• Title/Summary/Keyword: misfiring

Search Result 50, Processing Time 0.037 seconds

A Study on the Improvement of the High Temperature Misfiring in AC PDP (AC PDP의 고온 오방전 개선에 관한 연구)

  • Choi, Joon-Young;Ham, Myung-Soo;Park, Chung-Hoo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.10
    • /
    • pp.1125-1131
    • /
    • 2004
  • Misfiring is usually observed at high ambient temperature in plasma display panel (PDP). This leads to bad image quality and limits the productivity of PDP industry. In this paper, experimental observations and improvement on the misfiring at high ambient temperature have been studied. In order to reduce the high ambient temperature misfiring different slope of ramp erase pulse corresponding to the temperature are applied. The experimental results show that the suggested method is quite effective for reducing the high temperature misfiring phenomena.

Monitoring of Misfiring Status of Ship Engines Using Minute Speed Changes in the Crankshaft (크랭크축의 미세속도변화를 이용한 선박엔진의 착화불량 상태 감시)

  • Kang, Ho Hyeon;Ahn, Jung Hwan;Kim, Hwa Young
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.51-56
    • /
    • 2022
  • In this study an efficient method for detecting and monitoring engine misfiring, focusing on minute speed changes in the crankshaft is proposed., Its validity is verified using various misfiring cases. Typically, the crankshaft speed fluctuates around the normal value depending on the engine misfiring status. Even a minute speed change in the crankshaft can be estimated by measuring the rotation time of each tooth of the 118-tooth flywheel attached to the crankshaft with a 2-MHz timer. Therefore, a speed pattern for an in-line six-cylinder engine consists of 236 tooth rotation speeds corresponding to the two rotations of the crankshaft, in which all the cylinders complete four-stroke cycle. FFT analysis can reduce the number of components of a speed pattern from 236 to just four major components: - fundamental frequency_(f), 2f, 3f, 6f., - This makes the comparison of the misfiring cases simpler and faster. In the experiment, five engine status cases (one normal firing and, four misfiring cases) were simulated. While the 6f component was the largest for the normal case, the f component increased as misfiring occurred one, two apart, and two consecutive times. The 3D FFT pattern comprising the ratio of f, 2f, and 3f, 6f showed that the distance between the misfiring and normal states was larger

A Study on the Reduction of the High temperature misfiring in AC PDP (AC PDP의 고온오방전 개선에 관한 연구)

  • Park, Cha-Soo;Choi, Joon-Young;Kim, Dong-Hyun;Lee, Hae-June;Lee, Ho-June;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1755-1758
    • /
    • 2004
  • Misfiring is often observed during the high temperature quality assurancetest of plasma display panel. This limits the productivity of PDP industry. In this paper, experimental observations on the misfiring at high panel temperature have been performed through time dependent discharge light output and static margin measurement. For the high temperature condition, firing voltage increment is found in both surface and facing discharges. This in turn increases lime lag in address discharge, and results m increment of misfiring probability. In order to reduce this kind of misfiring, a new method that applies automatically different slope of ramp erasing pulse on the common electrode according to temperature variation is proposed. The experimental results show that controlling the slope of ramp erasing pulse is quite effective for compensating temperature-dependent variation of reset and address discharge.

  • PDF

Study of AC-PDP's Discharge Characteristics with Variation time and Temperature in High Xe contents

  • Kim, Hyun-Gyu;Lee, Ho-Jun;Kim, Dong-Hyun;Park, Chung-Hoo;Cho, Sung-Yong;Ha, Chang-Seung;Wi, Sung-Suk;Sim, Choung-Hwan;Lee, Hae-June
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.732-735
    • /
    • 2009
  • In this paper, high Xe(Ne+Xe 10%, 20%, 30%) AC-PDP's discharge characteristics according to aging time were studied. The static margin, Vt close curve, discharge time lag was measured for experiments. According to increase of Xe partial pressure, the static margin and luminance was increased. As the result of analysis for misfiring probability, the misfiring is frequently occurred in accordance with increasing of aging time. To improve misfiring, we proposed 3Reset waveform and achieved misfiring probability which was improved.

  • PDF

A study on the compensation of misfiring by the method of ramp address voltage in AC PDP (AC PDP의 경사형 Address 전압 인가 방식에 의한 오방전 보상에 관한 연구)

  • Kim, J.Y.;Lee, S.J.;Kwon, B.D.;Kim, D.H.;Lee, H.J.;Park, J.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.149-152
    • /
    • 2002
  • If the ambient temperature rises for AC PDP, some of the discharge cells are turned off because of the misfiring during address period. Particularly, the misfiring of the 'last scan line is more serious than that of the first. In order to compensate the misfiring in such that case, different addressing voltage is applied at each cell such as progressively increasing pulse voltage instead of constant one. As a result, the addressing time and discharge charge of the last scan line have become similar to those of the first scan line and the phenomenon of misfiring has disappeared.

  • PDF

Effect of Working Gas Pressure on Misfirng of ac PDP at High Ambient Temperature

  • Ryu, Jae-Hwa;Choi, Joon-Young;Kim, Dong-Hyun;Kim, Joong-Kyun;Kim, Young-Kee;Lee, Ho-Jun;Park, Chung-Hoo
    • Journal of Information Display
    • /
    • v.4 no.4
    • /
    • pp.25-32
    • /
    • 2003
  • One of the important problems in ac PDP in recent years is the misfiring of ac PDP at high ambient temperatures which consequently degrades the image quality of the ac PDP. This may be due to the change of working gas pressure and/or MgO surface characteristics at high ambient temperatures. This paper deals with the effect of working gas pressure on the misfiring of ac PDP at high ambient temperature. From this study, we found that the main cause of the misfiring at high ambient temperature is the increase in discharge firing voltage induced by increased working gas pressure

New Selective Reset Waveform for a Large-Sustain-Gap Structure in AC PDPs (AC PDP의 장방전 구조의 구동을 위한 새로운 셀렉티브 리셋파형)

  • Song, Tae-Yong;Kim, Dong-Hun;Kim, Won-Jae;Lee, Seok-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1391-1392
    • /
    • 2007
  • A selective reset waveform which can improve the dark room contrast ratio in a large sustain gap structure is suggested in this paper. When conventional selective reset discharge is performed, frequent unexpected misfiring happens because of high Vxb and much quantity of negative wall charge formed on Y electrode during final sustain period. The misfiring between sustain electrode and address electrode can be removed by lowering Vxb value and the misfiring between address electrode and scan electrode can be prevented by applying last sustain pulse of 40us and rectangular pulse of Vscan on Y electrode. When the selective reset waveform has one time reset per 8 subfields, black luminance of 1.55 cd/m2 can be obtained without any misfiring.

  • PDF

Compensation of Addressing Time at High Temperature in ac PDP.

  • Choi, Joon-Young;An, Jung-Soo;Kim, Hun-Hee;Lee, Ho-Jun;Lee, Hea-Jun;Kim, Dong-Hyun;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.164-170
    • /
    • 2004
  • Misfiring is often observed during the high temperature quality assurance test of plasma display panel. This limits the productivity of PDP industry. In this paper, experimental observations on the misfiring at high panel temperature have been performed through time dependent discharge light output and static margin measurement. For the high temperature condition, firing voltage increment is found in both surface and facing discharges. This in turn increases time lag in address discharge, and results in increment of misfiring probability. In order to reduce this kind of misfiring, a new method that applies automatically different slope of ramp erasing pulse on the common electrode according to temperature variation is proposed. The experimental results show that controlling the slope of ramp erasing pulse is quite effective for compensating temperature-dependent variation of reset and address discharge.

  • PDF

A theoretical investigation of misfiring effects on the crankshaft torsional vibration of diesel engine (디젤기관 착화실패가 크랭크축계 비틀림 진동에 미치는 환경의 이론적 고찰)

  • 전효중;임영복
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.94-106
    • /
    • 1986
  • Since the oil shock of '70s the engine makers have developed new types of diesel engine with low fuel consumption. There is an obvious tendency towards the use of poorer quality fuels, such as the residual oil from chemical processes of refinery. The shaft driving generators is also widely adopted on behalf of the auxiliary diesel engines, which are driving on the expensive diesel oil and have high fuel oil consumption rates, and some mania propulsion diesel engines are equipped with reduction gear systems to get better propulsive efficiency by slower propeller revolutions. The propulsion shafting system equipped with the shaft driving generator or the geared diesel engine shafting system has flexible couplings, and it requires extensive investigations of the torsional vibration and torque fluctuation in order to ensure the acceptable operation range in service. The characteristics of misfiring must be especially examined for the high viscosity fuels to be used. Both torsional vibration and fluctuating torque resulted from misfiring, should be examined for thier effects on the flexible coupling and propulsion shafting system. This paper is to investigate and solve the above mentioned problems which must be predicted on the design-stage of marine propulsion shafting system. A computer program is developed to calculate the indicated diagram, fluctating torque and torsional vibration for both normal and misfiring conditions.

  • PDF

The effects of engine's misfiring condition on the dynamic behaviour of resilient mounting systems (엔진의 착화실패가 탄성지지계의 동적거동에 미치는 영향)

  • 손석훈;장민오;김성춘;김의간
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.188-193
    • /
    • 1996
  • The purpose of resilient mounting for marine engine is to prevent noise and ship damages caused by engine vibration. Although many researches for the resilient mounting system have been carried out, these results have limit to apply on the marine engine systems. Because marine engine generally have low speed operating range and have to consider misfiring condition. In this paper, we studied the effect of engine's misfiring on the resilient mounting systems. And the influences of design parameters, such as dynamic characteristics and location angles of resilient rubber mountings, were also examined on the single and double resilient mounting systems.

  • PDF