• Title/Summary/Keyword: normalized k

Search Result 2,395, Processing Time 0.037 seconds

Evaluation of Permanent Lateral Displacement of a Cyclic Laterally Loaded Pile in Sandy Soil (모래지반에서 횡방향 반복하중을 받는 말뚝의 영구수평변위 평가)

  • Baek, Sung-Ha;Kim, Joon-Young;Lee, Seung-Hwan;Chung, Choong-Ki
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.2
    • /
    • pp.17-26
    • /
    • 2017
  • Pile foundations that support offshore structures or transmission towers are dominantly subjected to cyclic lateral loads due to wind and waves, causing permanent displacement which can severely affect stability of the structures. In this study, a series of cyclic lateral load tests were conducted on a pre-installed aluminum flexible pile in sandy soil with three different relative densities (40%, 70% and 90%) in order to evaluate the permanent displacement of a cyclic laterally loaded pile. Test results showed that the cyclic lateral loads accumulated the irreversible lateral displacement, so-called permanent displacement. As the number of cyclic lateral load increased, accumulated permanent displacement increased, but the permanent displacement due to one loading cycle gradually decreased. In addition, the permanent displacement of a pile increased with decrement of relative density and decreased by soil saturation. From the test results, the normalized permanent displacement defined as the cumulative permanent displacement to the initial permanent displacement ratio was investigated, and empirical equations for predicting the normalized permanent displacement was developed in terms of relative density of the soil and the number of cyclic lateral load.

Characteristic of the Radiation Heat Flux Distribution for the KIER Solar Furnace (KIER 태양로의 열유속 분포 특성)

  • Chai, Kwan-Kyo;Lee, Hyun-Jin;Kim, Jong-Kyu;Yoon, Hwan-Ki;Lee, Sang-Nam;Kang, Yong-Heack;Seo, Tae-Beom
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.74-79
    • /
    • 2011
  • Concentration characteristics of the KIER solar furnace are analyzed with a heat flux measurement technique. Total heat capacity of 40kW was confirmed within 1.04% average error, and the normalized maximum heat flux of 3,452 $kW/m^2$ was proved. Non-Gaussian flux distribution in the vertical direction implies that reflectors should not be random rather inclined downwards. Moreover, we characterized flux distribution variations with furnace blind opening ratio, distance from the focal plane, and misalignment of the measurement system. Based on the results, the heat flux distribution can be simply estimated once reflectivity and direct normal insolation values are known. This study will be helpful to the design and the performance evaluation of receivers or chemical reactors.

  • PDF

Analysis of Propagating Crack Along Interface of Isotropic-Orthotropic Bimaterial by Photoelastic Experiment

  • Lee, K.H.;Shukla, A.;Parameswaran, V.;Chalivendra, V.;Hawong, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.102-107
    • /
    • 2001
  • Interfacial cracks between an isotropic and orthotropic material, subjected to static far field tensile loading are analyzed using the technique of photoelasticity. The fracture parameters are extracted from the full-field isochromatic data and the same are compared with that obtained using boundary collocation method. Dynamic Photoelasticity combined with high-speed digital photography is employed for capturing the isochromatics in the case of propagating interfacial cracks. The normalized stress intensity factors for static crack is greater when $\alpha=90^{\circ}C$ (fibers perpendicular to the interface) than when $\alpha=0^{\circ}C$ (fiber parallel to the interface) and those when $\alpha=90^{\circ}C$ are similar to ones of isotropic material. The dynamic stress intensity factors for interfacial propagating crack are greater when $\alpha=0^{\circ}C$ than $\alpha=90^{\circ}C$. The relationship between complex dynamic stress intensity factor $|K_D|$ and crack speed C is similar to that for isotropic homogeneous materials, the rate of increase of energy release rate G or $|K_D|$ with crack speed is not as drastic as that reported for homogeneous materials.

  • PDF

GBCK25, fermented ginseng, attenuates cardiac dysfunction in high fat diet-induced obese mice

  • Sharmila, Judith;Aravinthan, Adithan;Shin, Dong Gue;Seo, Jeong Hun;Kim, Bumseok;Kim, Nam Soo;Kang, Chang-Won;Kim, Jong-Hoon
    • Journal of Ginseng Research
    • /
    • v.42 no.3
    • /
    • pp.356-360
    • /
    • 2018
  • The fermentation of medicinal herbs facilitated by microbes is assumed to exert promising therapeutic efficacy on the absorption, bioavailability, and pharmacological effects by speeding up the making or conversion of active constituents into their metabolites. We examined the cardioprotective potential of fermented ginseng, GBCK25, against high-fat diet (HFD)-induced metabolic and functional illnesses as following the essential analysis such as electrocardiographic parameters, alterations of body and organ weights, and echocardiographic studies. The results exhibited that body weights were significantly reduced and the gain of different organ weights were partly eased by GBCK25 treatment. Echocardiography results proposed the amelioration of heart function through normalized levels of left ventricle systolic pressure, ejection fraction, and fractional shortening. These outcomes deliver straight confirmation that GBCK25 could be a potential nutraceutical source for the relief of HFD-induced obesity mediated cardiac dysfunctions.

Building a Graphite Calorimetry System for the Dosimetry of Therapeutic X-ray Beams

  • Kim, In Jung;Kim, Byoung Chul;Kim, Joong Hyun;Chung, Jae-Pil;Kim, Hyun Moon;Yi, Chul-Young
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.810-816
    • /
    • 2017
  • A graphite calorimetry system was built and tested under irradiation. The noise level of the temperature measurement system was approximately 0.08 mK (peak to peak). The temperature of the core part rose by approximately 8.6 mK at 800 MU (monitor unit) for 6-MV X-ray beams, and it increased as X-ray energy increased. The temperature rise showed less spread when it was normalized to the accumulated charge, as measured by an external monitoring chamber. The radiation energy absorbed by the core part was determined to have values of $0.798J/{\mu}C$, $0.389J/{\mu}C$, and $0.352J/{\mu}C$ at 6 MV, 10 MV, and 18 MV, respectively. These values were so consistent among repeated runs that their coefficient of variance was less than 0.15%.

A study on Characteristics analysis of time sharing type high frequency inverter consisting of half-bridge serial resonant inverter (Half-Bridge형 시분할방식 고주파 공진 인버터의 특성해석에 관한 연구)

  • Cho G. P.;Shin G. H.;Won J. S.;Kim D. H.;Ro C. G.;Sim K. Y.;Bae Y. H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.344-347
    • /
    • 2001
  • A high frequency resonant inverter consisting of three unit half-bridge serial resonant inverter used as power source of induction heating at high frequency is presented in this paper. As a output power control strategy, tine-sharing gate control method is applied. The analysis of the proposed circuit is generally described by using the normalized parameters. Also, according to the calculated characteristics value, a method of the circuit design and operating characteristics of the inverter is proposed. This paper proves the validity of theoretical analysis through the experiment. This proposed inverter show that it can be practically used in future as power source system for induction heating application, DC-DC converter etc.

  • PDF

Analysis of On-Line Partial Discharge Patterns in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 운전중 부분방전 패턴 분석)

  • Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1824-1827
    • /
    • 2003
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in two high voltage motors. Two 6.6kV motors were installed with 80pF capacitive couplers at the terminal box. The PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantifies such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). Off-line PD measurements were conducted on one 4.16kV motor. The motor was energized to 2.4kV, 3.0kV, 3.5kV and 4.16kV, respectively. The PD levels in pC were measured with a conventional digital PD detector. The comparison of positive to negative PD indicates whether the defect elements of PD are within the insulation or on the insulation surface. Discharge at conductor surface was discovered in No. 1 motor. Internal discharges were generated in phase A, B and C of No. 2 motor, Slot discharges occurred in three phases of No. 3 motor.

  • PDF

Fabrication of Multi-Fin-Gate GaN HEMTs Using Honeycomb Shaped Nano-Channel (벌집구조의 나노채널을 이용한 다중 Fin-Gate GaN 기반 HEMTs의 제조 공정)

  • Kim, Jeong Jin;Lim, Jong Won;Kang, Dong Min;Bae, Sung Bum;Cha, Ho Young;Yang, Jeon Wook;Lee, Hyeong Seok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.1
    • /
    • pp.16-20
    • /
    • 2020
  • In this study, a patterning method using self-aligned nanostructures was introduced to fabricate GaN-based fin-gate HEMTs with normally-off operation, as opposed to high-cost, low-productivity e-beam lithography. The honeycomb-shaped fin-gate channel width is approximately 40~50 nm, which is manufactured with a fine width using a proposed method to obtain sufficient fringing field effect. As a result, the threshold voltage of the fabricated device is 0.6 V, and the maximum normalized drain current and transconductance of Gm are 136.4 mA/mm and 99.4 mS/mm, respectively. The fabricated devices exhibit a smaller sub-threshold swing and higher Gm peak compared to conventional planar devices, due to the fin structure of the honeycomb channel.

The effect of Electromyographic activity of knee extensor during contralateral hip isometric adduction (반대측 고관절의 등척성 내전운동이 대퇴사두근의 등척성수축 근전도 활성도에 미치는 영향)

  • Lee Yun-seob;Sim Young-heon;Lim Chang-hun;Kim Myung-cheol;Sin Hyung-soo;Park Eun-se;Kim Jin-sang
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.2
    • /
    • pp.38-45
    • /
    • 2005
  • This study was deigned to identify the effect of electromyographic activity of knee extensor during contralateral hip isometric adduction. six young adults who had not experienced any knee injuries were recruited. Their Q-angles were within a normal rage. They were asked to sit on the table. The EMG activities of the vastus lateralis (VL), vastus medialis oblique (VMO) were recorded in sitting by surface electrodes and normalized by MVC EMG values derived from manual muscle test. The EMG activity levels of the VL, RF, and VMO were the highest when foot was externally rotated. The EMG activity level of VMO/VL ratio did show significant differences(p<.05). The onset time of vastus lateralis (VL) and vastus medialis oblique (VMO) was similar in contralateral hip isometric adduction(p<.05).

  • PDF

Sloshing design load prediction of a membrane type LNG cargo containment system with two-row tank arrangement in offshore applications

  • Ryu, Min Cheol;Jung, Jun Hyung;Kim, Yong Soo;Kim, Yooil
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.6
    • /
    • pp.537-553
    • /
    • 2016
  • This paper addresses the safety of two-row tank design by performing the extensive sloshing model tests. Owing to the uncertainties entangled with the scale law transforming the measured impact pressure up to the full scale one, so called comparative approach was taken to derive the design sloshing load. The target design vessel was chosen as 230 K LNG-FPSO with tow-row tank arrangement and the reference vessel as 138 K conventional LNG carrier, which has past track record without any significant failure due to sloshing loads. Starting with the site-specific metocean data, ship motion analysis was carried out with 3D diffraction-radiation program, then the obtained ship motion data was used as 6DOF tank excitation for subsequent sloshing model test and analysis. The statistical analysis was carried out with obtained peak data and the long-term sloshing load was determined out of it. It was concluded that the normalized sloshing impact pressure on 230 K LNG-FPSO with two-row tank arrangement is higher than that of convectional LNG carrier, hence requires the use of reinforced cargo containment system for the sake of failure-free operation without filling limitation.