A Study on the Safety of Electromagnetic Wave of Medical Imaging System

의료영상장치의 전자파 안전에 대한 연구

  • Received : 2010.10.20
  • Accepted : 2010.12.07
  • Published : 2010.12.31

Abstract

This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic(USG) system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic(R/F) system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.

Keywords

References

  1. 김진석외, "전자파의 인체위해 조사연구", 전자파기술학회지, 제4권1호,(1993)pp84-85
  2. 김기채, "전자파에의한 산업기기의 오동작과 인체장해", 대한전기학회논문, 42권 2호(1993)pp5-11
  3. 강태원외, "의료기기의 전자파 적합성", 한국전자파학회지, 제16권3호,(2005) pp80-87
  4. 고신관외 " 방사선물리학"고문사, (1997)p71
  5. 이준화외, "의료기관내 전자파환경 실태와 그 영향(I)." 의학물리학회지,8-1(1997)pp:53-54
  6. 이상석외. "의료방사선생물학" 정문각(1999)pp444-454
  7. 산업자원부 고시 제 2006-65호('06.7.4) '전기설비기술기준' 제17조
  8. 정보통신부 고시 제2001-88호 '전자파 인체 보호기준' 제3조
  9. WHO 국제비전리방사선보호위원회(ICNIRP)의 국제권고기준
  10. Mack, W., Preston-Martin, S., and Peters,J.M., "Astrocytoma Risk related to Job Exposure to Electric and Magnetic Fields", Bioelectromagnetics, 12(1):pp.57-66,
  11. 森山節二(譯), "無線周波數およびマイクロウェ-ブ の生體,環境建築其準と安全對策", (1984)pp19-20