• Title/Summary/Keyword: loss calculation

Search Result 759, Processing Time 0.022 seconds

Analysis of AC Losses in HTS Transformer with Double Pancake Windings (초전도 변압기 교류 손실 해석)

  • Kim Jong-Tae;Kim Woo-Seok;Kim Sung-Hoon;Choi Kyeong-Dal;Joo Hyeong-Gil;Hong Gye-Won;Han Jin-Ho;Lee Hee-Gyoun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.812-814
    • /
    • 2004
  • AC loss is one of the important parameters in (High Temperature Superconducting)HTS AC devices. Among the HTS AC power devices, the transformer is the essential part in the electrical power system. But unfortunately, the transformer is the worst HTS device concerning AC loss because of very large magnetization loss due to high magnetic field applied to the HTS wire. We calculated the magnetization losses in HTS pancake windings for transformer according to the operating temperature. Two kinds of arrangement of HTS pancake windings were adopted for calculation of AC losses of a shell type transformer, and the analysis results were presented and discussed.

  • PDF

Design and Efficiency Analysis 48V-12V Converter using Gate Driver Integrated GaN Module (게이트 드라이버가 집적된 GaN 모듈을 이용한 48V-12V 컨버터의 설계 및 효율 분석)

  • Kim, Jongwan;Choe, Jung-Muk;Alabdrabalnabi, Yousef;Lai, Jih-Sheng Jason
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.3
    • /
    • pp.201-206
    • /
    • 2019
  • This study presents the design and experimental result of a GaN-based DC-DC converter with an integrated gate driver. The GaN device is attractive to power electronic applications due to its superior device performance. However, the switching loss of a GaN-based power converter is susceptible to the common source inductance, and converter efficiency is severely degraded with a large loop inductance. The objective of this study is to achieve high-efficiency power conversion and the highest power density using a multiphase integrated half-bridge GaN solution with minimized loop inductance. Before designing the converter, several GaN and Si devices were compared and loss analysis was conducted. Moreover, the impact of common source inductance from layout parasitic inductance was carefully investigated. Experimental test was conducted in buck mode operation at 48 -12 V, and results showed a peak efficiency of 97.8%.

Ship Stability Calculation for Cause Analysis of No. 501 Oryong Sinking Accident (제501 오룡호 침몰사고 원인분석을 위한 선박 복원성 계산)

  • Lee, Jae-Seok;Chung, Young-Gu;Kim, Jee-Hun;Park, Ji-Hoon;Lee, Sang-Gab
    • Journal of Navigation and Port Research
    • /
    • v.42 no.6
    • /
    • pp.459-468
    • /
    • 2018
  • Deep-sea fishing vessel No. 501 Oryong was fully flooded through its openings and sank to the bottom of the Bering Sea. The tragic accident was attributed to rough sea weather after a fishing operation in the Bering Sea, and led to the death or loss of many crewmen. In this study, the ship stability calculation was carried out using KST-SHIP (ship calculation system of KST), considering the free surface effect and fish catch arrangement according to the progress of its sinking accident, and stability after flooding was analyzed. The calculation results obtained using KST-SHIP were verified by comparing them to intact stability calculation sheet of the accident ship under the full load departure condition, and intact stability according to displacement from the departure of accident ship up to the moment of the accident was calculated and analyzed. The stability after flooding was also calculated and analyzed according to the progress during its sinking accident.

Effects of Casein and Protein-free Diets on Endogenous Amino Acid Losses in Pigs

  • Zhang, Yongcheng;Li, Defa;Fan, Shijun;Piao, Xiangshu;Wang, Jitan;Han, In K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.11
    • /
    • pp.1634-1638
    • /
    • 2002
  • Quantification of endogenous amino acid loss at the terminal ileum is an essential means for calculation of the true amino acid digestibility of a feedstuff. Since nitrogen appeared in the determined diet or not could shift the results very much, also, none of digestibility markers could be recovered with 100% rate at the terminal ileum, the objectives of the present study were: (1) to determine endogenous amino acid losses when fed either a casein diet or a protein-free diet and (2) to examine the reliability of chromic oxide or acid insoluble ash in the protein-free diet. Six ileal-cannulated pigs ($65{\pm}1.85 kg$ BW) with a simple T-cannula in the terminal ileum were used in a replicated $3{\times}3$ Latin square designed trial, after allowed a 14 d recuperation period. Each test period ran for 12 days comprised of a 10 d adjustment period and a 2 d collection period. The endogenous AA losses of His, Ile, Lys, Cys, Thr, Val, Trp, Asp, Glu, and Ser from pigs fed the casein diet were significantly higher than those of the protein-free diet (p<0.05). No significant difference was found in the amount of endogenous amino acid loss when determined with the different markers in the protein-free diet (p>0.05). These data suggest that endogenous amino acid loss could be underestimated when a protein-free diet is used. A direct effect of dietary peptides on the endogenous amino acid loss was found when the casein diet was fed. Our results also indicate that acid insoluble ash can be used as an inert marker as an alternative to chromic oxide when measuring endogenous amino acid loss.

A Study on the Optimal Design of LLC Resonant Half-bridge dc-dc Converter Using a Steady-state Model with Internal Loss Resistors (내부 손실 저항이 있는 정상상태 모델을 이용한 LLC 공진형 하프 브리지 dc-dc컨버터의 최적 설계에 관한 연구)

  • Yoo, Jeong Sang;Ahn, Tae Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.3
    • /
    • pp.80-86
    • /
    • 2022
  • In this paper, the optimal design and circuit simulation verification results of an LLC resonant half-bridge dc-dc converter using a steady-state model with internal loss resistance are reported. Above all, the input/output voltage gain and frequency characteristic equations in the steady-state were derived by reflecting the internal loss resistance in the equivalent circuit. Based on the results, an LLC resonant half-bridge dc-dc converter with an input voltage of 360-420V, an output voltage of 54V, and a maximum power of 3kW was designed, and to verify the design, the PSIM circuit simulation was executed to compare and analyze the result. In particular, the operating range of the converter could be drawn from the frequency characteristic graph of the voltage gain, and when the converter was operated under light and maximum load conditions, it was confirmed that similar results were obtained by comparing simulation results and calculation results in the switching frequency characteristic graph. In addition, the change of the switching frequency with respect to the load current at each input voltage was compared with the calculated value and the simulation result. As a result, it was possible to confirm the usefulness of the analysis result reflecting the internal loss resistance proposed in this paper and the process of the optimal design.

Automatic Algorithms of Rebar Quantity Take-Off of Green Frame by Composite Precast Concrete Members (합성 PC부재에 의한 그린 프레임의 철근물량 산출 자동화 알고리즘)

  • Lee, Sung-Ho;Kim, Seon-Hyung;Lee, Goon-Jae;Kim, Sun-Kuk;Joo, Jin-Kyu
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.1
    • /
    • pp.118-128
    • /
    • 2012
  • As the bearing wall structure, which has been widely applied to domestic apartment buildings since the 1980s, cause many problems during remodeling of buildings, the government encourages constructors to adopt flat plate or rahmen structure through legal incentives. In line with such a trend, the green frame, an eco-friendly rahmen structure that has removed the shortcomings of previous structures, was developed to enhance structural safety, constructability, and eco-friendliness. The construction of green frame can reduce the labor cost and facilitate the composition of iron bars to reduce rebar loss through calculating the quality and establishing the bar bending schedule automatically on the precast concrete member data collected over the design phase. Therefore, the purpose of this study is to develop the algorithm to automate the calculation of iron bar volume for the green frame designed on composite precast concrete members. Automated algorithm to calculate concrete structural design information and design information. Practices through the application site should prove efficacy. The database established by the developed algorithm will automate the establishment of iron bar processing map and bar cutting list and the calculation of optimal composition and order volume to minimize the rebar loss. This will also reduce the expenses on management staff and overall construction cost through the minimization of rebar loss.

Comparative Analysis by Soil Loss and Sediment Yield Analysis Calculation Method of River using RUSLE and GRID (RUSLE와 GRID를 이용한 하천의 토양유실량 및 유사유출량 산정방법별 비교분석)

  • Park, Eui-Jung;Kim, Chul
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.10 no.2
    • /
    • pp.112-121
    • /
    • 2007
  • In occasion of soil loss happened in a basin, soil in the near of a stream may flow into the stream easily, but in case that soil is far away from the stream, sediment yield transferred to rivers by rainfall diminishes. To forecast sediment yield of a stream is an essential item for management of basins and streams. Therefore, sediment yield of soil loss produced from a basin is needed to be calculated as accurate as possible. Purpose of the present research is to calculate soil erosion amount in a basin and to forecast sediment yield flowed into a stream by rainfall and analyze sediment yield in the stream. There are various methods that analyze sediment yield of rivers. In the present study, the soil erosion amount was calculated using Revised Universal Soil Loss Equation(RUSLE) and GRID, and sediment yield was calculated using sediment delivery ratio and empirical methods. DEM data, slope of basin, soil map and landuse constructed by GIS were used for input data of RUSLE. The upstream area of the Yeongsan river basin in Gwangju metropolitan city was selected for the study area. Three methods according to the calculation of LS factor were applied to estimate the soil erosion amount. Two sediment delivery ratio methods for the respective methods were applied and, correspondingly, six occasions in sediment yield were calculated. In addition, the above results were compared by relative amount with estimation by the empirical method of Ministry of Construction & Transportation. Sediment yield calculated in the present study may be utilized for the plan, design and management of dams and channels, and evaluation of disaster impact.

  • PDF

Signal Transmission Properties Improvement of Serial Advanced Technology Attachment Connector Using Analysis of Differential Impedance (차동 임피던스 분석을 사용한 SATA 커넥터의 신호 전달 특성 개선)

  • Yang, Jeong-Kyu;Kim, Moonjung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.47-53
    • /
    • 2013
  • In this work, signal transmission properties of SATA connector have been improved using its differential impedance calculation and its design revision to closer impedance matching. Using 3 dimensional electromagnetic field simulator, the differential mode S-parameter was calculated to investigate its signal fidelity. The differential impedance is calculated from the equation of the odd mode impedance with inductance, capacitance, mutual inductance, and mutual capacitance. The differential impedance of SATA connector was calculated to be $107.3{\Omega}$ and did not meet the design specification with $100{\Omega}{\pm}5%$. In order to achieve its impedance range and improve its signal transmission properties, SATA connector's design has been revised with two different directions and analyzed through the calculation of differential impedance, differential reflection loss, and differential insertion loss.

Numerical Calculation for Input Impedance of a Conductor Located in the Loss Media (손실 매질에 위치한 도체의 입력임피던스 수치계산)

  • Ahn, Chang-Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.3
    • /
    • pp.230-236
    • /
    • 2013
  • This paper presents the numerical calculation for input impedance of a conductor located in the loss media by using the program with MATLAB. The input impedances of the conductor were numerically calculated with the moment of method. To increase an accuracy of results, the Galerkin's method which both the basic function and the weight function are the triangle function was applied. And by applying the modified image method, image sources of the conductor located in air were considered. According to the comparison between the current distributions at the conductor which were calculated with the MATLAB program and the NEC program, the reliability of the self-made program with MATLAB was obtained. In case of the conductor located in soil, which length are 1 m and 2 m, the input impedance were simulated as a function of both a conductivity and a frequency. Finally, input impedances and phases of the conductor located in soil were measured, and those results were compared with simulated results which calculated under the same conditions.

INTEGRAL BEHAVIOR OF THE ATLAS FACILITY FOR A 3-INCH SMALL BREAK LOSS OF COOLANT ACCIDENT

  • Choi, Ki-Yong;Park, Hyun-Sik;Cho, Seok;Euh, Dong-Jin;Kim, Yeon-Sik;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.199-212
    • /
    • 2008
  • A small-break loss of coolant accident (SB-LOCA) test with a break size equivalent to a 3-inch cold leg break of the APR1400 was carried out as the first transient integral effect test using the ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation). This was the first integral effect test to investigate the integral performance of the test facility and to verify its simulation capability for one of the design-basis accidents. Reasonably good thermal hydraulic data was obtained so that an integral performance of the fluid sub-systems was identified and control performance of the ATLAS was confirmed under real thermal hydraulic conditions. Based on the measured data, a post-test calculation was carried out using the best-estimate thermal hydraulic safety analysis code, MARS 3.1, and the similarity between the expected and actual data was investigated. On the whole, the post-test calculation reasonably predicts the major thermal hydraulic parameters measured during the SB-LOCA test. The obtained data will be used to enhance the simulation capability of the ATLAS and to improve an input model of the ATLAS for simulation of other target scenarios.