• Title/Summary/Keyword: monolithic zirconia restoration

Search Result 33, Processing Time 0.02 seconds

Achieving Esthetics in Anterior Region using Monolithic Zirconia Restoration (Monolithic Zirconia Crown을 이용한 심미적 접근)

  • Kim, Chonghwa
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.4-14
    • /
    • 2016
  • Although CAD/CAM technology has been used in dentistry for more than decades, the present CAD/CAM dentistry is still quite inefficient or unesthetic. Zirconia restoration has faced with two contradictory words, 'Efficiency' and 'Esthetics'. One can consider monolithic zirconia restoration to be efficient with CAD/CAM. The monolithic zirconia restoration, however, is rarely esthetic due to the current limitations with zirconia. On the contrary, porcelain build-up is almost indispensible in fabricating esthetic restoration, especially in anterior region. In this article, the current status of monolithic zirconia restoration and clinical cases will be presented.

Esthetic anterior restoration using 3M LavaTM Esthetic monolithic zirconia (3M LavaTM Esthetic monolithic zirconia를 이용한 전치부 심미 수복 증례)

  • Kim, Hyung Joon;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.306-316
    • /
    • 2018
  • Monolithic zirconia has been widely used in fixed partial dentures due to high strength and fracture toughness. Nevertheless, the usage of monolithic zirconia in anterior restoration was limited because of opacity. Recently, esthetic monolithic zirconia blocks are developed by improving translucency and using various shading systems. Manufacturer introduces 3M $Lava^{TM}$ Esthetic with increased cubic phase and fluorescent ingredients is more esthetic than previous monolithic zirconia. This case report describes favorable anterior restorations using translucent monolithic zirconia.

Digital workflow of single visit full contour monolithic zirconia restoration with CEREC Omnicam intraoral scanner and fast zirconia sintering process (구강스캐너와 급속 지르코니아 소결을 이용한 당일 풀지르코니아 보철수복)

  • Lee, Soo Young
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.25 no.2
    • /
    • pp.79-87
    • /
    • 2016
  • Single visit monolithic restoration can be proceed with digital workflow which consist of intraoral scanning, dental CAD(computer aided design) and restoration milling with CAM(Computer aided manufacturing). While zirconia has more than 900MPa of flexural strength compared with 400MPa for lithium disilicate, shortened fabricating time of lithium disilicate is considered to be a better choice for fabricating single visit full contour monolithic restoration. However, new zirconia materials which are TZI C(Dentsply Sirona) and LUXEN Enamel(Dental Max), new induction heating method of sintering furnace, and new sintering protocols for MoSi2 heating elements sintering furnace offer significantly reduction of full contour monolithic zirconia restoration fabrication time with greater translucency. These new developments lead single visit zirconia restoration in reality.

Evaluation of reliability of zirconia materials to be used in implant-retained restoration on the atrophic bone of the posterior maxilla: A finite element study

  • Degirmenci, Kubra;Kocak-Buyukdere, Ayse;Ekici, Bulent
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.2
    • /
    • pp.112-119
    • /
    • 2019
  • PURPOSE. Zirconia materials have been used for implant-retained restorations, but the stress distribution of zirconia is not entirely clear. The aim of this study is to evaluate the stress distribution and risky areas caused by the different design of zirconia restorations on the atrophic bone of the posterior maxilla. MATERIALS AND METHODS. An edentulous D4-type bone model was prepared from radiography of an atrophic posterior maxilla. Monolithic zirconia and zirconia-fused porcelain implant-retained restorations were designed as splinted or non-splinted. 300-N occlusal forces were applied obliquely. Stress analyses were performed using a 3D FEA program. RESULTS. According to stress analysis, the bone between the 1) molar implant and the 2) premolar in the non-splinted monolithic zirconia restoration model was stated as the riskiest area. Similarly, the maximum von Mises stress value was detected on the bone of the non-splinted monolithic zirconia models. CONCLUSION. Splinting of implant-retained restorations can be more critical for monolithic zirconia than zirconia fused to porcelain for the longevity of the bone.

Metal stain on monolithic zirconia restoration: A case report

  • Cha, Min-Sang;Lee, Sang-Woon;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.2
    • /
    • pp.138-142
    • /
    • 2017
  • In restorative treatment using fixed dental prostheses, dentists should select appropriate restoration material among various types of dental materials. The strength, marginal fit, esthetics, wear resistance, biocompatibility, and cost are important factors in the choice of restoration materials. The present case showed a surface stain on a monolithic zirconia restoration that was due to wear between the monolithic zirconia restoration and the base metal alloy restoration. This phenomenon was confirmed by surface roughness measurement and electron probe micro-analysis.

Full mouth rehabilitation using monolithic zirconia: a clinical report (Monolithic zirconia를 이용한 전악 보철 수복: a clinical report)

  • Oh, Won-Seok;Ryu, Jae-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.358-363
    • /
    • 2015
  • Previously, the usage of monolithic zirconia in anterior restoration was limited because of problems such as the monotony of tones and shades which would compromise the outcome of esthetic purpose. Zirconia was merely used as a coping with additional porcelain veneering whereas porcelain chipping cannot be evaded. Recently, with the improvement of monolithic zirconia, the various translucency and tones made it possible to use zirconia for anterior restoration. In this case, a male patient of 63 years old received a full mouth rehabilitation with monolithic zirconia. After a period of time usage, the outcome showed a favorable result functionally and esthetically.

Esthetic Full Zirconia Fixed Detachable Implant-Retained Restorations Manufactured from Monolithic Zirconia : Clinical Report (Monolithic zirconia framework으로 제작된 fixed detachable prostheses를 이용한 심미적인 임플란트 전악 수복 증례)

  • Hong, Jun-Tae;Choi, Yu-Sung;Han, Se-Jin;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.253-268
    • /
    • 2012
  • Full-mouth reconstruction of a patient using dental implants is a challenge if there is vertical and horizontal bone resorption, since this includes the gingival area and restricts the position of the implants. however, hard- and soft-tissue grafting may allow the implants to be placed into the desired position. Although it is possible to regenerate lost tissues, an alternative is to use fixed detachable prostheses that restore the function and the esthetics of the gingiva and teeth. Various material combinations including metal/acrylic, metal/ceramic, and zirconia/ceramic have been used for constructing this type of restoration. Other problems include wear, separation or fracture of the resin teeth from the metal/acrylic prosthesis, chipping or fracture of porcelain from the metal/ceramic or zirconia/ceramic prosthesis, and fracture of the framework in some free-end prostheses. With virtually unbreakable, chip-proof, life-like nature, monolithic zirconia frameworks can prospectively replace other framework materials. This clinical report describes the restoration of a patient with complete fixed detachable maxillary and mandibular prostheses made of monolithic zirconia with dental implants. The occluding surfaces were made of monolithic zirconia, to decrease the risk of chipping or fracture. The prostheses were esthetically pleasing, and no clinical complications have been reported after two years.

Evaluation of marginal fit of monolithic zirconia restoration by digital impression (디지털 방식을 이용하여 제작한 전부 지르코니아 수복물의 변연 적합도 평가)

  • Yun, Mi-Jung;Kim, So-Yeun;Kang, Eun-Sook
    • The Journal of the Korean dental association
    • /
    • v.56 no.7
    • /
    • pp.366-374
    • /
    • 2018
  • Purpose : The purpose of this study was to compare the marginal fit of monolithic zirconia restorations fabricated form the conventional and the digital impression technique. Materials and methods : Ten patients were restored with monolithic zirconia restorations fabricated from the digital and the conventional impression technique. Before definitive insertion, silicone replicas were produced from all twenty crowns. The silicone replicas were cut in three sections; each section was evaluated at two points. The measurement was carried out by using a measuring microscope (Olympus BX 51) and I-Solution. Data from the silicone replica scores were analyzed by Shapiro-Wilk test for normal distribution and the t-test for equality of two population's mean. All tests were performed with ${\alpha}-level$ of 0.05. Results : The average marginal gaps of monolithic zirconia restorations were $133.81{\pm}36.46{\mu}m$ for the conventional impression technique, $90.07{\pm}9.47{\mu}m$ for the digital impression technique. No statistical differences were found between the two impression techniques Conclusion : Both prostheses presented clinically acceptable results with comparing the marginal fit.

  • PDF

Influence of preparation design on fracture resistance of different monolithic zirconia crowns: A comparative study

  • Findakly, Meelad Basil;Jasim, Haider Hasan
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.6
    • /
    • pp.324-330
    • /
    • 2019
  • PURPOSE. The aim of the study was to evaluate and compare the fracture resistance and modes of fracture of monolithic zirconia crowns with two preparation designs. MATERIALS AND METHODS. Forty human maxillary first premolar teeth were extracted for orthodontic purposes and divided into two main groups (n=20): Group A: monolithic traditional zirconia; Group B: monolithic translucent zirconia. The groups were further subdivided into two subgroups (n=10): (A1, B1) shoulder margin design; (A2, B2) feather-edge margin design. Teeth were prepared with either a 1 mm shoulder margin design or a feather-edge margin design. The prepared teeth were scanned using a digital intraoral scanner. The crowns were cemented using self-adhesive resin cement. All cemented teeth were stored in water for 7 days and thermocycling was done before testing. All samples were subjected to compressive axial loading until fracture. The fractographic analysis was done to assess the modes of fracture of the tested samples. RESULTS. The highest mean values of fracture resistance were recorded in kilo-newton and were in the order of subgroup A1 (2.903); subgroup A2 (2.3); subgroup B1 (1.854) and subgroup B2 (1.523). One-way ANOVA showed a statistically significant difference among the 4 subgroups. Concerning modes of fracture, the majority of samples in subgroups A1 and B1 were fracture of restoration and/or tooth, while in subgroups A2 and B2, the majority of samples fractured through the central fossa. CONCLUSION. Even though all the tested crowns fractured at a higher level than the maximum occlusal forces, the shoulder margin design was better than the feather-edge margin design and the monolithic traditional zirconia was better than the monolithic translucent zirconia in terms of fracture strength.

Superimposition: a simple method to minimize occlusal adjustment of monolithic restoration (디지털 장비의 중첩기능을 이용하여 단일체 수복물의 교합조정을 최소화한 증례)

  • Choi, Changhun;Kim, Sunjai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.253-258
    • /
    • 2016
  • The development of translucent zirconia enabled clinicians to choose a monolithic zirconia crown as one treatment modality in the posterior dentition. Careful occlusal adjustments are recommended for monolithic zirconia crowns because grinding zirconia inevitably causes phase transformation, which may deteriorate mechanical properties. intraoral scanners enable the clinician to scan and superimpose a complete tooth structure before preparation onto the prepared abutment. This technique helps to reproduce the original tooth form and occlusion of the patient. In this case report, prostheses were fabricated for patients with cracked or fractured tooth by applying intraoral scanner, Computer aided design-computer aided manufacturing (CAD-CAM) and monolithic zirconia crown to reproduce the occlusion of original tooth and to minimize occlusal adjustment. The clinical results were satisfactory in both esthetic and functional aspects.