paresthesia of the tip (25%) in four cases were observed. Conclusion: The alar extension graft is simple and efficacious. It does not need donor sites other than the operative field, and its results are predictable. In particular, since it may give structural intensity to a weak lower lateral cartilage, it may be preferentially used for the correction of a retracted ala that arises from hypoplastic lower lateral cartilage. Moreover intensified lower lateral cartilage also improves the esthetic shape of lobule.

Primary Malignant Fibrous Histiocytoma of the Diaphragm -One Case Report- (횡격막의 원발성 악성 섬유성 조직구종 -1례 보고-)

  • 김대현;김범식;조규석;박주철
    • Journal of Chest Surgery
    • /
    • v.36 no.2
    • /
    • pp.118-121
    • /
    • 2003
  • A 25-year-old female patient was adimitted due to discomfort in the right chest and left epigastric area. Chest X-ray and chest CT showed a round 4$\times$4$\times$4cm sized mass located in the right lower lobe and abutted on the right diaphragm and metastatic lesions in the right lower lobe and right middle lobe. In exploratory thoracotomy, we discovered a mass originating from the right diaphragm which directly invaded the right lower lobe and metastatic subpleural lesions in the right lower lobe and right middle lobe. The mass was diagnosed as sarcoma by frozen section biopsy and we removed the mass by on bloc resection of the right diaphragm and right lower lobe. Metastatic subpleural lesions in the right lower lobe and right middle lobe were removed by wedge resection. The mass was malignant fibrous histiocytoma of the diaphragm in permanent pathologic examination and chemotherapy was done as adjuvant measure. We report one extremely rare case of malignant fibrous histiocytoma of the diaphragm with literature.

Effect of Shoulder Abduction Angles on EMG Activity of the Abdominal Muscles during Single Leg Holding on the Foam Roller

  • Yun, Sung joon;Kim, Jun hee
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.4
    • /
    • pp.228-232
    • /
    • 2020
  • Purpose: This study examined the electromyography (EMG) activity of the abdominal muscles and the ratio of the oblique abdominal muscle activity to the rectus abdominis muscle during a single-leg holding position with isometric shoulder abduction (SLHISA) in the supine position on a foam roller. Methods: Nineteen healthy males were recruited to the study. Each subject was asked to lay on a round foam roller and perform singleleg (nondominant) holding with contralateral shoulder abduction to one of three angles (45°, 90°, or 135°) in random order. The surface EMG signals of the bilateral rectus abdominis (RA), external oblique abdominis (EO), and combined internal oblique abdominis (IO) and transverse abdominis (TrA) muscle were collected during the tasks. The EO/RA and (IO & TrA)/RA ratios were determined using surface EMG. One way repeated measure ANOVA with three SLHISAs was used to assess the significant abdominal muscle EMG activity and the ratio of the oblique abdominal muscles activity to the RA muscle. The statistical significance level was p<0.05. Results: The results were as follows. The SLHISA 135° showed significantly higher EMG activity of both RAs, left EO, and right IO & TrA muscles (p<0.05). The right EO and left IO and TrA muscles/RA were significantly different among the SLHISA angles. The SLHISA 45° showed a significantly greater ratio of right EO/RA and left IO & TrA/RA (p<0.05). Conclusion: SLHISA on a foam roller is useful for lumbopelvic stabilization exercise by increasing the activity and recruiting a specific pattern of the oblique abdominal muscle.

EFFECT OF SALIVARY CONTAMINATION OF TEETH ON MICROTENSILE BOND STRENGTH OF VAR10US DENTIN BONDING SYSTEMS. (타액에 의한 오염이 상아질 접착제의 미세전단결합강도에 미치는 영향)

  • Choi, Kyoung-Kyu;Ryu, Gil-Joo
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.3
    • /
    • pp.203-208
    • /
    • 2003
  • The purpose of this study was to evaluate the effect of salivary contamination of teeth on bonding efficacy of self-priming and self-etching DBSs. The materials used were Single Bond(SB, self-priming system, 3M), Unifil Bond(UB, self-etching system, GC), and Scotchbond Multi-Purpose Plus(SM, 3M) as control. Forty five human molars randomly allocated to three groups as dentin bonding systems tested and embedded in epoxy resin. Then the specimens were wet-ground to expose flat buccal enamel surface or flat occlusal dentin surface and cut bucco-lingually to form two halves with slow speed diamond saw. One of them was used under non-contamination, other under contamination with saliva. The bonding procedure was according to the manufacturer's directions and resin composite(Z-100, 3M Dental Products, St. Paul, MN) was built-up on the bonded surface 5mm high. The specimens were ground carefully at the enamel-composite interface with fine finishing round diamond bur to create an hour-glass shape yielding bonded surface areas of $1.5{\pm}0.1\textrm{mm}^2$. The specimens were bonded to the modified microtensile testing apparatus with cyanoacrylate, attached to the universal testing machine and stressed in tension at a CHS of 1mm/min. The tensile force at failure was recorded and converted to a tensile stress(MPa). Mean values and standard deviations of the bond strength are listed in table. One-way ANOVA was used to determine significant difference at the 95% level. The bond strength of SBMP and SB were not affected by salivary contamination, but that of UB was significantly affected by salivary contamination. These results indicate that DBSs with total etch technique seems less likely affected by salivary contamination in bonding procedure.