• 제목/요약/키워드: medical imaging system

검색결과 922건 처리시간 0.042초

의료영상장치의 전자파 안전에 대한 연구 (A Study on the Safety of Electromagnetic Wave of Medical Imaging System)

  • 선종률;이원정;임재동
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 추계학술대회
    • /
    • pp.103-112
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system ($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.

  • PDF

의료영상장치의 전자파 안전에 대한 연구 (A Study on the Safety of Electromagnetic Wave of Medical Imaging System)

  • 선종률;이원정;임재동
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.67-72
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic(USG) system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic(R/F) system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.

HIGH RESOLUTION IMAGING IN 37 MRI SYSTEM

  • Park, Jeong-Il;Choi, Kim-S.;Choe, Bo-Young;Suh, Tae-Suk;Lee, Hyoung-Koo;Shin, Kyung-Sub;Lee, Heung-Kyu
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 1999년도 Japanese Journal of Medical Physics
    • /
    • pp.423-424
    • /
    • 1999
  • PDF

HIGH QUALITY $^1$H SPECTROSCOPY ON 3.0T MRI

  • Kim, Tae-Yong;Kim, S. Choi;Lee, Heung-Kyu;Park, Jeong-Il;Choe, Bo-Young;Suh, Tae-Suk;Lee, Hyoung-Koo;Shinn, Kyung-Sub
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 1999년도 Japanese Journal of Medical Physics
    • /
    • pp.172-173
    • /
    • 1999
  • PDF

CCD Camera 기반 실시간 방사선치료조사면 검증 시스템 개발 및 화질개선을 위한 기초연구 (System Development and Fundamental Study of CCD Camera Based Electronic Portal Imaging Device)

  • 장기원;박지군;이동길;김진영;남상희;하성환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.380-383
    • /
    • 2003
  • The purpose of this study is to develope prototype EPID system and improve image quality of radiation therapy field imaging system using CCD camera. For this research we used Linac(Clinac 4/100), Copper metal plate, $Gd_2O_2S_2$ phosphor and CCD camera(Photronic). In this study we find best thickness of buil-up metal plate and acquired projection image of humanoid head phantom. Also we enhanced raw image data using superposition and histogram stretching method. Through the thickness optimized of metal plate and image processing, we confirmed of an improved image quality of an EPID system using CCD camera. As result, highest quality image was acquired at 1mm thickness of Copper metal plate and improved image quality by image processing methods.

  • PDF

스마트 기기용 의료 콘텐츠를 위한 영상 가시화 시스템 (Medical Contents Visualization System for Smart Device)

  • 권구주;강동수;고영인;신병석
    • 한국멀티미디어학회논문지
    • /
    • 제15권10호
    • /
    • pp.1264-1272
    • /
    • 2012
  • 3차원 볼륨렌더링 방법은 인체의 외형뿐만 아니라 내부의 모습도 투과하여 보여줄 수 있기 때문에 의료영상 분야에서 널리 사용된다. 기존의 의료영상 장비는 볼륨렌더링 방법을 이용하여 다양한 3차원 영상을 제공하고 있다. 최근 의료영상 분야에서는 휴대성의 장점을 가진 스마트 기기를 도입함으로써 기존 의료영상 분야의 결과물을 의사와 환자들 사이에서 소통이 원활하게 하려는 연구가 활발히 진행되고 있다. 본 논문에서는 비교적 저 사양인 휴대용 스마트 기기에서 3차원 볼륨데이터를 가시화하기 위하여 2차원 텍스쳐를 활용하는 방법을 제안하고 다양한 2차원, 3차원 진단영상을 제공하는 휴대용 의료영상 가시화 시스템을 제안한다.

Subjective Imaging Effect Assessment for Intelligent Imaging Terminal Design: a Method for Engineering Site

  • Liu, Haoting;Lv, Ming;Yu, Weiqun;Guo, Zhenhui;Li, Xin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권3호
    • /
    • pp.1043-1064
    • /
    • 2020
  • A kind of Subjective Imaging Effect Assessment (SIEA) method and its applications on intelligent imaging terminal design in engineering site are presented. First, some visual assessment indices are used to characterize the imaging effect: the image brightness, the image brightness uniformity, the color image contrast, the image edge blur, the image color difference, the image saturation, the image noise, and the integrated imaging effect index. A linear weighted function is employed to carry out the SIEA computation and the Analytic Hierarchy Process (AHP) technique is used to estimate its weights. Second, a SIEA software is developed. It can play images after the settings of assessment index or assessment reaction time, etc. Third, two cases are used to illustrate the application effects of proposed method: the image enhancement system design for surveillance camera and the imaging environment perception system design for intelligent lighting terminal. A Prior Sequential Stimulus (PSS) experiment is proposed to improve the evaluation stability of SIEA method. Many experiment results have shown the proposed method can realize a stable system design or parameters setting for the intelligent imaging terminal in engineering site.

Super-spatial resolution method combined with the maximum-likelihood expectation maximization (MLEM) algorithm for alpha imaging detector

  • Kim, Guna;Lim, Ilhan;Song, Kanghyon;Kim, Jong-Guk
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.2204-2212
    • /
    • 2022
  • Recently, the demand for alpha imaging detectors for quantifying the distributions of alpha particles has increased in various fields. This study aims to reconstruct a high-resolution image from an alpha imaging detector by applying a super-spatial resolution method combined with the maximum-likelihood expectation maximization (MLEM) algorithm. To perform the super-spatial resolution method, several images are acquired while slightly moving the detector to predefined positions. Then, a forward model for imaging is established by the system matrix containing the mechanical shifts, subsampling, and measured point-spread function of the imaging system. Using the measured images and system matrix, the MLEM algorithm is implemented, which converges towards a high-resolution image. We evaluated the performance of the proposed method through the Monte Carlo simulations and phantom experiments. The results showed that the super-spatial resolution method was successfully applied to the alpha imaging detector. The spatial resolution of the resultant image was improved by approximately 12% using four images. Overall, the study's outcomes demonstrate the feasibility of the super-spatial resolution method for the alpha imaging detector. Possible applications of the proposed method include high-resolution imaging for alpha particles of in vitro sliced tissue and pre-clinical biologic assessments for targeted alpha therapy.

형광과 레이저 스펙클 대조도 이미징을 결합한 실시간 의료영상 시스템 개발 (Development of a Real-time Medical Imaging System Combined with Laser Speckle Contrast Imaging and Fluorescence Imaging)

  • 심민재;김이근;고택용;최진혁;안예찬
    • 대한의용생체공학회:의공학회지
    • /
    • 제42권3호
    • /
    • pp.116-124
    • /
    • 2021
  • It is important to differentiate between the target tissue (or organ) and the rest of the tissue before incision during surgery. And when it is necessary to preserve the differentiated tissues, the blood vessels connected to the tissue must be preserved together. Various non-invasive medical imaging methods have been developed for this purpose. We aimed to develop a medical imaging system that can simultaneously apply fluorescence imaging using indocyanine green (ICG) and laser speckle contrast imaging (LSCI) using laser speckle patterns. We designed to collect images directed to the two cameras on a co-axial optical path and to compensate equal optical path length for two optical designs. The light source used for fluorescence and LSCI the same 785 nm wavelength. This system outputs real-time images and is designed to intuitively distinguish target tissues or blood vessels. This system outputs LSCI images up to 37 fps through parallel processing. Fluorescence for ICG and blood flow in animal models were observed throughout the experiment.

Molecular imaging of atherosclerosis using reporter gene system

  • Yoo, Ran Ji;Lee, Kyochul;Kang, Joo Hyun;Lee, Yong Jin
    • 대한방사성의약품학회지
    • /
    • 제4권1호
    • /
    • pp.26-31
    • /
    • 2018
  • Macrophages play a key role in atherosclerotic plaque formation, but their participation has been discerned largely via ex vivo analyses of atherosclerotic lesions. Therefore, we aimed to identify atherosclerosis on noninvasive in vivo imaging using reporter gene system. This study demonstrated that recruitment of macrophages could be detected in atherosclerotic plaques of Apolipoprotein E knockout (ApoE-/-) mice with a sodium iodide symporter (NIS) gene imaging system using $^{99m}Tc-SPECT$. This novel approach to tracking macrophages to atherosclerotic plaques in vivo could have applications in studies of arteriosclerotic vascular disease.