• Title/Summary/Keyword: measurement table

Search Result 454, Processing Time 0.028 seconds

A Study of the Measurements System in Electron Beam Welding (전자빔 용접 측정 시스템에 관한 연구)

  • Hong MinSung;Kim JongMin
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.258-263
    • /
    • 2005
  • Because of its high performance and accuracy, electron beam welding has an important role in industrial applications such as semi-conductor and LCD manufactures. Since its operation has been done in a vacuum room, it is very difficult to check out their weldability as well as the correct welding area of the specimen. In this study, a measurement system of the electron beam welding has been developed based on the 3-axis LVDT controlled table. In addition, the algorithm to tracking the welding line has been developed. Welded regions were measured by using an A-scan ultrasonic sensor only. Weldability of the aluminum specimen has been tested by newly developed measuring system. The results are compared with those by using an C-scan ultrasonic sensor, which show good agreements with each other.

  • PDF

A Method of Boresight Error Compensation for Missile Radome (유도탄용 레이돔 시선각 오차 보정 기법)

  • Kim, Gwang-Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.8 no.3 s.22
    • /
    • pp.56-63
    • /
    • 2005
  • The radome boresight error degrades the microwave seeker ability and the missile guidance performance. It increases the miss distance, also. This paper propose a method of radome boresight error measurement and compensation. The compensation method consist of radome analysis and radome compensation. In the radome analysis stage, we can know that the electromagnetic characteristics distorted by radome. In the compensation stage, the look-up table is built and used for compensation. The test uses a FMS(Flight motion simulator) and adjusts the FMS setup error for more accuracy. The result shows that not using an elaborate radome measurement equipment, the radome boresight error is well compensated easily.

Shaking Table Test for Comparison of Seismic Performance of Concrete-Face Rockfill Dam and Earth Core Rockfill Dam (표면차수벽형 석괴댐과 락필댐의 내진성능 비교를 위한 진동대시험)

  • Ha, Ik-Soo;Lim, Eun-Sang;Seo, Min-Woo;Kim, Yong-Seung
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.3-10
    • /
    • 2005
  • In this study, 1-g shaking table tests on the model of CFR(Concrete-Face Rockfill) type "D" dam in operation and the model of virtual ECRD(Earth Core Rockfill Dam) of which static stability is about the same compared to the model of CFRD were carried out. The purpose of this study is to compare the seismic performance of CFRD and ECRD from the analysis of model test results. Displacement response behavior of the dam was examined through the measurement of vertical and horizontal displacement of model dam crest. Also, amplification characteristics of accelerometers installed with dam height were examined through the measurement of acceleration with dam height. Also, in the case of ECRD, patterns of excess pore pressure generation with dam height were examined. From the test results, it was found that accelerations of dam crest of CFRD and ECRD were amplified about 1.52 times and 2 times compared to the accelerations of dam bottom, respectively. amplification was outstanding at three quarters of dam height from the bottom of dam. This phenomenon was outstanding in case of ECRD. And it was estimated that vertical and horizontal displacement of prototype dam of CFRD were 6.8cm (0.1% of dam height) and 12.3cm (0.2% of dam height), respectively. Also, it was estimated that vertical and horizontal displacement of prototype dam of ECRD were 4.3cm (0.1% of dam height) and 5.5cm (0.11% of dam height), respectively.

  • PDF

Measurement of Association of Categorical Data Using The Overlapped Mosaic Plot : Dynamic Graphics Approach for $2{\times}2$ Contingency Table ($2{\times}2$ 분할표에서 동적 그래픽스로 구현된 겹쳐진 모자익 그림을 이용한 범주형 자료의 연관성 측정)

  • Yoon, Yeo-Chang;Oh, Min-Gweon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.10 no.2
    • /
    • pp.457-464
    • /
    • 1999
  • In this paper, we propose an overlapped mosaic plot which proposed by Hartigan and Kleiner(1981) represents the counts in $2{\times}2$ contingency table directly by tiles whose area is proportional to the cell frequency. Overlapped mosaic plot provides some measurements of association including dynamic graphics for mosaic plots. Dynamic graphics for mosaic plots give some useful informations when one gets some measurements of association and selects a model, and current statistical software does not provide this feature. We can see the deviations between observation and estimate of independence from overlapped mosaic plot. This dynamic graphics give some useful informations how far this data are apart from independence.

  • PDF

Comparison Between Performance of a Sound-Triggered Measurement and an Amplitude-Triggered Measurement in Shaking Table Tests (진동대를 이용한 모바일 진동 계측 기기의 사운드 트리거 계측과 진폭 트리거 계측 성능 비교)

  • Mapungwana, S.T.;Lee, Jong-Ho;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.1
    • /
    • pp.117-126
    • /
    • 2019
  • Micro-Electro-Mechanical Systems (MEMS) sensors have been widely used in Structural Health Monitoring due to their convenience and lower costs in comparison to conventional sensors. Triggered measurements are relevant in events such as earthquakes because unlike continuous measurements, they only record the structural response once an event happens. This is more cost effective and it makes the data more manageable because only the required measurements from the event are recorded. The most common method of triggering is amplitude triggering. However, lower input amplitudes (less than 0.1g) cannot be triggered by using this method. In this paper, sound triggering was introduced to allow triggered measurements for lower input amplitude values. The performance of the sound triggering and amplitude triggering were compared by a series of shaking-table tests. It was seen that sound-triggering method has a wider frequency (0.5~10Hz) and amplitude (0.01~1.0g) range of measurements. In addition, the sound triggering method performs better than the amplitude triggering method at lower amplitudes. The performance of the amplitude triggering, in terms of the triggering being simultaneous improves at higher input amplitudes.

Digital Position Measurement with MLPE of PET detector using a Small Number of Photosensors (적은 수의 광센서를 사용한 PET 검출기의 최대우도함수를 적용한 디지털 위치 측정)

  • Kang, Seunghun;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.151-156
    • /
    • 2022
  • A detector using a small number of photosensors was designed, and the position of a scintillation pixel that interacted with gamma rays through a maximum likelihood position estimation(MLPE) was measured as a digital position. For this purpose, simulation was performed using DETECT2000, which can simulate the movement of light within the scintillator, and the accuracy of position measurement was evaluated. A detector was configured using a 6 × 6 scintillation pixel array and 4 photosensors, and a gamma ray event was generated at the center of each scintillation pixel to create a look-up table through the ratio of acquired light. The gamma-ray event generated at the new position was applied as the input value of the MLPE, and the positiion of the scintillation pixel was converted into a digital positiion after comparison with the look-up table. All scintillation pixels were evaluated, and as a result, a high accuracy of 99.1% was obtained. When this method is applied to the currently usesd system, it is concidered that the process of determining the position of the scintillation pixel will be simplified.

Measurement of Public Research Outcomes: A Technology Valuation Method

  • Park, Jung-Min;Lim, Seong-Il;Seol, Sung-Soo
    • Asian Journal of Innovation and Policy
    • /
    • v.6 no.2
    • /
    • pp.206-224
    • /
    • 2017
  • This article proposes a logic model for assessing the performance of the outcome of public research as a technology valuation method. It consists of two parts and eight steps. The first part is a scoring system and the second part is a validation process of the performance index derived from scoring by valuation method. The scoring in the first part generally requires a focus group method to find out the value drivers and make an evaluation table. The reason why we call it the technology valuation method is that the first part is derived from the simple evaluation of technology value using checklists for value drive. The second part is the regular technology valuation process. The model is designed for the measurement of unquantifiable outcome. Is knowledge or scientific outcome comparable to the measured outcome? If possible, how big is the unquantifiable outcome? This model is based on financial valuation techniques with clear or acceptable market data. Therefore, it cannot work solely for unquantifiable outcomes without comparable measurable outcomes, unlike economic valuation.

A Study on the In-Process Measurement of Metallic Surface Roughness in Cylindrical Grinding by Diode Laser (원통연삭가공시 반도체 레이저 빔을 이용한 금속표면거칠기의 인프로세스 측정)

  • 김희남;이주상
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.3
    • /
    • pp.30-41
    • /
    • 1995
  • This paper proposed a simple method for measuring surface roughness of ground surface. Utilizing non-contact in-process measuring system using the diode laser. The measurement system is consisted of a laser unit with a diode laser and a cylindrical lens, a detecting unit with polygon mirror and CCD array sensor, and a signal processing unit with a computer and device. During operation, this measuring system can provide information on surface roughness in the measuring distance with a single sampling and simultaniously monitor the state of the grind wheel. The experimental results, showed that the Increase of the feed rate and the dressing speed an caused increase in the surface roughness and when the surface roughness is 4Rmax-10Rmax, the cutting speed is 1653m/min-1665m/min, the table speed is 0.2n1/min -0.9m/min, the dressing speed is 0.2mm/rev~0.4mm/rev, the stylus method and the in-process method can be obtained the same results. Thus, under limited working conditions, using the proposed system, the surface roughness of the ground surface during cylindrical grinding can be obtained through the in-process measurement method using the diode laser.

  • PDF

Vibration Suppression Design on the Instrument Supporting Structure for the Optical Performance Measurement (대구경 반사경 광학성능 측정을 위한 간섭계 지지구조물의 진동저감 설계)

  • Kim, Hong-Bae;Lim, Jong-Min;Yang, Ho-Soon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.205-208
    • /
    • 2005
  • Fabrication of large scaled mirror for the telescope application is the most challenging technology in recent year. Sophisticate technologies and know-how in fabrication and measurement are required to overcome the technological obstacles. KRISS(Korea Research Institute for Standards and Science) is now developing a large scaled mirror fabrication facility and KARI(Korea Aerospace Research Institute) is supporting the development. High precision interferometric test is required during the grinding and polishing of mirror to identify the surface profile precisely. The required fabrication accuracy of the mirror surface profile is $\lambda$/50 ms($\sim$10 nm for visible wave length). Thus the measurement accuracy should be far less than 10 m. To get this requirement, it is necessary to provide vibration free environment for the interferometer system and mirror under test. Thus the vibration responses on the mirror supporting table due to external vibration should be minimized by using a special isolation system. And the responses on the top of the tower, which hold the interferometer during test, should be minimized simultaneously. In this paper, we propose the concept design of vibration suppression system for the KRISS mirror fabrication facility.

  • PDF

A vision-based system for dynamic displacement measurement of long-span bridges: algorithm and verification

  • Ye, X.W.;Ni, Y.Q.;Wai, T.T.;Wong, K.Y.;Zhang, X.M.;Xu, F.
    • Smart Structures and Systems
    • /
    • v.12 no.3_4
    • /
    • pp.363-379
    • /
    • 2013
  • Dynamic displacement of structures is an important index for in-service structural condition and behavior assessment, but accurate measurement of structural displacement for large-scale civil structures such as long-span bridges still remains as a challenging task. In this paper, a vision-based dynamic displacement measurement system with the use of digital image processing technology is developed, which is featured by its distinctive characteristics in non-contact, long-distance, and high-precision structural displacement measurement. The hardware of this system is mainly composed of a high-resolution industrial CCD (charge-coupled-device) digital camera and an extended-range zoom lens. Through continuously tracing and identifying a target on the structure, the structural displacement is derived through cross-correlation analysis between the predefined pattern and the captured digital images with the aid of a pattern matching algorithm. To validate the developed system, MTS tests of sinusoidal motions under different vibration frequencies and amplitudes and shaking table tests with different excitations (the El-Centro earthquake wave and a sinusoidal motion) are carried out. Additionally, in-situ verification experiments are performed to measure the mid-span vertical displacement of the suspension Tsing Ma Bridge in the operational condition and the cable-stayed Stonecutters Bridge during loading tests. The obtained results show that the developed system exhibits an excellent capability in real-time measurement of structural displacement and can serve as a good complement to the traditional sensors.