OPERATIONAL EXPERIENCE OF A TWO-DOSIMETER ALGORITHM FOR BETTER ESTIMATION OF EFFECTIVE DOSE AT KOREAN NUCLEAR POWER PLANTS

  • Published : 2009.12.30

Abstract

Two dosimeters are provided to radiation workers participating in tasks where high radiation exposure is expected during maintenance at nuclear power plants. At Korean nuclear power plants, two dosimeters are currently provided for tasks where exposure rates exceed 1 mSv/hr, the difference of equivalent dose to specific parts of the body is more than 30% and an exposure of more than 2 mSv is expected in a single task. These conditions for the provisioning of two dosimeters are based on previous field test results, and it is recommended that the dosimeters be worn on the chest and back. It was also found that the workers felt it was more convenient when they wore two dosimeters on chest and back rather than on chest and head. After the application of previous field test results to practice, it was found that the calculated effective dose for workers during radiation work was lower than the maximum dose of chest or back dosimeter by approximately 10%-30%. This performance is regarded not only to meet the international guideline but also to provide convenience for workers during radiation work.

Keywords

References

  1. Institute of Nuclear Power Operation (INPO). Guidelines for Radiological Protection at Nuclear Power Stations, INPO 91-014 Revision 01, 1995
  2. World Association of Nuclear Operations (WANO). Guidelines for Radiological Protection at Nuclear Power Plants, WANO GL 2004-01, 2004
  3. American National Standards Institute (ANSI). An American National Standard Criteria for Performing Multiple Dosimetry, Report No. HPS N13.41, 1997
  4. Personal Communication with Arif Khan and Dave Whillans of OPG. Summary of Changes to the Method of Assigning Dose from Multiple TLD Badges, 2002
  5. International Commission on Radiation Units and Measurements (ICRU). Measurements of Dose Equivalents from External Photon and Electron Radiation. ICRU Report 51, 1992
  6. Kim HG, Kong TY. A Study on the Application of Two-dosimeter Algorithm to Estimate the Effective Dose in an Inhomogeneous Radiation Field at Korean Nuclear Power Plants. Journal of Radiation Protection 2008 December;33(4):151-160
  7. Kim HG, Kong TY. Application of Estimating Effective Dose from External Radiation using Two Dosimeters during Maintenance Periods at KNPPs. Journal of Nuclear Science and Technology 2008 June;(5):151-154
  8. Korea Hydro and Nuclear Power Co. Ltd. Standard Procedure of Occupational Radiation Dose Assessment, 2006
  9. Korea Electric Power Research Institute (KEPRI). Application of Two-dosimeter Algorithm for Better Estimation of Effective Dose Equivalent to Inhomogeneous Radiation Field at NPPs. TM.105 NJ14.P2006.072, KEPRI, 2006
  10. Cha SC. Current Status of use of a Two-dosimeter. In: Proceedings of ALARA Symposium, 2008
  11. National Council on Radiation Protection and Measurements (NCRP). Use of Personal Monitors to Estimate Effective Dose Equivalent and Dose to Workers for External Exposure to Low-LET Radiation. NCRP Report No.122, Bethesda, 1995
  12. International Commission on Radiological Protection (ICRP). The 2007 Recommendations of the International Commission on Radiological Protection, ICRP Publication 103, 2007
  13. Korea Electric Power Research Institute (KEPRI). Development of Technology for Reducing Radiation Exposure in Primary System at Nuclear Power Plants. KRC-90N-J04, KEPRI, 1993
  14. Electric Power Research Institute (EPRI). Techniques for Controlling Radiation Exposure. Nuclear News (February), 43-47, 1993
  15. Korea Electric Power Corporation (KEPCO). Final Safety Analysis Report for the Yonggwang Nuclear Power Plant Unit No. 3 and 4, 2000
  16. Korea Electric Power Research Institute (KEPRI). Technical Seminar for Estimation of Effective Dose Equivalent using a Two-dosimeter by Dr. Chan Hyung Kim of Hanyang University, Technical Correspondence, KEPRI, 2004
  17. Yang MK. Experience of Advanced Two-dosimeter Procedure to Korean Nuclear Power Plants. In: Proceedings of 12th Dosimetry Workshop, 2008