• Title/Summary/Keyword: nuclear disaster

Search Result 169, Processing Time 0.022 seconds

A Study on Analysis of Requirements in the Smart Societal Security Wireless Network (스마트 사회안전무선통신망 요구사항 분석에 관한 연구)

  • Choi, Jae-Myeong;Woo, Byung-Hoon;Kang, Heau-Jo
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.5
    • /
    • pp.518-523
    • /
    • 2014
  • The development of Societal and Scientific technologies have increased risk of dysfunction caused by new technologies such as nuclear power, information technology. Also, urbanization and population density is increasing risk to high-rise building fires, traffic accidents, crime and etc. Implementation of wireless communication network on the societal security is very necessary for prevention, preparation and response against these risks. It always consists maintenance, management and the network must be maintained in an emergency. In this paper, we studied the societal security wireless communication network for prevention, preparation and response against complex disasters, and analyzed requirements(essential function, add-ons) for implementation network in the societal security wireless network.

A Study on the Effective Fire and Smoke Control in Road-Tunnel with Semi-Transverse Ventilation (도로터널 화재시 반횡류식 균일배기 환기방식에서의 최적배연 연구)

  • Jeon, Yong-Han;Yoo, Ji-Oh;Kim, Nam-Jin;Seo, Tae-Boem;Kim, Jong-Yoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.3
    • /
    • pp.186-192
    • /
    • 2009
  • In this study it is intended to review the moving characteristics of smoke by performing visualization for calculation of the optimal smoke exhaust air volume in case a fire occurs in tunnels where transverse ventilation is applied, and to obtain basic data necessary for design of the smoke exhaust systems by deriving optimal smoke exhaust operational conditions under various conditions. As a result of this study, if it was assumed 0 critical velocity in the tunnel, the smoke exhaust air volume was limited within 250 meter in the road-tunnel disaster prevention indicator and the exhaust efficiency was from 55.1% to 95.8% in the result of this study. In case of oversized exhaust ports, the generated smoke is more than the case of uniform exhaust. When the critical velocity in the tunnel is 1.75 m/s and 2.5 m/s, the optimal smoke exhaust air volume has to be more than $173\;m^3/s$, $236\;m^3/s$ for the distance of the moving smoke which can limit the distance to 250 m.

A Survey on Safety Analysis Techniques for Safety-Critical Systems (안전 필수 시스템을 위한 안전성 분석 기법)

  • Kim, Eui-Sub;Yoon, Sanghyun;Yoo, Junbeom
    • Journal of Convergence Society for SMB
    • /
    • v.2 no.1
    • /
    • pp.11-18
    • /
    • 2012
  • As scale of software has been expanded and complicated, it is difficult to detect hazards which induce functional failure of software. Functional failure of safety-critical system (nuclear power plant, air traffic control systems, railway operating system) could result in a disaster (personal injury, environmental pollution). Therefore, it is necessary to conduct a safety analysis for preventing functional failure and increasing safety of the software. However, there are some reasons (time and effort problem, low knowledge of various safety analysis techniques, selecting conventional technique in company, organization) which disturb selecting an apposite one. This paper presents some traditional safety analysis techniques, recently presented techniques and combined models. We expect that it helps stakeholders to choice adequate one for target system.

  • PDF

Strategy for Advancement of Current Pre-hospital Emergency Medical Service (현 병원 전 단계 응급의료서비스의 선진화 전략)

  • Shin, Seong-Yoon;Chai, Seung-Ki;Jang, Dai-Hyunl;Park, Sang-Joon;Choi, Byeong-Seok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.12
    • /
    • pp.265-271
    • /
    • 2011
  • High-quality customized services demand was growing due to the increase of aging, extremely nuclear family, disaster vulnerable of society. Ambulance service is required of fast and professional rescue and emergency service because of preventable death rate such as acute diseases, cerebral and cardiovascular diseases, suicides, etc. was higher than in developed countries. First aid will be available using patients information when emergency occurs, before arriving at the hospital. And emergency department is equipped with that patient care can be prepared in advance, increase the efficiency of emergency care. We received a variety of complex emergency call using high social awareness of 119 number and propose an efficient emergency medical service advancement strategy building an integrated response system with relevant organization.

Analysis on the Factors Influencing Risk Perception and Risk Taking Behavior to Japanese Fishery Products: Focused on Affect Factor (일본산 수입 수산물에 대한 위험인식, 섭취 행동에 영향을 미치는 요인 분석: 감정요인을 중심으로)

  • Joo, Jungmin;You, Myoung-Soon
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.3
    • /
    • pp.167-175
    • /
    • 2016
  • After Fukushima Daiichi nuclear disaster, Korean government banned to import of Japanese fishery products that comes from north region of Japan. As 'fishery product trade dispute' between Korea and Japan is still in progress, consumers have been threatened their food safety. This study is to examine the factors influencing consumer's risk perception to Japanese fishery products and risk taking behavior. Survey was conducted with 1,500 adult during sep-oct 2012. The result can represent the role of affect with risk perception of Japanese fishery product. People who have negative affect to Japanese fishery products have higher risk perception. Also negative affection can influence to risk taking behavior. However the degree of fatalism is not significant factor to risk taking behavior.

A Study on the Problem of Pressure and Flow Rate by Prescriptive Code Based Design of Fire Sprinkler System (사양위주 스프링클러설비 설계의 압력과 유량의 문제점에 대한 고찰)

  • Jeong, Keesin;Kim, Wee-Kyong
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.14-19
    • /
    • 2013
  • National Fire Safety Code 103 regulates that all operating sprinkler in design area must be discharged 1 bar or more pressure and release 80 lpm or more flow rate as minimum criteria. NFSC103 also provides that the number of operating sprinkler in design area is 10, 20, 30 according to the building classification and the total flow rate is 800, 1,600, 2,400 lpm depending on 80 lpm per sprinkler. If sprinkler system is designed as above provisions, the pressure and the flow rate accordingly become smaller than the minimum criteria about 50 % sprinklers. It results in serious consequence that the purpose of sprinkler system as initial fire reaction equipment is failure. In order to solve these problems, It is desirable that Performance-based fire protection design, hydraulic calculation, is carried out to all sprinkler system.

The SAFE Management System Model Based on Context Automatic Awareness

  • Han, Kook-Hee;Liu, Yiwen;Kwon, Young-Jik;Kang, Byeong-Do
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2007.02a
    • /
    • pp.87-96
    • /
    • 2007
  • Ubiquitous is a Latin-derived word meaning "to exist at any time and place" like water or air. In computing, the word "ubiquitous" indicates an environment in which users have access to networks without any limitation regarding computer networks or places. Important issues in building Ubiquitous Korea (U-Korea) are the social problems appearing with a rapid increase in the old age population. Nowadays, with the rise of the nuclear family, the increase in the number of elderly people living alone, and the change in the status of women, both wives and husbands are employed outside the home, and the relatives who would be responsible for supporting the elderly sometimes are on long or short business trips, and it happens that old people can't be looked after. Therefore the government developed a wireless paging system for the sick, disabled, old and weak so that when an emergency happens, by just simply dialing 119, an emergency aid center could take prompt action. However, the present wireless paging systems composing the under-layer of the emergency aid information system have some problems, such as, a lack of reliability, problems among terminals, mobile transmitters and receiving terminals, the users' refusal to admit the need for the system and poor operational skills, administrators' perfunctory management and checks, etc. On account of these problems, the system efficiency has degraded and therefore a system upgrade is necessary. In this paper, we attempt to evaluate the newly implemented SAFE119 system, a new wireless paging system seeking to correct the problems of the current system.

  • PDF

A Study on Quantitative Risk Assessment Method and Risk Reduction Measures for Rail Hazardous Material Transportation (철도위험물수송에 관한 위험도 정량화방안 및 경감대책 연구)

  • Lee, Sang Gon;Cho, Woncheol;Lee, Tae Sik
    • Journal of Korean Society of societal Security
    • /
    • v.1 no.3
    • /
    • pp.69-76
    • /
    • 2008
  • The object of this study is to develop a tool for quantifying risks related to the rail transportation of hazardous commodities and to present mitigation measures. In this study, the Quantitative Risk Assessment (QRA) is used as a risk analysis tool. Based on the previous explosion history (Iri explosion) and consideration of its high risk, Iksan-si is selected as a model city. The result, expressed as average individual risk for exposed people with various distance, indicates that the model city is considered to be safe according to the nuclear energy standard. Also, the mitigation measures are provided since Societal risk of Iksan-si is set within ALARP. Risk reduction measures include rail car design, rail transportation operation, demage spread control as well as derail prevention and alternative routes for reducing accident frequencies. Finally, it is expected to achieve high level of public safety by appling the risk reduction measures.

  • PDF

Geographical Information System for Nuclear Disaster Prevention (원자력방재를 위한 지리정보시스템)

  • Lee, Gwang-Pyo;Lee, Yun;Kim, In-Hyeon
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2007.10a
    • /
    • pp.169-175
    • /
    • 2007
  • 고리, 월성, 울진, 영광 등4개 원전부지와 하나로 연구용 원자로 부지에 대해 방사성물질의 대기 중 누출사고 발생 시 대축척 전자지도와 연계한 사고정보 파악, 예상피해분석, 방재시설 및 소개정보 활용 등을 통해 중앙정부 및 지방자치단체가 방사능 물질 피해지역관리 및 신속하고 효율적인 주민대응조치 수립을 위한 의사 결정 지원할 수 있는 방사능방재 지리정보시스템 구축이 필요하다. 본 연구에서는 고리, 월성, 울진, 영광, 대전지역의 원자력 발전소 및 연구용 원자로 반경 40km이내 지역의 행정경계, 도로, 등고, 수계, 건물 등의 일반지형지물정보와, 비상계획구역 내 마을의 상세정보, 집결지, 대피소, 교통통제소, 환경방사능감시기, TLD등의 방재시설물 위치 및 관련 상세정보, 관공서, 경찰서, 소방서, 보건소, 학교, 병원 등의 방재관련 지형지물 위치 및 관련 상세정보, 원전부지 내 인구분포, 보유 차량 분포, 농작물 재배 현황, 축산물 재배현황 등의 방재관련 사회통계정보를 포함하는 공간 및 속성 데이터베이스는 구축하였다. 이를 기반으로 방사선 피폭영향 평가시스템(FADAS)의 예상평가결과를 전자지도 상에 표출하고, 이에 근거한 예상피해를 분석하며, 소개단계 대상 마을 검색 및 바람장 분석을 활용한 소개경로 제시 등을 통해 주민보호조치 의사결정을 지원하며, 사고대응 및 소개현황 정보를 관리하는 웹 기반의 원자력방재 지리정보시스템을 확대 개발하였다. 방재시설물 및 방재관련 지형지물, 방재관련 사회통계자료의 검색기능 및 실시간 원전 바람장 정보조회, 실시간 ERMS 수집정보 조회, 수치예보 정보 조회, 온라인DB관리 등의 확대 구현을 통해 사고대응조치 및 피해분석업무를 지원하였다. 본 연구를 통한 원자력방재 지리정보시스템 완성을 통해 방사능 비상시 중앙본부와 지역본부 및 유관기관 간에 지리정보와 연계한 정확한 사고정보 및 방재정보의 신속한 공유를 제공하고, 적절한 비상대응조치 의사결정 및 주민보조조치 수행을 지원하여 효율적인 사고지역 관리 및 인적 물적 자원의 피해를 최소화하는데 기여할 것으로 기대된다.

  • PDF

The Implementation of Hardware Verification System Using Fault Injection Method (결함 주입 방법을 이용한 하드웨어 검증시스템 구현)

  • Yoon, Kyung-Shub;Song, Myoung-Gyu;Lee, Jae-Heung
    • Journal of IKEEE
    • /
    • v.15 no.4
    • /
    • pp.267-273
    • /
    • 2011
  • In hardware design, its stability and reliability are important, because a hardware error can cause serious damages or disaster. To improve stability and reliability, this paper presents the implementation of the hardware verification system using the fault injection method in PC environment. This paper presents a verification platform that can verify hardware system reliably and effectively, through a process to generate faults as well as insert input signals into the actual running system environment. The verification system is configured to connect a PC with a digital I/O card, and it can transmit or receive signals from the target system, as a verifier's intention. In addition, it can generate faults and inject them into the target system. And it can be monitored by displaying the received signals from the target system to the graphical wave signals. We can evaluate its reliability by analyzing the graphical wave signals. In this paper, the proposed verification system has been applied to the FPGA firmware of a nuclear power plant control system. As a result, we found its usefulness and reliability.