• 제목/요약/키워드: modified electrodes

검색결과 245건 처리시간 0.029초

Nafion-EDTA가 수식된 유리탄소전극을 이용한 수은(II)의 측정 (Determination of Mercury(II) Using Nafion-EDTA-Modified Glassy Carbon Electrodes)

  • 정근호;박찬주;박율희;이지영
    • 한국환경보건학회지
    • /
    • 제26권4호
    • /
    • pp.110-114
    • /
    • 2000
  • Determination of mercury(II) using Nafion-EDTA-modified glassy carbon electrodes is proposed. it is based on the chemical reactivity of an immobilized modifier, Nafion-EDTA. Differential pulse voltammetry is employed, and the oxidation of complexes, at +0.43V vs. Ag/AgCl, is observed. For a 5-min preconcentration period, a linear calibration curve is obtained for mercury(II) concentrations ranging from 1.0$\times$ 10$^{-8}$ to 1.0$\times$10$^{-6}$ M. Further, when an approximate amount of copper(II) is added to the test solution, We demonstrate that at a preconcentration time of 5 min the Nafion-EDTA-modified glassy carbon electrode has a dynamic range of 2 orders of magnitude(from 10$^{-10}$ to 10$^{-8}$ M) and the detection limit is as low as 0.5$\times$ 10$^{-10}$ M(0.01 ppb). This method is applied to the determination of mercury(II) in sea water(4.0$\times$10$^{-10}$ M, 0.08ppb). The result agrees satisfactorily with the value(below 0.1 ppb) measured by using ICP/MS.

  • PDF

자기 집합 단분자막 개질 금 전극을 이용한 수용액 중 폴리피를 성장에 관한 In-situ EQCM 연구 (In-situ EQCM Study on Growth of Polypyrrole Films Using Gold Electrodes Modified with Self-Assembled Monolayers in an Aqueous Solution)

  • 서경자;전일철
    • 전기화학회지
    • /
    • 제5권3호
    • /
    • pp.143-152
    • /
    • 2002
  • Self-assembled monolayer(SAM)로 변형된 금 전극 위로 폴리피롤의 전기화학적 석출 과정을 수용액 상태에서 in-situ EQCM (Electrochemical Quartz Crystal Microbalance)과 ex-situ AFM (Atomic Force Microscopy)을 이용하여 조사하였다. 금 전극에서 cyclic voltammetry로 살펴본 폴리머의 석출은 산화 제한 전위 (anodic limiting potential) 값에 매우 의존적이었으며 주사 횟수에는 의존하지 않았다. 제한 산화 전위가 0.8V (vs Ag | ArCl) 이상일 때 폴리머의 석출은 크게 증가하였다. 그리고 주사 횟수가 증가하면서 질량의 비이상적 변화가 관찰되었는데 이것은 폴리피롤 필름의 rearrangement가 원인이라고 생각된다. 1-dodecanethiol SAM 전극과 thiophene SAM전극에서는 폴리머가 3차원적으로 성장하며 필름의 rearrangement를 수반하였지만 BPUS $(Bis(\omega(N-pyrrolyl)-n-undecyl)disulfide)$ SAM 전극에서는 2차원적인 layer-by-layer 성장을 하고 필름의 rearrangement는 관찰되지 않았다. 폴리머가 급격하게 전극 면으로 석출되면 사슬 모양과 도너츠 모양의 폴리머를 만들며, 정류 상태에 이르면서 주름잡힌 폴리머 필름이 생성되는 것이 원자 힘 현미경 (Atomic Force Microscopy) 이미지로 관찰되었다.

플라즈마 디스플레이 패널에서 공통전극에서의 벽전하를 이용한 기입방전특성의 향상 (Improvement of Address Discharge Characteristics Using Wall Charge on Common Electrodes in AC PDP)

  • 조병권
    • 전자공학회논문지
    • /
    • 제50권3호
    • /
    • pp.174-178
    • /
    • 2013
  • 플라즈마 디스플레이 패널에서 기입기간 동안 공통전극에서의 벽전하를 이용하여 기입방전특성을 향상시키기 위하여 수정된 구동 파형을 제시한다. 플라즈마 디스플레이의 구동방식에 있어서 초기화 기간 후에 상판의 두 전극에는 음전하가 쌓이게 되고 하판의 기입전극에는 양전하가 쌓이게 된다. 기입기간 중의 기입방전은 주사펄스와 기입펄스가 동시에 인가될 때 발생되는데 주사전극의 음전하와 기입전극의 양전하가 주로 이용된다. 반면에 공통 전극에서는 기입기간 동안 파형인가 없이 전압만 유지하기 때문에 공통전극의 벽전하는 크게 기여하지 않는다. 본 연구에서는 기입기간 중 주사 및 기입 펄스의 인가시각에 맞춰 공통 전극에서도 펄스를 인가하여 기입방전 특성을 조사하였다. 공통 전극에서의 인가전압의 높이와 펄스의 인가시각에 따른 기입 방전특성을 조사하는 실험을 각각 진행하였으며 그 결과 최적의 전압높이와 인가시각 조건하에서 기입방전의 발생시간을 종래보다 약 200 ns 정도 단축시켰다.

폴리피롤 막으로 변성시킨 유리질 탄소 및 백금 전극에서 Cr(Ⅵ) 이온의 정량 (Determination of Cr(Ⅵ) by Glassy Carbon and Platinum Electrodes Modified With Polypyrrole Film)

  • 유광식;우상범;정지영
    • 대한화학회지
    • /
    • 제43권4호
    • /
    • pp.407-411
    • /
    • 1999
  • 본 연구에서는 유리질 탄소전극과 백금 전극의 표면에 폴리피롤 막을 도포 시킨 PPy/GC 및 PPy/Pt 변성전극을 제조하고, 이들 변성 전극들을 작업전극으로 구성한 3-전극 장치를 이용하여 Cr(VI)의 정량분석을 시도하였다. 변성전극들은 +1.0V∼-1.0V를 50 mV/sec로 전위를 걸어주어 순환 전압 전류법으로 쉽게 제조할 수 있었으며, 26회 반복 주사함으로써 연구에 필요한 막의 두께를 조절하였다. PPy/GC 변성전극에서 Cr(VI)의 환원 반응은 +0.6V∼-0.5V(vs. Ag/AgCl)까지 넓은 범위에서 환원되는 경향을 보였으며,-0.25V(vs.Ag/AgCl)의 전위에서 최대 환원 봉우리를 가짐을 알 수 있었다. 이 전위에서 검량곡선을 조사한 결과, 0.1 ppm에서 60.0 ppm의 농도범위에서 기울기가 1.75 mA/ppm이고, 상관계수가 0.998인 좋은 직선관계를 가졌다. PPy/Pt 변성전극에서도 Cr(VI)의 환원 거동은 PPy/GC 변성전극과 유사하였으며, 검량곡선은 1.0 ppm∼60.0ppm의 농도범위에서 직선관계를 가졌다. 이때의 기울기와 상관계수는 각각 0.5 mA/ppm 및 0.923이었다. 그러나 선택성은 PPy/GC 변성전극이 약 3 배정도 우수하였다. PPy/GC 변성전극에서 Cu(II), As(III), pb(II) 및 Cd(II)등은 환원 경향을 보이지 않았으므로, Cr(VI)의 정량분석에는 방해하지 않았다.

  • PDF

콜로이드법으로 합성한 RuO2 전극촉매의 연구 (A Study on the RuO2 Electrode Catalyst Prepared by Colloidal Method)

  • 박진남
    • 한국수소및신에너지학회논문집
    • /
    • 제30권3호
    • /
    • pp.193-200
    • /
    • 2019
  • $RuO_2$, $PtO_2$, and various $(Ru,Pt)O_2$ colloidal solution were prepared using modified Watanabe method. Electrodes were manufactured by dipping of Ni mesh into the colloidal solution. Manufactured electrodes were characterized by XRD, SEM, and EDS. $(Ru,Pt)O_2$ electrodes showed $RuO_2$ crystal structure and high roughness. The hydrogen evolution reaction (HER) activities were evaluated by Linear Sweep Voltammetry. 1Ru2Pt electrode showed similar activity with commercial electrode, HER potentials are -0.9 V for both.

Comparisons of Stability and Spectral Response of n-Si Electrodes Modified with Polyaniline and Polypyrrole in Aqueous Solutions$^1$

  • Kim, Jin-Doo;Kim, Kang-Jin;Chon, Jung-Kyoon
    • Bulletin of the Korean Chemical Society
    • /
    • 제8권5호
    • /
    • pp.362-366
    • /
    • 1987
  • Modification of n-Si electrodes coated by photogalvanostatically with polyaniline and polypyrrole in aqueous solutions considerably enhanced the stability and the spectral response of the photoelectrodes. A polypyrrole coated electrode incorporated with redox couple $Fe(CN)_{6}^{3-_6}$ / $Fe(CN)_{6}^{4-_6}$ yielded a photocurrent density of 400${\mu}A/cm^2$ for about 120 hours. Broad spectral responses over 300-850 nm were observed for both polymer coated electrodes of which polypyrrole coated one showed better current conversion efficiency.

전기화학적인 방법을 이용한 탄소나노튜브 전극상의 오스뮴 착물의 고정화 및 혈당센서에 관한 응용 (Electrochemical Immobilization of Osmium Complex onto the Carbon Nano-Tube Electrodes and its Application for Glucose sensor)

  • 최영봉;전원용;김혁한
    • 전기화학회지
    • /
    • 제13권1호
    • /
    • pp.50-56
    • /
    • 2010
  • Multi-wall carbon nano-tube(MWCNT)를 이용해 screen printed carbon electrodes(SPCEs)을 제작하여 혈당센서의 선택성과 감도가 증가됨을 확인 할 수 있었다. 효소촉매반응을 위한 탄소전극으로의 전자이동의 매개체로 8족 금속 원소인 오스뮴을 중심금속으로 일차 아민을 포함하는 피리딘(pyridine) 리간드를 배위시켜 $[Os(dme-bpy)_2(4-aPy)Cl]^{+/2+}$를 합성하였다. 합성된 오스뮴 착물은 순환 전압전류법을 포함한 다양한 전기화학분석방법을 이용하여 전기적 성질을 조사하였다. 전기적 흡착방법을 이용하여 일차 아민을 갖는 착화합물을 전극위에 고정화 하였다. 오스뮴이 고정화된 MWCNT-SPCEs는 일반적인 carbon electrode보다 약 100배가량의 오스뮴이 흡착됨을 확인 할 수 있었다. (${\tau}_0=2.0\;{\times}\;10^{-9}\;mole/cm^2$) 마지막으로 당(Glucose)과 당 분해효소(Glucose Oxidase, GOx)에 의한 촉매반응의 전류를 확인하였고, 당 농도에 따라 선형 변화하는 전류의 양도 확인하였다.

섬유전극을 기반으로 한 라이프스타일 모니터링용 ECG-센싱의류의 프로토타입 연구 (A Study on a Prototype of ECG-Sensing ClothingBased on Textile Electrode for Lifestyle Monitoring)

  • 강다혜;조하경;송하영;조현승;이주현;이강휘;구수민;이영재;이정환
    • 감성과학
    • /
    • 제11권3호
    • /
    • pp.419-426
    • /
    • 2008
  • In order to develop "textile electrode - sensing clothing" which is a sort of smart clothing to measure electric activities of heart, we propose possible ways to develop textile electrode and design of sensing clothing, ultimately aiming to develop "ECG sensing clothing for lifestyle monitoring". Conventional sensors for measuring typical electric activities of heart keep certain distance between measuring electrodes to measure signals for electric activities of heart, but these sensors often cause inappropriate factors (e.g. motional artifacts, inconvenience of use, etc) for monitoring natural cardiac activities in our daily life. In addition, most of textile electrodes have made it difficult to collect data due to high impedance and unstable contact between skin and electrodes. To overcome these questions, we minimized distance between electrodes and skin to maximize convenience of use. And in order to complement contact between skin electrodes, we modified textile electrode's form and developed ways to design clothing. As a result, we could find out clinical significance by investigating possible associations of clinical electrocardiogram (ECG) with variation of distance between electrodes, and could also demonstrate clinically significant associations between textile electrode developed herein and clothing.

  • PDF

리튬 이차전지용 금속이 담지된 다공성 실리콘 음극물질의 전기화학적 특성 (Electrochemical Characteristics of Porous Modified Silicon Impregnated with Metal as Anode Materials for Lithium Secondary Batteries)

  • 장은정;전법주
    • 한국수소및신에너지학회논문집
    • /
    • 제23권4호
    • /
    • pp.353-363
    • /
    • 2012
  • The relationship between the diffusivity and electrochemical characteristics of lithium secondary battery with the modified Si anode material prepared in HF/$AgNO_3$ solution was investigated. The crystallographic structure and images of the modified porous Si and modified Si/Cu was examined using the X-ray diffraction, BET and SEM. To examine the effect of metal composite and pore size distribution according to chemical etching on the electrochemical characterization, the electrodes for half cells were prepared with the modified Si, modified Si/Cu, and modified Si/Cu annealed with $600^{\circ}C$. Our results showed that the chemical diffusivity of lithium ions was related to structure and resistance of Si/Cu composite anode material. The lithium diffusivity in modified silicon compound calculated from the CV was at the range of $1{\times}10^{-12}$ to $9{\times}10^{-16}cm^2/s$. The effects of modified silicon structure and resistance on the cycling efficiency were significant.