• Title/Summary/Keyword: mass error

Search Result 631, Processing Time 0.027 seconds

Parameter Sensitivity Analysis of Autonomous Robot Vehicle for Trajectory Error and Friction Force (자율 주행 반송차의 궤적 오차와 마찰력에 대한 매개 변수의 민감도 해석)

  • 김동규;박기환;김수현;곽윤근
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.2
    • /
    • pp.115-126
    • /
    • 1996
  • In order to obtain the principal design data for developing the Autonomous Robot Vehicle(ARV), Sensitivity analysis on the trajectory error and friction force with respect to the dynamic parameters is performed. In the straight motion, the trajectory error has been proved to be much affected by the mass variance of the ARV while the lateral friction force is much affected by the location of the mass center. In the curved motion, the effect of mass and moment of inertia is considered importantly. In addition, the lateral offset gives more effect than the geometric dimension of the ARV on the trajectory errors and friction force.

  • PDF

Application of Iterative Learning Control to 2-Mass Resonant System with Initial Position Error (위치 오차를 갖는 2관성 공진계에 대한 반복학습 제어의 적용에 관한 연구)

  • Lee, Hak-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.307-310
    • /
    • 2003
  • In this paper, an iterative learning control method is applied to suppress the vibration of a 2-mass system which has a flexible coupling between a load an a motor. More specifically, conditions for the load speed without vibration are derived based on the steady-state condition. And the desired motor position trajectory is synthesized based on the relation between the load and motor speed. Finally, a PD-type learning iterative control law is applied for the desired motor position trajectory. Since the learning law applied for the desired trajectory guarantees the perfect tracking performance, the resulting load speed shows no vibration. In order to handle the initial position error, the PD-type learning law is changed to PID-type and a weight function is added to suppress the residual vibration caused by the initial error. The simulation results show the effectiveness of the proposed learning method.

  • PDF

The study of Mass Reduction for mold through Finite Element Method (유한요소법을 이용한 금형의 경량화 방안에 관한 연구)

  • 주모담;조규종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.638-641
    • /
    • 1995
  • The model-technology has been conduced to a large quantity of automobile and electric products. However, many problems in mold-technology have been solved through trial and error of experts. So it has given rise to overdesign of mold and generated other problems in production line. In this paper we choosed the lower-mold of a cool chamber in refrigerator as the model of the study and mass reduced overdesigned mold. In mass reduction process, several cases in plane processing error were selected for the sample case through FEM analysis & simplicated theory analysis and each case was evaluated for mass reduction.

  • PDF

Errors in Isotope Dilution Caused by Matrix-induced Mass Bias Effect in Quadrupole Inductively Coupled Plasma-Mass Spectrometry

  • Pak, Yong-Nam
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.12
    • /
    • pp.3482-3488
    • /
    • 2014
  • Matrix-induced mass bias and its effect on the accuracy of isotope ratio measurements have been examined for a quadrupole-based inductively coupled plasma-mass spectrometer (Q ICP-MS). Matrix-induced mass bias effect was directly proportional to % mass difference, and its magnitude varied for element and nebulizer flow rate. For a given element and conditions in a day, the effect was consistent. The isotope ratio of Cd106/Cd114 under $200{\mu}g\;g^{-1}$ U matrix deviated from the natural value significantly by 3.5%. When Cd 111 and Cd114 were used for the quantification of Cd with isotope dilution (ID) method, the average of differences between the calculated and measured concentrations was -0.034% for samples without matrix ($0.076{\mu}g\;g^{-1}$ to $0.21{\mu}g\;g^{-1}$ for the period of 6 months). However, the error was as large as 1.5% for samples with $200{\mu}g\;g^{-1}$ U. The error in ID caused by matrix could be larger when larger mass difference isotopes are used.

Improvement of Mass Spectral Detection Performance by Pre-correction of Peak Position Error (피크위치오차 사전 보정을 통한 질량 스펙트럼 검출 성능 개선)

  • Lee, Young Hawk;Heo, Gyeongyong;Choi, Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.6
    • /
    • pp.666-674
    • /
    • 2019
  • In the mass spectrum of the mass spectrometer, the spectrum of the low peak adjacent to the spectrum having the high peak value is connected to each other and thus the separation is difficult. This inter-spectral overlap causes degradation of the mass spectral detection performance and resolution. In this paper, we propose a method to improve the mass spectrum detection performance and peak accuracy of residual gas analyzer. The type discrimination according to the characteristics of the ion signal block and the pre-correction for the peak position error can separate and detect the spectrum of the low peak connected to the adjacent spectra. To verify the performance of the proposed method, we compared the proposed method with the conventional method in simulations using actual ion signals obtained from the mass spectrometer under development.

Remedy for ill-posedness and mass conservation error of 1D incompressible two-fluid model with artificial viscosities

  • Byoung Jae Kim;Seung Wook Lee;Kyung Doo Kim
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4322-4328
    • /
    • 2022
  • The two-fluid model is widely used to describe two-phase flows in complex systems such as nuclear reactors. Although the two-phase flow was successfully simulated, the standard two-fluid model suffers from an ill-posed nature. There are several remedies for the ill-posedness of the one-dimensional (1D) two-fluid model; among those, artificial viscosity is the focus of this study. Some previous works added artificial diffusion terms to both mass and momentum equations to render the two-fluid model well-posed and demonstrated that this method provided a numerically converging model. However, they did not consider mass conservation, which is crucial for analyzing a closed reactor system. In fact, the total mass is not conserved in the previous models. This study improves the artificial viscosity model such that the 1D incompressible two-fluid model is well-posed, and the total mass is conserved. The water faucet and Kelvin-Helmholtz instability flows were simulated to test the effect of the proposed artificial viscosity model. The results indicate that the proposed artificial viscosity model effectively remedies the ill-posedness of the two-fluid model while maintaining a negligible total mass error.

Analysis and Comparison of Error Detection and Correction Codes for the Memory of STSAT-3 OBC and Mass Data Storage Unit (과학기술위성 3호 탑재 컴퓨터와 대용량 메모리에 적용될 오류 복구 코드의 비교 및 분석)

  • Kim, Byung-Jun;Seo, In-Ho;Kwak, Seong-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.417-422
    • /
    • 2010
  • When memory devices are exposed to space environments, they suffer various effects such as SEU(Single Event Upset). Memory systems for space applications are generally equipped with error detection and correction(EDAC) logics against SEUs. In this paper, several error detection and correction codes - RS(10,8) code, (7,4) Hamming code and (16,8) code - are analyzed and compared with each other. Each code is implemented using VHDL and its performances(encoding/decoding speed, required memory size) are compared. Also the failure probability equation of each EDAC code is derived, and the probability value is analyzed for various occurrence rates of SEUs which the STSAT-3 possibly suffers. Finally, the EDAC algorithm for STSAT-3 is determined based on the comparison results.

FINITE DIFFERENCE SCHEMES FOR A GENERALIZED NONLINEAR CALCIUM DIFFUSION EQUATION

  • Choo, S.M.
    • Journal of applied mathematics & informatics
    • /
    • v.27 no.5_6
    • /
    • pp.1247-1256
    • /
    • 2009
  • Finite difference schemes are considered for a nonlinear $Ca^{2+}$ diffusion equations with stationary and mobile buffers. The scheme inherits mass conservation as for the classical solution. Stability and $L^{\infty}$ error estimates of approximate solutions for the corresponding schemes are obtained. using the extended Lax-Richtmyer equivalence theorem.

  • PDF

자기동조 퍼지 알고리즘에 의한 탄성 로보트 Arm 선단의 위치제어

  • 양길태;안상도;이성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.04a
    • /
    • pp.213-217
    • /
    • 1993
  • This paper presents an end-point of 1-link flexible robot arm with a tip-mass by using self-turning fuzzy algorithm. The arm is mounted on a translational mechanism driven by a ballscrew, whose rotation is controlled by CD servomotor. Tip position is controlled so that it follows a desired position. A feedback signal is composed of both the tip-displacement error and change in error. This paper gives the experimental tip responses according to the variations of tip-mass and beam-length, and also showes the effects of reducing the residual vibrations occuring at the end-point.

A Study on the Performance of Thermal Mass Flowmeter (열량형 질량 유량계의 성능 평가)

  • Choi, Y.M.;Park, K.A.;Yoon, B.H.;Jang, S.;Choi, H.M.;Lee, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.595-600
    • /
    • 2001
  • Thermal mass flow meter(TMF) and thermal mass flow controller(MFC) were used to measure and to control the mass flow rate of gases. TMF and MFC were designed for specified working pressure and gas. For the case of different working pressure and gases, the flow rate measurement accuracy decreased dramatically. In this study, a TMF and MFC was tested with three different gases and pressure range from 0.2 MPa up to 1.0 MPa. Effect of specific heat causes to increase flow measurement error as much as ratio of specific heat compared with reference gas. Changing of pressure causes to increase flow rate measurement error about -0.2% as the working pressure decreased 0.1 MPa. Response time of MFC was below 3.12 s for the case of increasing of flow rate. But the response time was increased up to 6.92 s for the case of decreasing of flow rate. When the solenoid valve was fully closed, a initial delay time of output of MFC was increased up to 1.36 s.

  • PDF