• Title/Summary/Keyword: mSv

Search Result 571, Processing Time 0.027 seconds

Improvement in Bottom Detection for Hydroacoustic Assessment of Demersal Fish (저서어자원량의 음향추정에 있어서 해저검출 알고리즘에 관한 연구)

  • 황두진
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.3
    • /
    • pp.186-194
    • /
    • 2000
  • bottom as a reference basis, some theoretical elements which form bottom echoes during acoustic survey of demersal fish were considered. A stable bottom detection method based on maximum voltage difference, which was not influenced by variable levels and waveform transformation. The method has been shown to be effective using in-situ bottom echo waveforms and computer simulation data. A comparison between near-bottom SV profiles acquired in Funka Bay, Hokkaido, of Japan, the East China Sea and the Yellow Sea, of Korea, with the threshold method and maximum differential voltage method, shows that the SV obtained with the maximum differential voltage method is 4-6 dB higher than those with threshold method within 2m from the bottom.

  • PDF

Expression of the FLP recombinase of the 2 $\mu$m plasmid of yeast in the cultured cells of Bombyx mori using a transient expression vector (Yeast 2 $\mu$m 플라스미드 유래 FLP recombinase 유전자의 곤충 배양세포내 발현)

  • 강석우;윤은영
    • Journal of Sericultural and Entomological Science
    • /
    • v.39 no.1
    • /
    • pp.36-43
    • /
    • 1997
  • In order to express the FLP recombinase in B. mori cultured cell line, BmN-4, transient expression system using a heat shock protein gene (hsp70) promoter of Dorosophilla melnogaster was constructed. This vector was designated as pHsSV. Activity strength of the hsp70 promoter was compared with that of immediate early gene (IE-1) and polyhedrin gene of BmNPV employing the E. coli $\beta$-galactosidase gene as a reporter gene. The result showed that the pHs $\beta$-gal plasmid vector expressed the $\beta$-galactosidase at 2nd and 3rd day after the transfer of plasmid DNA into BmN-4 cells, which was similar to that of pIE1 $\beta$-gal vector, but different from that of a recombinant virus, vBm $\beta$-gal. For the construction of FLP recombinase transient expression vector, the FLP recombinase gene was cloned by polymerase chain reaction technique. To express the FLP recombinase, this gene was inserted into pHsSV plasmid vector, under the control of the hsp70 promotor, and tranfected in BmN-4 cells. The expressed FLP recombinase was estimated at 44kDa on a 12.5% SDS-PAGE.

  • PDF

Method for Determining Transportation Grade for HIC Containing Spent Resin Using Radioactivity Analysis (방사성페기물 핵종분석 결과를 사용한 폐수지의 운반물등급 분류 방법)

  • Kim, Tae-Wook;Choi, Ki-Seop;Kang, Ki-Doo;Ha, Jong-Hyun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.1
    • /
    • pp.11-15
    • /
    • 2008
  • In order to transport spent resin in a high integrated container made of high density polyethylene, a method for determining transportation grade by radioactivity analysis was developed. Ratios of radioisotopes in spent resin were derived from radioactivity analysis on spent resin. Associated curie-to-dose factors were determined to estimate radioisotope inventory from surface dose rates of spent resin. From the results, Activity limit of type A package was derived to be 1.19 TBq for HIC, and the corresponding surface dose rate was found to be 124.2 mSv/h.

  • PDF

The Implementation of Vital Sign Information Parsing Module using TMO(Time Triggered and Message Triggered Method) (TMO를 이용한 생체정보 수신모듈 구현)

  • Cho, Eui-Joo;Kim, Chun-Suk;Kim, Gwang-Gun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.4
    • /
    • pp.247-253
    • /
    • 2008
  • The TMO may contain two types of methods, time-triggered methods(also called the spontaneous methods of SpMs) which are clearly separated from the conventional service methods (SvMs). The SpM executions are triggered upon design time whereas the SvM executions are triggered by service request message from clients. In this paper, we describes the application environment as the patient monitor telemedicine system with TMO structure. Vital sign information web viewer systems is also the standard protocol for medical image and transfer. In order to embrace new technologies as telemedicine service, it is important to develope the standard protocol between different systems in the hospital, as well as the communication with external hospital systems.

  • PDF

Estimates of Genetic Correlations between Production and Semen Traits in Boar

  • Oh, S.H.;See, M.T.;Long, T.E.;Galvin, J.M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.2
    • /
    • pp.160-164
    • /
    • 2006
  • Currently, boars selected for commercial use as AI sires are evaluated on grow-finish performance and carcass characteristics. If AI sires were also evaluated and selected on semen production, it may be possible to reduce the number of boars required to service sows, thereby improving the productivity and profitability of the boar stud. The objective of this study was to estimate genetic correlations between production and semen traits in the boar: average daily gain (ADG), backfat thickness (BF) and muscle depth (MD) as production traits, and total sperm cells (TSC), total concentration (TC), volume collected (SV), number of extended doses (ND), and acceptance rate of ejaculates (AR) as semen traits. Semen collection records and performance data for 843 boars and two generations of pedigree data were provided by Smithfield Premium Genetics. Backfat thickness and MD were measured by real-time ultrasound. Genetic parameters were estimated from five four-trait and one five-trait animal models using MTDFREML. Average heritability estimates were 0.39 for ADG, 0.32 for BF, 0.15 for MD, and repeatability estimates were 0.38 for SV, 0.37 for TSC, 0.09 for TC, 0.39 for ND, and 0.16 for AR. Semen traits showed a strong negative genetic correlation with MD and positive genetic correlation with BF. Genetic correlations between semen traits and ADG were low. Therefore, current AI boar selection practices may be having a detrimental effect on semen production.

A Study on Overexposure Rate according to Overdensity in Chest X-ray Radiography(II) (흉부촬영에서 overdensity에 따른 overexposure rate를 아는 방법(II))

  • Kim, Jung-Min;Huo, Joon;Hayashi, Taro
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.13-19
    • /
    • 2000
  • We have presented with the "A study on overexposure rate according to over-density in chest X-ray radiography(I)" last year. In this report, We could calculate the entrance skin dose from chest X-ray film density the formula $I_0=Ix/e^{-{\mu}x}{\times}mG$, (mG is Bucky factor) was used to deliver the skin dose. At that time, There was two problems that the Bucky factor from maker was not equal to field experience and the field size influenced on the Attenuation Rate. The experiment of Bucky factor was done from film method and retried the Attenuation Rate of Acryle phantom according to Good & Poor geometry. As the results, The Bucky factor from maker higher than in this experiments $30{\sim}40%$. The Attenuation Rate in good geometric condition brings about a little alteration compare with poor geometric condition. In the field experiment, we could get the chest image with very low entrance skin radiation dose $29.3{\mu}Sv$, especially with air gap methode, the entrance skin dose was detected $10{\mu}Sv$.

  • PDF

Study of radiation exposure on human body using of Computed Tomography (전산화단층촬영 검사 시 인체에 미치는 방사선피폭선량 분석연구)

  • Seon, Jong-Ryoul;Yoo, Se-Jong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.193-198
    • /
    • 2015
  • This study analyzed the total number of 19,636 patients and radiation technologists, 11,433 of male and 8,203 of female by examined body parts, age, types of detectors, the using contrast enhancement and working condition of the technologists, regular staffs or rotation-duty staffs, based on the K-DOS program distributed by FDA with the DLP value of diagnostic evaluation. The result shows that the effective radiation dose was 0.7mSv~41.7mSv for each region and male patients had more radiation exposure than females. And the amount of exposure was also affected by the types and the method of detectors. Furthermore, the regular staffs took the role of helping the patient to get reduced amount of radiation exposure than rotation duty-staffs. Computed tomography (CT) use has increased dramatically over the past several decades. In this reason, to support the patients and the workers' health in the field, the hospitals should apply specialized regular working radiation technologist system and manufacturing companies of those CTs should develop low medical radiation exposure devices.

Radioactive effluents released from Korean nuclear power plants and the resulting radiation doses to members of the public

  • Kong, Tae Young;Kim, Siyoung;Lee, Youngju;Son, Jung Kwon;Maeng, Sung Jun
    • Nuclear Engineering and Technology
    • /
    • v.49 no.8
    • /
    • pp.1772-1777
    • /
    • 2017
  • Korean nuclear power plants (NPPs) periodically evaluate the radioactive gaseous and liquid effluents released from power reactors to protect the public from radiation exposure. This paper provides a comprehensive overview of the release of radioactive effluents from Korean NPPs and the effects on the annual radiation doses to the public. The amounts of radioactive effluents released to the environment and the resulting radiation doses to members of the public living around NPPs were analyzed for the years 2011-2015 using the Korea Hydro & Nuclear Power Co., Ltd's annual summary reports of the assessment of radiological impact on the environment. The results show that tritium was the primary contributor to the activity in both gaseous and liquid effluents. The averages of effective doses to the public were approximately on the order of $10^{-3}mSv$ or $10^{-2}mSv$. Therefore, even though Korean NPPs discharged some radioactive materials into the environment, all effluents were within the regulatory safety limits and the resulting doses were much less than the dose limits.

OPERATIONAL EXPERIENCE OF A TWO-DOSIMETER ALGORITHM FOR BETTER ESTIMATION OF EFFECTIVE DOSE AT KOREAN NUCLEAR POWER PLANTS

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.4
    • /
    • pp.165-169
    • /
    • 2009
  • Two dosimeters are provided to radiation workers participating in tasks where high radiation exposure is expected during maintenance at nuclear power plants. At Korean nuclear power plants, two dosimeters are currently provided for tasks where exposure rates exceed 1 mSv/hr, the difference of equivalent dose to specific parts of the body is more than 30% and an exposure of more than 2 mSv is expected in a single task. These conditions for the provisioning of two dosimeters are based on previous field test results, and it is recommended that the dosimeters be worn on the chest and back. It was also found that the workers felt it was more convenient when they wore two dosimeters on chest and back rather than on chest and head. After the application of previous field test results to practice, it was found that the calculated effective dose for workers during radiation work was lower than the maximum dose of chest or back dosimeter by approximately 10%-30%. This performance is regarded not only to meet the international guideline but also to provide convenience for workers during radiation work.

Entrapment of Plasmid DNA in Liposomes (리포솜을 이용한 플라스미드 DNA의 봉입)

  • Song, Mi-Hyang;Lee, Mann-Hyung;Yong, Chul-Soon;Oh, Doo-Man
    • Journal of Pharmaceutical Investigation
    • /
    • v.26 no.4
    • /
    • pp.291-297
    • /
    • 1996
  • Liposomes of $pSV-{\beta}-Galactosidase$ vector plasmid DNA with various lipid composition were prepared by the thin-film method. Size distribution, shape and the efficiency of plasmid DNA encapsulation were investigated. Effect of sonication time on the plasmid DNA entrapment in liposomes and stability at $4^{\circ}C$ were also examined. Sizes of neutral liposomes were about 100-200 nm and above $1\;{mu}m$, and those of cationic liposomes were about 400-600 nm and above $1\;{mu}m$. Shapes of liposomes entrapped plasmid DNA were spherical. Proper sonication time for better entrapment was below 15 minutes and stability at $4^{\circ}C$ was decreased rapidly after 1 day. Plasmid DNA entrapments of complex liposomes of various lipids were higher than those of liposomes made from one sort of lipid. Plasmid DNA entrapments of cationic liposomes were higher than those of neutral liposomes.

  • PDF