• Title/Summary/Keyword: medical electrical equipment

Search Result 110, Processing Time 0.039 seconds

Analysis of Medical Image with CD-RAD Phantom (CD-RAD Phantom을 이용한 의료영상의 분석)

  • Kim, Chang-Bok;Kim, Young-Keun;Cho, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.369-369
    • /
    • 2007
  • The physical and visual evaluation of the identical X-rays are analyzed for medical image clarity with CD-RAD Phantom on this study. The method of measurement is to research CD-RAD by X-rays and to acquire images through image processing equipment, the image analyses are carried out by physical evaluation with statistical method through CD-RAD analyser program, and the visual evaluation of the identical X-rays is carried out by blind test for 20 observers. The result of it is that IQF value of the physical evaluation of Contrast-detail curve is 25 and IQF value of the visual evaluation is 30, so it is revealed that the physical evaluation is superior to the visual one. The special qualities of medical images have much importance of the transmission capacity of information to the image analyser, so it is concluded that 0비ective methods of the physical and visual analyses should be carried out side by side.

  • PDF

An Open Bridcage RF coil for Magnetic Rresonance Imaging (자기공명영상을 위한 개방형 새장 고주파코일)

  • Lee, S.Y.;Yi, J.H.;Yi, W.;Mun, C.W.;Cho, M.H.
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.5
    • /
    • pp.42-47
    • /
    • 1998
  • Bridcage RF coil is one of the most widely used RF coils in MRI. In order to use birdcage RF coils in open MRI systems, an open tructured birdcage RF coil has been investigated. By opening the ring structure of an original birdcage RF coil and driving the coil at two opening ends, the original birdcage RF coil can be modified to an open structured coil. In order to improve magnetic field uniformity of the open birdcage RF coil, driving voltage phases at the two opening ends can be controlled to be in-phase or out-of-phase each other. Operating frequency of the open birdcage RF coil has been theoretically derived, and the theoretical derivation has been verified by experiments.

  • PDF

The Standard of procedures for performance test of intended equipment for heating in home-healthcare medical use (홈헬스케어용 온열기기의 성능평가를 위한 표준시험방법 연구)

  • Park, Su-Kang;Kim, Jae-Hwan;Kim, Yong-Sung;Yoo, Sun-Kuk;Kang, Yeong-Gyu;Jeong, Hui-Gyo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1986_1987
    • /
    • 2009
  • 홈헬스케어용으로 사용되는 온열기기의 오동작이나 안전사고에 대한 예방으로 품질향상과 안전성확보가 필요하며 이를 위한 시판전의 시험검사나 시판후의 수거검사시에 성능시험과 안전장치검사가 필요하다. 본 논문에서는 개인용온열기의 안전성 확보와 성능평가를 위한 표준시험방법을 연구하였다.

  • PDF

The standard of procedures for essential safety test of personal medical equipment (개인용의료기기의 필수안전시험을 위한 표준시험방법 연구)

  • Park, Su-Kang;Nam, Ki-Il;Kim, Heung-Seuk;Kim, Yong-Kyun;Lim, Il-Gwon;Park, Sang-Gun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1984_1985
    • /
    • 2009
  • 개인용의료기기는 오동작이나 부작용에 대한 예방으로 품질향상과 안전성확보가 필요하며 이를 위한 시판전의 시험검사나 시판후의 수거검사시에 안전성평가를 위한 표준시험방법 개발이 필요하다. 본 논문에서는 개인용의료기기의 전기 및 기계적 안전성 평가를 위한 필수안전시험에 대한 표준시험방법을 연구하였다.

  • PDF

4-channel Light Medical Therapy Apparatus for External Injury Cure (체외 상처 치유를 위한 4-채널 광 치료기)

  • Cheon, Min-Woo;Kim, Seong-Hwan;So, Keum-Young;Moon, Young-Lae;Mun, Seong-Pyo;Park, Yong-Pil;Lee, Ho-Sik;Kim, Tae-Gon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.8
    • /
    • pp.731-735
    • /
    • 2007
  • We developed the 4channel Light Medical Therapy Apparatus for External Injury Cure using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on, Especially, to control the light irradiation frequency, FPGA was used, and to control the change of output value, TLC5941 was used. Control stage is divided into 4 levels by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and the output of a high brightness LED could be controlled stage by stage. Compared with one LED irradiation, several LEDs irradiation could increase optical power.

Study of Circuit Analysis & Application for Isolated Power System for the Medically Used Rooms (의료실의 비접지 배선방식 회로해석 및 적용에 관한 연구)

  • Oh, Cheong-Hwan;Kim, Young-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.87-93
    • /
    • 2005
  • Today, the sciences in medical and nursing fields are becoming progressively more dependent on electrical apparatus for the preservation of life of hospitalized patients. Therefore, it is required more safety medical power distribution system in order to protect patients and physicians more securely from unexpected leakage of current. Especially for the medically used rooms which use life sustaining equipment power should be provided as supplying continuously without interrupting with lowest leakage current. This thesis proposed the reason why Isolation Power System is safety through the circuit analysis and applications.

X-선 발생장치 정류방식에 따른 출력특성에 관한 연구

  • Na, Gil-Ju;Baek, Su-Ung;Yang, Hyeon-Hun;Park, Gye-Chun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.126-126
    • /
    • 2009
  • X-ray high-voltage generator is the most important part that can decide the radiation exposure dose affecting a patient or operator according to the characteristic. If decrease of X-ray radiation exposure dose and output characteristic of high-voltage generator is unstable, a patient or operator must be exposed to more radiation. This study measures and analyzes the exposure dose reproducibility and output characteristic according to a change of tube current on the various rectification methods of diagnostic X-ray equipment. It can find that quality bastardize and output is increased if voltage of X-ray tube is increased. Exposure dose reproducibility according to output of X-ray equipment is extremely excellent in inverter type, and is stable in order of following three-phase, a single-phase and condenser method. This study can find that the reply incidence of high-voltage generator is generated due to difference in rectification method, noise occurs in X-ray due to that, quality of an image is decreased due to that, and medical diagnosis can be failed due to that.

  • PDF

The effect of infrared rays diode irradiation on collagen formation (적외선 레이저 다이오드가 콜라겐 형성에 미치는 영향)

  • Kim, Tae-Gon;Kim, Toung-Pyo;Lee, Ho-Sic;Park, Yong-Pil;Cheon, Min-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.411-411
    • /
    • 2009
  • Low level laser therapy has various therapy effects. This paper performed the basic study for developing the Low Level Laser Therapy Equipment for medical treatment. The apparatus has been fabricated using the laser diode and microprocessor unit. This equipment was fabricated using a micro-controller and a laser diode, and designed to enable us to control light irradiation time, frequency and so on. In this study, the designed device was used to find out how infrared laser diode affected the collagen formation. For in-vivo test, a round wound 1cm in diameter was cut from the test animal whose epidermal and dermal layers were removed. Test animals were relieved for 24 hours after wounds had been excised and then the infrared laser irradiation group was given irradiation therapy over 9 days one 20 min per day. As a result, More collagenosis occurred in the order of infrared laser irradiation and non-irradiation group. Collagenosis is closely related to wound repair and it was found that infrared laser irradiation groups had more collagenosis and was quicker to recover from wound than non-irradiation group.

  • PDF

The effect of 3mW 850nm Laser Diode on RAT BM-cell (3mW 850nm Laser Diode가 Rat BM-Cell에 미치는 효과)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.514-515
    • /
    • 2008
  • Low level laser therapy has various therapy effects. This paper performed the basic study for developing the Low Level Laser Therapy Equipment for medical treatment. The apparatus has been fabricated using the laser diode and microprocessor unit. This equipment was fabricated using a micro-controller and a laser diode, and designed to enable us to control light time, frequency and so on. In this study, the designed device was used irradiation to find out how 850 nm laser diode affected the cell proliferation of RAT bone-marrow cells. Experiment was performed to irradiation group and non-irradiation group for Rat bone marrow cells. MTT assay method was chosen to verify the cell increase of two groups and the effect of irradiation on cell proliferation was examined by measuring 590 nm transmittance of micro plate reader. As a result, the cell increase of Rat bone marrow cells was verified in irradiation group as compared to non-irradiation group. The fact that specific wavelength irradiation has an effect on cell vitality and proliferation is known through this study.

  • PDF