DOI QR코드

DOI QR Code

Comparison Between Performance of a Sound-Triggered Measurement and an Amplitude-Triggered Measurement in Shaking Table Tests

진동대를 이용한 모바일 진동 계측 기기의 사운드 트리거 계측과 진폭 트리거 계측 성능 비교

  • Mapungwana, S.T. (Dept. of Architecture, Seoul National University of Science and Technology) ;
  • Lee, Jong-Ho (Dept. of Architecture, Seoul National University of Science and Technology) ;
  • Yoon, Sung-Won (School of Architecture, Seoul National University of Science and Technology)
  • Received : 2019.01.15
  • Accepted : 2019.02.13
  • Published : 2019.03.15

Abstract

Micro-Electro-Mechanical Systems (MEMS) sensors have been widely used in Structural Health Monitoring due to their convenience and lower costs in comparison to conventional sensors. Triggered measurements are relevant in events such as earthquakes because unlike continuous measurements, they only record the structural response once an event happens. This is more cost effective and it makes the data more manageable because only the required measurements from the event are recorded. The most common method of triggering is amplitude triggering. However, lower input amplitudes (less than 0.1g) cannot be triggered by using this method. In this paper, sound triggering was introduced to allow triggered measurements for lower input amplitude values. The performance of the sound triggering and amplitude triggering were compared by a series of shaking-table tests. It was seen that sound-triggering method has a wider frequency (0.5~10Hz) and amplitude (0.01~1.0g) range of measurements. In addition, the sound triggering method performs better than the amplitude triggering method at lower amplitudes. The performance of the amplitude triggering, in terms of the triggering being simultaneous improves at higher input amplitudes.

Keywords

References

  1. Shrestha, A., Dang, J., & Wang, X., "Development of a smart-device-based vibration-measurement system: Effectiveness examination and application cases to existing structure", Structural Control Health Monitoring, Vol.25, No.3, 2018
  2. Feng, M., Fukuda, Y., Mizuta, M., & Ozer, E., "Citizen sensors for SHM: use of accelerometer data from smartphones", Sensors, Vol.15, No.2, pp.2980-2998, 2015 https://doi.org/10.3390/s150202980
  3. Mapungwana, S., Jung, Y. S., Lee, J. H., & Yoon, S. W., "Comparison Between Performance of a Wireless MEMS Sensor and an ICP Sensor in Shaking Table Tests", Journal of Korean Association for Spatial Structures, Vol.18, No.4, pp.49-59, 2018 https://doi.org/10.9712/KASS.2018.18.4.49
  4. Reilly, J., Dashti, S., Ervasti, M., Bray, J. D., Glaser, S. D., & Bayen, A. M., "Mobile Phones as Seismologic Sensors: Automating Data Extraction for the iShake System", IEEE Transactions on Automation Science and Engineering, Vol.10, No.2, pp.242-251, 2013 https://doi.org/10.1109/TASE.2013.2245121
  5. Vibration Version 2 [Software]. (2013). Diffraction Limited Design LLC. Retrieved from http://www.dld-llc.com
  6. iPad Mini 4 [Apparatus and software]. (2014). Apple Inc. Retrieved from https://web.archive.org/web/20141016183214/http://www.apple.com/ipad-mini-3/
  7. Bosch Sensortec [Apparatus]. (2018). Bosch. Retrieved from https://www.bosch-sensortec.com/bst/products/all_products/bma280
  8. APS 400 ELECTRO- SEIS [Apparatus]. (2018). APS Dynamics Inc. Retrieved from https://sensores-de-medida.es/catalogo/generador-de-vibraciones-electrodinamico-aps-400/
  9. APS 145 Amplifier [Apparatus]. (2018). APS Dynamics Inc. Retrieved from https://apsdynamics.com/en/products/power-amplifier.html
  10. Clover, J. (2014, September 26). iPhone 6 and 6 Plus Equipped With Two Accelerometers for Power Management, Improved User Experience [Web log post]. Retrieved from https://www.macrumors.com/2014/09/26/iphone-6-6-plus-two-accelerometers/