• Title/Summary/Keyword: measurement Noise

Search Result 3,227, Processing Time 0.03 seconds

The Performance Analysis of the DDFS to drive PLL (PLL을 구동하기 위한 DDFS의 성능분석)

  • 손종원;박창규;김수욱
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.8
    • /
    • pp.1283-1291
    • /
    • 2002
  • In this paper, the PLL driven by the DDFS is designed on the schematic using the Q-logic cell based library and is implemented using FPGA QL32 x16B. The measurement results of the frequency synthesizer switching speed were agreement with a register. The simulated results show that the clock delay was generated after eleven clock and if input is random, It has influence on output DA converter has to be very extensive. Therefore, the DDFS used noise shaper to drive PLL by regular interval for input state. Also the bandwidth of DA converter very extensive, the simulation shows that the variation of small input control word is better than the switching speed of PLL.

Calculation of Radiative Electric Field Intensity of Overhead Medium-Voltage Power lines for Power Line Communication (전력선통신을 위한 고압 배전선로의 방사전계강도 계산)

  • Chun Dong-wan;Park Young-jin;Kim Kwan-ho;Shin Chull-chai
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.12A
    • /
    • pp.1136-1146
    • /
    • 2005
  • In this paper, the radiative electric field intensity due to the communication signal and conductive noise is calculated in overhead medium voltage power lines for power line communication. The input impedance is calculated by means of 2 port equivalent model of medium voltage power line network and basic transmission line theory. And then, currents is calculated by calculated input impedance and finally, the emissive electric field is calculated. The input impedance appears like a standing wave form with a fixed cycle because high reflection at the input terminal due to the characteristic impedance of medium voltage power line is very large. A calculated current and radiative electric field also appears like this form. From the measurement results, the measured results are very similar to the calculated results.

The Electrical Characterization of the Quantized Hall Device with GaAs/AlGaAs heterojunction structure (GaAs/AlGaAs 이종접합된 양자흘 소자의 전기적 특성)

  • 유광민;류제천;한권수;서경철;임국형
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.334-337
    • /
    • 2002
  • The Quantum Hall Resistance(QHR) device which consists of GaAs/AlGaAs heterojunction structure is used for the realization of QHR Standard based on QHE. In order to characterize electrical contact resistances and dissipations of the device, it is slowly cooled down for eliminating thermal shock and unwanted noise. Then, the two properties are measured under 1.5 K and 5.15 T. Contact resistances are all within 1.2 Ω and longitudinal resistivities are all within 1 mΩ up to DC 90${\mu}$A. The results mean the device is operated well to realize the QHR Standard. To confirm it, the QHR Standard having the device is compared using a direct current comparator bridge with a 1 Ω resistance standard which the calibrated value is known from QHR standards maintained by other countries. The difference between them is agreed well within measurement uncertainty. It is thus considered that the properties of the device is estimated well and has good performance.

  • PDF

Design and Fabrication of RF evaluation board for 900MHz (900MHz대역 수신기용 RF 특성평가보드의 설계 및 제작)

  • 이규복;박현식
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.6 no.3
    • /
    • pp.1-7
    • /
    • 1999
  • A single RF transceiver evaluation board have been developed for the purpose of application to the 900MHz band transceiver contained RF-IC chip And environment test was evaluated. The RF-IC chipset includes LNA(Low Noise Amplifier), down-conversion mixer, AGC(Automatic Gain Controller), switched capacitor filter and down sampling mixer. The RF evaluation board for the testing of chipset contained various external matching circuits, filters such as RF/IF SAW(Surface Acoustic Wave) filter and duplexer and power supply circuits. With the range of 2.7~3.3V the operated chip revealed moderate power consumption of 42mA. The chip was well operated at the receiving frequency of 925~960MHz. Measurement result is similar to general RF receiving specification of the 900MHz digital mobile phone.

  • PDF

Performance Analysis of Pulse Positioning Using Adaptive Threshold Detector (ATD)

  • Chang, Jae Won;Lee, Sang Jeong
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.7 no.1
    • /
    • pp.25-35
    • /
    • 2018
  • This paper describes the measurement of pulse positioning (input time) to calculate a time of arrival (TOA) that takes from transmitting a signal from the target of multilateration (MLAT) system to receiving the signal at the receiver. In this regard, this paper analyzes performances of simple threshold method and level adjust system (LAS) method, which is one of the adaptive threshold detector (ATD) methods, among many methods to calculate pulse positioning of signal received at the receiver. To this end, Cramer-rao lower bound (CRLB) with regard to pulse positioning, which was measured when signals transmitted from a transponder mounted at the target were received at the receiver, was induced and then deviation sizes with regard to pulse positioning, which was measured with simple threshold and LAS methods through MATLAB simulations, were compared. Next, problems occurring according to a difference in amplitude of signals inputted to each receiver are described when pulse positioning is measured at multiple receivers located at a different distance from the target as is the case in the MLAT system. Furthermore, LAS method to resolve the problems is explained. Lastly, this study analyzes whether a pulse positioning error occurring due to the signal noise satisfies the requirement (6 nsec. or lower) recommended for the MLAT system when using these two methods.

2017 Total Solar Eclipse Expedition of KASI

  • Bong, Su-Chan;Choi, Seonghwan;Kim, Jihun;Park, Jongyeob;Jang, Bi-Ho;Park, Young-Deuk;Cho, Kyung-Suk;Cho, Kyuhyoun;Chae, Jongchul
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.67.2-67.2
    • /
    • 2017
  • Korea Astronomy and Space Science Institute (KASI) plans to develop a coronagraph to measure the coronal electron density, temperature, and speed using four different filters around 400 nm, where strong Fraunhofer lines from the photosphere are scattered by coronal electrons. During the total solar eclipse occurring on August 21 across USA, KASI will organize an expedition team to demonstrate the coronagraph measurement scheme and the instrumental technology. The observation site is in Jackson Hole, Wyoming, USA. We plan to build two coronagraphs without occulter to improve signal to noise ratio. In addition, images of white light corona, wide field background, and all sky are planned to be taken with DSLR cameras. We will present the preliminary results of the expedition.

  • PDF

Different Real Time PCR Approaches for the Fine Quantification of SNP's Alleles in DNA Pools: Assays Development, Characterization and Pre-validation

  • Mattarucchi, Elia;Marsoni, Milena;Binelli, Giorgio;Passi, Alberto;Lo Curto, Francesco;Pasquali, Francesco;Porta, Giovanni
    • BMB Reports
    • /
    • v.38 no.5
    • /
    • pp.555-562
    • /
    • 2005
  • Single nucleotide polymorphisms (SNPs) are becoming the most common type of markers used in genetic analysis. In the present report a SNP has been chosen to test the applicability of Real Time PCR to discriminate and quantify SNPs alleles on DNA pools. Amplification Refractory Mutation System (ARMS) and Mismatch Amplification Mutation Assay (MAMA) has been applied. Each assay has been pre-validated testing specificity and performances (linearity, PCR efficiency, interference limit, limit of detection, limit of quantification, precision and accuracy). Both the approaches achieve a precise and accurate estimation of the allele frequencies on pooled DNA samples in the range from 5% to 95% and don't require standard curves or calibrators. The lowest measurement that could be significantly distinguished from the background noise has been determined around the 1% for both the approaches, allowing to extend the range of quantifications from 1% to 99%. Furthermore applicability of Real Time PCR assays for general diagnostic purposes is discussed.

Position and Vibration Control of a Flexible Manipulator Using $\mu$-Synthesis ($\mu$-합성법에 의한 유연한 조작기의 위치 및 진동제어)

  • Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.10
    • /
    • pp.3186-3198
    • /
    • 1996
  • When a robot is to have contact with its enviornment, such as a medi-care robot, it would be advantageous for the robot to have a high compliance. For this reason, a robot having not only a flexible link but also an actuator with compliance, is desirable. This paper is concerned with the position and vibration control of 1 degree of freedom flexible robot using a pneumatic artificial muscle actuator. The dynamics of the manipulator assumed to be and Euler-Bernoulli beam are derived on the basis of the linear mathematical modle. Although this pneumatic artifical muscle actuator has many merits for the compliance robot, it is difficult to make an effective control scheme of this system because of ths nonlinearity and uncertainty on the dynamics of the actuator. By designing a controller using .mu.-synthesis, robust performance against measurement noise, various modeling uncertainties on the dynamics of the servo valve, actuator and mainpulator, is achieved. The effectiveness of the proposed control method is illustrated through simulations and experiments.

Improved Perfusion Contrast and Reliability in MR Perfusion Images Using A Novel Arterial Spin Labeling

  • Jahng, Geon-Ho;Xioaping Zhu;Gerald Matson;Weiner, Michael-W;Norbert Schuff
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.341-344
    • /
    • 2002
  • Neurodegenerative disorders, like Alzheimer's disease, are often accompanied by reduced brain perfusion (cerebral blood flow). Using the intrinsic magnetic properties of water, arterial spin labeling magnetic resonance imaging (ASLMRI) can map brain perfusion without injection of radioactive tracers or contrast agents. However, accuracy in measuring perfusion with ASL-MRI can be limited because of contributions to the signal from stationary spins and because of signal modulations due to transient magnetic field effects. The goal was to optimize ASL-MRI for perfusion measurements in the aging human brain, including brains with Alzheimer's disease. A new ASL-MRI sequence was designed and evaluated on phantom and humans. Image texture analysis was performed to test quantitatively improvements. Compared to other ASL-MRI methods, the newly designed sequence provided improved signal to noise ratio improved signal uniformity across slices, and thus, increased measurement reliability. This new ASL-MRI sequence should therefore provide improved measurements of regional changes of brain perfusion in normal aging and neurodegenerative disorders.

  • PDF

Thermal Deformation Error Analysis and Experiment of a Linear Motor (Linear Motor의 열변형 오차해석 및 실험)

  • 최우혁;민경석;오준모;최우천;홍대희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.286-289
    • /
    • 1997
  • In the design of structure the forces acting on the structure are important parameter for noise and vibration control. However, in the complex structure, the forces at the injection pomt on the structure cannot be measured directly. Thus it is necessary to find out indirect force evaluation method. In thls paper forces have been measured with in-situ vibration responses and system information. Three existing techniques of indirect force measurement, viz. direct inverse, principal component analysis and regularization have been compared. It has been shown that multi-vibration responses are essential for the precise estimation of the forces. To satisfy those cond~tions, Rotary compressor is adopted as test sample, because it is very difficult to measurc the injection forces from internal excitat~on to shell. It has also been obtained that relatively higher force IS transmitted through three welding paths to the compressor shell. It shows a good agreement between direct and indirect force evaluation wlth curvature shell and plate and is investigated the possibility of force evaluation of rotary compressor as a complex structure.

  • PDF