• Title/Summary/Keyword: medical radiation exposure

Search Result 605, Processing Time 0.025 seconds

The Effects of MRI on Mouse Embryos During Fetal Stage

  • Nakamura, Takashi;Ryu, Myung-Sun;Sakazaki, Takahiko;Itokawa, Yuka;Maenaka, Toshihiro;Masubuchi, Takashi;Sekimoto, Hiroyuki;Kanehara, Masayuki;Kang, Young-Nam;Gu, Yeun-Hwa
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.2
    • /
    • pp.91-96
    • /
    • 2006
  • The effects of Magnetic resonance imaging (MRI) on mouse embryos at the early stage of organogenesis were investigated. Pregnant ICR mice were exposed on day 8 of gestation to MRI at 0.5 T for 0.5 hour to 3 hours. The mortality rates of embryos or fetuses, the incidence of external malformations, fetal body weight and sex ratio were observed at day 18 of gestation. A significant increase in embryonic mortality was observed after exposure to either 0.5 T MRI for 0.5 hour or 2 hours. However, the exposure to MRI for 1 hour or 3 hours did not induce any significant increase in embryonic mortality when compared with control. External malformations such as exencephaly, cleft palate and anomalies of tail were observed in all experimental groups exposed to each MRI. A statistically significant increase of external malformations was observed in all groups treated with 0.5 T MRI for 0.5 hour and 3 hours. The incidence of external malformations in the mice group exposed to 0.5 T MRI for 0.5-hour was found to be higher than those of mice group exposed to 0.5 T MRI for 2 hours. The effects of MRI on the external malformations might not to be dose-dependent. There was no statistically significant difference in fetal body weight and sex ratio among each MRI exposure groups.

Measurement of Skin Dose Distribution for the Mobile X-ray Unit Collimator Shielding Device (이동형 X선 장치 차폐도구 제작을 통한 표면선량 분포 측정)

  • Hong, Sun-Suk;Kim, Deuk-Yong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.5-8
    • /
    • 2010
  • Opened a court in February 10, 2006, a rule of safety management of the diagnosis radiation system was promulgated for safety of the radiation worker, patients and patients' family members. The purpose of this rule is to minimize the risk of being exposed to radiation during the process of handling X-ray. For this reason, we manufactured shielding device of mobile X-ray unit collimator for diminution of skin dose. Shielding device is made to a thickness of Pb 0.375mm. For portable chest radiography, we measured skin dose 50cm from center ray to 200cm at intervals of 20cm by Unfors Xi detector. As a result, a rule of safety management of the diagnosis radiation system has been strengthened. But there are exceptions, such as ER, OR, ICU to this rule. So shielding device could contribute to protect unnecessary radiation exposure and improve nation's health.

  • PDF

Study on the Improvement of the Radiation Work Field Classification System in Republic of Korea (국내 방사선종사자 피폭 분류체계 개선에 관한 연구)

  • Su-Hui Park;Ji-Young Han;Yong-Min Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.267-275
    • /
    • 2023
  • Occupational exposure records are subject of global interest, and analysis of radiation workers in work categories is being conducted. In Rep. of Korea, according to relevant ministries, the MOHW(Ministry of Health and Welfare), the MAFRA(Ministry of Agriculture, Food and Rural Affairs), and the NSSC(Nuclear Safety and Security Commission) collect and analyze records of occupational exposure by dividing them into 11 work categories. However, this classification system lacks consistency with the systems of major countries, including the UNSCEAR(United Nations Scientific Committee on the Effects of Atomic Radiation). The domestic radiation work field classification system does not have clear classification criteria and does not reflect the characteristics of the radiation work field. Through the analysis of the classification system of the UNSCEAR, we suggested the five main categories(nuclear cycle, medical, industrial, others(education/research, military/public) field and several sub-categories according to each radiation work field.

A study of the radioprotection effect of guarana (Paullinia cupana) on the fetuses of ICR mice THE RADIATION PROTECTION EFFECTS OF GUARANA

  • Gu, Yeun-Hwa;Hasegawa, Takeo;Suzuki, Ikukatsu;Yamamoto, Youichi;Yoon, Yeog-Byung;Rhee, Soo-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.347-356
    • /
    • 2001
  • Guarana, a tropical plant is found in powdered for in health food and is very popular soft drink in Brazil as an energy feaster with its high caffeine contents. We examined its radioprotection effects during organogenesis stages of ICR mice by malformations rate and cellular lead 8 the embryo by radiation and analyzed the mechanism of the radioprotection effects in the fetal of ICR mice. The results of this study showed that Guarana reduced clearly the embryonic death rate and teratogenesis rate by radiation. Its radioprotection effect inject be related with its radioprotection effect might be related with its antioxidant effect or free radical scavenger. We need to exposure the Guarana as a potential radioprotection agent. Therefore, we investigated about radiation effects by Guarana using to mice experiments in this paper.

  • PDF

DNA Damage of Lymphocytes in Volunteers after 4 hours Use of Mobile Phone (일부 자원자들의 이동전화 4시간 연속 사용 후 림프구 DNA 손상 평가)

  • Ji, Seon-Mi;Oh, Eun-Ha;Sul, Dong-Geun;Choi, Jae-Wook;Park, Hee-Chan;Lee, Eun-Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.37 no.4
    • /
    • pp.373-380
    • /
    • 2004
  • Objectives : There has been gradually increasing concern about the adverse health effects of electromagnetic radiation originating from cell phones which are widely used in modern life. Cell phone radiation may affect human health by increasing free radicals of human blood cells. This study has been designed to identify DNA damage of blood cells by electromagnetic radiation caused by cell phone use. Methods : This study investigated the health effect of acute exposure to commercially available cell phones on certain parameters such as an indicator of DNA damage for 14 healthy adult volunteers. Each volunteer during the experiment talked over the cell phone with the keypad facing the right side of the face for 4 hours. The single cell gel electrophoresis assay (Comet assay), which is very sensitive in detecting the presence of DNA strand-breaks and alkali-labile damage in individual cells, was used to assess peripheral blood cells (T-cells, B-cells, granulocytes) from volunteers before and after exposure to cell phone radiation. The parameters of Comet assay measured were Olive Tail Moment and Tail DNA %. Results : The Olive Tail Moment of B-cells and granulocytes and Tail DNA % of B-cells and granulocytes were increased by a statistically significant extent after 4-hour use of a cell phone compared with controls. Conclusion : It is concluded that cell phone radiation caused the DNA damage during the 4 hours of experimental condition. Nonetheless, this study suggested that cell phone use may increase DNA damage by electromagnetic radiation and other contributing factors.

A Study on the Measurement Linearity of Photoluminescent Dosimeter (형광유리선량계의 계측 직선성 연구)

  • Jeong, Kyeong-Hwan;Jung, Dong-Kyung;Seo, Jeong-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.841-847
    • /
    • 2021
  • Related institutions that use radiation are diverse in Korea, such as research, medical care, and education. Recently, the number of examinations and visits to medical institutions is increasing. As a result, the number of radiological examinations in medical institutions is increasing. Radiation safety management is necessary as well as exposure of radiation workers. For safety management, first of all, it is necessary to wear the personal exposure dosimeter correctly and measure it accurately after wearing it. This study tries to evaluate and verify the measurement straightness of PLD devices by radiation of a diagnostic generator. Radiation division irradiation time interval was measured after irradiating 10 times at 10, 30, and 60 sec and irradiating the irradiation distance from 30 to 100 cm at 10 cm intervals to measure the change in absorbed dose depending on the distance. As a result, there was no difference in absorbed dose by time interval. This is considered to be helpful in various studies by using a diagnostic generator for the study of high absorbed dose.

Factors Influencing Protective Behavior against Radiation Exposure of Radiological Technologist in Computed Tomography Examination Room (전산화단층촬영검사실 방사선사의 방사선피폭 방어행위에 영향을 미치는 요인 분석)

  • Kim, Ki-Jeong;Jung, Hong-Ryang;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.581-586
    • /
    • 2018
  • This study was conducted to analyze factors Influencing Protective Behavior against Radiation Exposure using questionnaires for 231 radiological technologists working in Computed Tomography(CT) examination room with high radiation dose in diagnostic radiology field. Statistical analysis of the collected data revealed that the reasons for partially shielding the examination part in the CT scan were the lack of protective equipment, securing of radiation justification, being annoying and maybe not being harm to adults in order. It was also revealed that the variables influencing the protective behavior were protective behavior against radiation harm, self-efficacy, protective environment, organization culture, protective knowledge and protective instrument in order. The higher the radiological protective environment(${\beta}=0.245$) and the lower the radiological protective knowledge(${\beta}=-0.034$), the more influential the protective behavior against radiation harm was. In this study, it was shown that non examination parts were not shielded in the CT scan. Therefore, it is necessary to improve the level of protective environment, to cultivate knowledge to improve the protective behavior against radiation harm and to have an intervention strategy for concrete action.

A Study on the Performance Evaluation of Portable Radiation Shielding Apparatus (이동형 방사선 차폐장치의 성능평가에 관한 연구)

  • Koo, Bon-Yeoul;Han, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.41 no.4
    • /
    • pp.289-295
    • /
    • 2018
  • When using a mobile X-ray unit, primary radiation creates medical images and secondary radiation scatters in many directions, which reduces image quality and causes exposure to patients, care givers and medical personnel. The purpose of this study was to develop a radiation shielding system for effectively shielding secondary radiation and evaluate its effectiveness. Using a mobile X-ray unit, spatial dose according to presence of human equivalent phantom and spatial dose using the developed shielding device were measured, and the phantom at 80 cm equidistance from center of X-ray was compared with spatial dose according to use of a shield. Measurements were taken at intervals of 10 cm every $30^{\circ}$ from the head direction($-90^{\circ}$) to the body direction($+90^{\circ}$). In the spatial dose measurement with and without the phantom, when the human equivalent Phantom was used, the spatial dose was increased by 40% in all directions from 40 cm to 100 cm from the central X-ray, and about 88% of the space dose was reduced when using the developed shields with the phantom. The equidistance dose at 80 cm from the central X-ray was increased by 39% from $5.1{\pm}0.26{\mu}Gy$ to $7.1{\pm}0.15{\mu}Gy$ when the human equivalent phantom was used, and when phantom was used and shielding was used, the spatial dose was reduced by about 90% from $7.1{\pm}0.15{\mu}Gy$ to $0.7{\pm}0.07{\mu}Gy$. The spatial dose of natural radiation was measured to be about $0.2{\pm}0.04{\mu}Gy$ when using the developed shielding with Phantom at a distance of 1 m or more. It is expected that by using the developed shielding system, it will be possible to effectively reduce secondary radiation dose received in all directions and to ensure safe imaging.

An Accidental over Exposure in Mednif Tele-Cobalt Machine in Nepal

  • chaurasia, P.P.;Srivastava, R.P.;Prasiko, G.;Neupane, B.P.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.97-99
    • /
    • 2002
  • A radiation incident took place during treatment on MEDNIF Tele cobalt-60 therapy machine in B.P.KOIRALA MEMORIAL CANCER HOSPITAL in Bharatpur, Nepal. This Chinese made machine has activity of 6240 Curies of cobalt -60. This machine has fulfilled safety requirements. ICRP recommendations, safety rules are followed and practiced. The source was struck up during treatment and a technician was exposed to equivalent dose of 13.75 mSv. recorded by Personal film badge. Risks of workers are comparable to other safe industries. All exposures shall be kept as low as reasonably possible. The higher level of safety is achieved only when every one is dedicated to common goal. A lesson is learnt for future. Good practice is essential but not sufficient. A high demand for tele Cobalt therapy convinced management to replace Mednif machine with a new efficient Elite Tele Cobalt theratron Machine.

  • PDF

Research on the Hematological Changes in Accordance with Radiation Dose and Radiation Exposure period of the Medical Radiation Workers (의료 방사선 종사자의 피폭기간 및 피폭선량과 혈액성분 변화에 대한 조사)

  • Cho, Jihwan;Jin, Seongjin;Park, Cheolwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.495-502
    • /
    • 2016
  • In this study, we analyzed the effects of radiation exposure, as compared to the hematological parameters change of medical radiation workers and the public. The mean value of all hematological parameters were in the normal range. Eosin mean value of the radiation workers($2.52{\pm}1.79%$) showed that a significantly lower than the control group($2.92{\pm}1.39%$). In the comparison of the results depending on the occupation period, it showed high value that the mean of the radiation workers group WBC, platelet, Lymph, Mono, Baso. Over 20 years of radiation workers WBC, Mono showed low values and less than 10 years of radiation workers mean value of Baso showed low values, there was no statistical significance. In the comparison of the results depending on the 4 years cumulative radiation dose, Over 5.0 mSv of Radiation works RBC($4.61{\pm}0.53$ vs $4.91{\pm}0.38$), Hct($41.51{\pm}4.07$ vs $43.97{\pm}3.40$), Eosin($1.74{\pm}1.14$ vs $2.92{\pm}1.39$) showed low value, it was statistical significance. 0.5~1.0 mSv radiation exposure workers Hb ($13.93{\pm}1.75$) showed a significantly lower value than that of the control group ($14.90{\pm}1.29$).