• Title/Summary/Keyword: long period structure

Search Result 474, Processing Time 0.025 seconds

Estimation of Design Wave Height for the Waters around the Korean Peninsula

  • Lee, Dong-Young;Jun, Ki-Cheon
    • Ocean Science Journal
    • /
    • v.41 no.4
    • /
    • pp.245-254
    • /
    • 2006
  • Long term wave climate of both extreme wave and operational wave height is essential for planning and designing coastal structures. Since the field wave data for the waters around Korean peninsula is not enough to provide reliable wave statistics, the wave climate information has been generated by means of long-term wave hindcasting using available meteorological data. Basic data base of hindcasted wave parameters such as significant wave height, peak period and direction has been established continuously for the period of 25 years starting from 1979 and for major 106 typhoons for the past 53 years since 1951 for each grid point of the North East Asia Regional Seas with grid size of 18 km. Wind field reanalyzed by European Center for Midrange Weather Forecasts (ECMWF) was used for the simulation of waves for the extra-tropical storms, while wind field calculated by typhoon wind model with typhoon parameters carefully analyzed using most of the available data was used for the simulation of typhoon waves. Design wave heights for the return period of 10, 20, 30, 50 and 100 years for 16 directions at each grid point have been estimated by means of extreme wave analysis using the wave simulation data. As in conventional methodsi of design criteria estimation, it is assumed that the climate is stationary and the statistics and extreme analysis using the long-term hindcasting data are used in the statistical prediction for the future. The method of extreme statistical analysis in handling the extreme vents like typhoon Maemi in 2003 was evaluated for more stable results of design wave height estimation for the return periods of 30-50 years for the cost effective construction of coastal structures.

Factors Affecting the Financial Structure of Hospitals in Korea (병원의 재무구조에 영향을 미치는 요인)

  • 최만규;문옥륜;황인경
    • Health Policy and Management
    • /
    • v.12 no.2
    • /
    • pp.43-75
    • /
    • 2002
  • This study focuses on the factors that make the financial structure of hospitals in Korea different, and on recommended courses of action that could be very helpful to hospitals in maintaining a sound financial structure. Data used in this study were collected from 132 hospitals with complete general data of present conditions as well as financial statements. They were chosen from the 174 hospitals that passed the standardization audit undertaken by the Korean Hospital Association from 1996 to 2000 for the purpose of accrediting training hospitals. The dependent variable in this study is financial structure. It consists of liabilities as against total assets (total liabilities to total assets, short-term liabilities to total assets, long-term liabilities to total assets, short-term borrowings to total assets, long-term borrowings to total assets). The independent variables are ownership type, hospital type, location, whether or not a representative is a director of the hospital, the possibility of changing a hospital director, bed size, period of establishment, asset structure, profitability, growth, tax shields, business risk, competition. The factors that appear to have the strongest impact on the liabilities to total assets of all the hospitals sampled are ownership type, hospital type, profitability, tax shields, and business risk. It was found that not-for-profit private hospitals and for-profit private hospitals have more liabilities than public hospitals, and tertiary medical institutions have less liabilities than the secondary general hospitals. Moreover, hospitals earning more at the expense of high business risk have a distinct tendency to lower liabilities. Concerning the current ratio, it was found that factors such as ownership type, hospital type, period of establishment, asset structure, and business risk are the more significant variables. The current ratio of public hospitals is higher than that of both not-for-profit private hospitals and for-profit private hospitals, and the current ratio of tertiary medical institutions is higher than that of general hospitals. As business risk is higher in hospitals compared to other businesses, the current ratio becomes higher; this is because it is assumed that for fear of bankruptcy, hospitals lessen liabilities to total assets. On the other hand, as hospitals become older, the fixed assets to total assets become lower. It is remarkable that in hospitals, the factors affecting liabilities to total assets have an opposite regression coefficient sign against factors affecting current ratio. It brings out the same results borne out by the old financial theories and researches, in which a lot of the liabilities of hospitals are considered as the cause of worsening liquidity. Therefore, it is very important for hospitals to maintain a sound financial structure in order to survive using the rational acquisition and maintenance of capital.

A Study on the Corrosion Mechanism by the Moisture on the Surface Layer of the Alloys Coated Steel Sheet (합금도금강판의 수적에 의한 표면층의 부식기구에 관한 연구)

  • Kim, Y.H.;Kim, S.K.;Jeon, E.C.
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.1 no.1
    • /
    • pp.71-78
    • /
    • 2002
  • Since the early 1980's the use of zinc-aluminum alloy-coated steel sheet(Galvalume) for vehicular corrosion protection has increased drastically. It is consisting of 55%Al-43.4% Zn-1.6%Si. Galvalume has a good corrosion resistance, heat reflectivity and shiny appearance, which has a dendritic structure of alloy layer. It has a good corrosion resistance due to dendritic structure. But, this also has a weak point against moisture during long period of transportation as sheeted and or coiled without any relation of chromating on the surface of steel sheet or not because of high humidity and temperature. Here, We studied the corrosion mechanism by the moisture.

  • PDF

A study on the Aluminium Beam Methods for Building a Stone Finished Envelope (석재 외피 시공을 위한 알루미늄 빔 지지공법 연구)

  • Kim, Jang-Ook;Lee, Young-Lae;Hong, Seong-Wook;Doh, Sun-Boong;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.235-242
    • /
    • 2012
  • In recently constructed building, It has become fashionable again that the heavy external skin system such as a Stone Finished Envelope. There are Squared Steel Pipe Methods, C-Shaped Steel Pipe Methods, and Aluminum Beam Methods in the structure of a heavy external skin system. The Aluminum Beam Methods is often misunderstood as a Plane Truss Structure, but this method is not appropriate to be called to a truss structure but a beam methods. The Aluminum Beam Methods is the most Eco-friendly methods in terms of Quality assurance, Efficiency, Safety, Construction period, Durability, and Recyclability. And this Methods is also very appropriate in considering the point of Energy conservation, Waste reduction, Long-life architecture, Replacement parts, Environmental protection, Public efficiency, and Building demolition.

  • PDF

A Study on Dynamic Response Analysis of the Cable-Stayed Bridge Structure Subjected to Near Fault Ground Motions (근거리 지진에 의한 사장교의 동적응답해석에 관한 연구)

  • 한성호;권의성;신재철;방명석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.439-446
    • /
    • 2004
  • In this study, the characteristic of the Near Fault Ground Motion which was not considered at the seismic design in our country and how the Near Fault Ground Motion affects the cable-stayed bridge which have long period is analyzed through the dynamic response analysis. So, the object of this study is following that it makes the data which can be utilized as the seismic safety evaluation in case of the cable-stayed bridge taken the near fault in the future.

  • PDF

A Study on the Seismic Response of Arch Structures Using Artificial Earthquake Ground Motions (아치구조물의 모의지진파 입력에 따른 지진응답특성에 관한 연구)

  • Jung, Chan-Woo;Park, Sung-Moo;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.6
    • /
    • pp.59-66
    • /
    • 2008
  • Seismic safety is more important for large spatial structure such as theaters, stadiums, gymnasiums since these structure are public goods. It is, however, difficult to understand behavior taking place when large spatial structure which has variety of structural system and shape receives seismic load. On this study, the natural vibration mode of arch structure which is main structural element of the large spatial structure, is checked. And then, when the artificial earthquake ground motion is applied to arch structure, it is more affective by long period component than magnitude of design acceleration spectrum.

  • PDF

The Impact of Capital Structure on Firm Performance: Evidence from Vietnam

  • NGUYEN, Hieu Thanh;NGUYEN, Anh Huu
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.4
    • /
    • pp.97-105
    • /
    • 2020
  • This paper explores the impact of capital structure on firm performance in the context of Vietnam. The paper investigates the different effect of capital structure on firm performance in state-owned and non-state enterprises listed on the Vietnam stock market. The panel data of research sample includes 488 non-financial listed companies on the Vietnam stock market for a period of six years, from 2013 to 2018. The Generalized Least Square (GLS) is employed to address econometric issues and to improve the accuracy of the regression coefficients. In this research, firm performance is measured by return on equity (ROE), return on assets (ROA), and earnings per share (EPS). The ratios of short-term liabilities, long-term liabilities, and total liabilities to total assets are proxy for capital structure. Firm sizes, growth rate, liquidity, and ratio of fixed assets to total assets are control variables in the study. The empirical results show that capital structure has a statistically significant negative effect on the firm performance. The result also shows this effect is stronger in state-owned enterprises than non-state enterprises in Vietnam. These evidences provide a new insight to managers of both state-owned and non-state enterprises on how to improve the firm's performance with capital structure.

A Study on the Application of Vertical Drainage System for Resisting Uplift of Sub-structure (지하구조물 부력방지를 위한 연직배수시스템의 적용성 연구)

  • Chun, Byung-Sik;Yeoh, Yoo-Hyeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.2
    • /
    • pp.183-190
    • /
    • 2001
  • A sub-structure is uplift if the floating greater than dead load of a structure. When such occasion arise, a structure sustain damage. In general, the measures for floating prevention of structure are a permanent anchor method and a drainage method. The primary construction cost of a permanent anchor method is heavy. And a drainage method is needed maintenance management long term. At this point, the measures for floating prevention of a notion being requires the other days. Therefore, at this study a simple construction and a economic vertical drainage system was developed. The findings be used in the in-situ and gave careful consideration to an application. The result of examination, this system considering a characteristic of coefficient of permeability for the ground controls occurrence of floating despite the water level rise of the ground, which a period of construction get shorter compared with other methods, which understood that measures satisfactory in the financial aspect. Especially, A structure occurring effects of flatting under the course of construction made use of it. As the result of the effect of it was confirmed by construction.

  • PDF

Guidelines of Designing Lead Rubber Bearing for a Cable-Stayed Bridge In Control Seismic Response (사장교의 지진 응답 제어를 위한 납고무 받침의 설계 기준 제안)

  • 이성진;박규식;김춘호;이인원
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.10a
    • /
    • pp.509-516
    • /
    • 2003
  • In tile design of base isolation system for building and short-span bridge, shift of the natural period of the structure is main objective. But, most long-span bridges such as a cable-stayed bridges have a number of long-period modes due to their flexibility and small structural damping. thus the design concept of base isolation system for building and short-span brigde may be difficult to use directly to these structures. However, the effectiveness of LRB for cable-stayed bridges is indicated by Ali and Abdel-Ghaffar. In this study, the design procedure and guidelines of LRB for a seismically excited cable-stayed bridge are investigated. The design properties of LRB are chosen that the design index(DI) is minimized or little changed for variation of properties. This result show that the stiffer rubber and bigger lead core size are need to cable-stayed bridges. And the seismic performance of designed LRB is also investigated. The consequences show that the perforamnce of designed LRB is better than that of Naeim-Kelly mettled designning LRB for general building structures. Moreover, the design properties of LRB are researched to several diffrent dominant frequency of earthquake. The results present that the plastic and elastic stiffness of LRB are affected by the dominant frequency of earthquake.

  • PDF

Study on the correlation between long-term exposure tests and accelerated corrosion tests by the combined damage of salts (염해 및 복합열화에 의한 부식촉진시험과 장기폭로 시험의 상관성에 관한 연구)

  • Park, Sang Soon;Lee, Min Woo
    • Corrosion Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.214-223
    • /
    • 2014
  • Interest in the durability assessment and structural performance has increased according to an increase of concrete structures in salt damage environment recent years. Reliable way ensuring the most accelerated corrosion test is a method of performing the rebar corrosion monitoring as exposed directly to the marine test site exposure. However, long-term exposure test has a disadvantage because of a long period of time. Therefore, many studies on reinforced concrete in salt damage environments have been developed as alternatives to replace this. However, accelerated corrosion test is appropriate to evaluate the critical chlorine concentration in the short term, but only accelerated test method, is not easy to get correct answer. Accuracy of correlation acceleration test depends on the period of the degree of exposure environments. Therefore, in this study, depending on the concrete mix material, by the test was performed on the basis of the composite degradation of the salt damage, and investigate the difference of corrosion initiation time of the rebar, and indoor corrosion time of the structure, of the marine environment of the actual environments were inuestigated. The correlation coefficient was derived in the experiment. Long-term exposure test was actually conducted in consideration of the exposure conditions submerged zone, splash zone and tidal zone. The accelerated corrosion tests were carried out by immersion conditions, and by the combined deterioration due to the carbonation and accelerated corrosion due to wet and dry condition.