A Study on the Reduction of the High temperature misfiring in AC PDP

AC PDP의 고온오방전 개선에 관한 연구

  • Park, Cha-Soo (Department of Electrical Engineering, Pusan National University) ;
  • Choi, Joon-Young (Department of Electrical Engineering, Pusan National University) ;
  • Kim, Dong-Hyun (Department of Electrical Engineering, Pusan National University) ;
  • Lee, Hae-June (Department of Electrical Engineering, Pusan National University) ;
  • Lee, Ho-June (Department of Electrical Engineering, Pusan National University) ;
  • Park, Chung-Hoo (Department of Electrical Engineering, Pusan National University)
  • Published : 2004.07.14

Abstract

Misfiring is often observed during the high temperature quality assurancetest of plasma display panel. This limits the productivity of PDP industry. In this paper, experimental observations on the misfiring at high panel temperature have been performed through time dependent discharge light output and static margin measurement. For the high temperature condition, firing voltage increment is found in both surface and facing discharges. This in turn increases lime lag in address discharge, and results m increment of misfiring probability. In order to reduce this kind of misfiring, a new method that applies automatically different slope of ramp erasing pulse on the common electrode according to temperature variation is proposed. The experimental results show that controlling the slope of ramp erasing pulse is quite effective for compensating temperature-dependent variation of reset and address discharge.

Keywords