• 제목/요약/키워드: linac accelerator

Search Result 137, Processing Time 0.03 seconds

The HPRF system for PEFP 20MeV proton linac

  • Seol, K.T.;Kwon, H.J.;Song, Y.G.;Park, M.Y.;Cho, Y.S.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2004.10a
    • /
    • pp.683-684
    • /
    • 2004
  • The RF system for PEFP 20MeV proton linear accelerator is described. The RF system for 3MeV RFQ was already installed and operated to drive the RFQ. The klystron was tested up to 600kW itself and operated up to 350kW routinely. The HPRF dummy load was stabilized with the change of the coolant. Preparation of 20MeV DTL HPRF test has been completed. LCP and PLC system for klystron power supply was already prepared. Voltage fluctuation was measured during klystron test. Voltage control feedback loop seems to be re-adjusted.

  • PDF

The manufacturing review and performance study of Synchrotron Radiation (S.R) DIPOLE MAGNET (방사광가속기용 2극 전자석의 제작과 특성연구)

  • Kim, Bang-Kwang;Choi, Sung-Duk;Park, Sung-Tae
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.588-592
    • /
    • 1992
  • The electrons, which are accelerated to nearly light speed from LINAC(Linear Accelerator), put into Storage Ring. And this electrons circulate in an ultra high vacuum chamber and their orbit is controlled by the electromagnets such as DIPOLE, QUADRUPOLE, SEXTUPOLE & CORRECTION MAGNET. Among them, the dipole magnet is to bend the electron and to produce Synchrotron Radiation(S.R). This paper describes the key point during manufacturing of this magnet, and introduce the field measurement results of the HEECO's successful prototype.

  • PDF

KOMAC RFQ Vacuum System

  • Han, J.M.d;S.H.Jeong;Cho, Y.S.;Park, B.H.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.33-33
    • /
    • 1999
  • The design of a vacuum pumping system for the KOMAC (Korea Multipurpose Accelerator Complex) RFQ(Radio-Frequency Quadrupole) linac is described. [Fig] Resulted from the lost proton beam, gas streaming from the LEBT (Low Energy Beam Transport) and out-gassing from the surfaces of the RFQ cavity and vacuum plumbing, the total gas load will be on the order of 7.2$\times$10-4 Torr-liters/sec, consisting mainly of hydrogen. The system designed to pump on a continual basis with redundancy to ensure that the minimal operating vacuum level of 1.0$\times$10-6 Torr is maintained even under abnormal conditions. Details of the design, performance analysis and the preliminary test results of the cryogenic pumps are presented.

  • PDF

Spin-polarization and x-ray magnetic circular dichroism in GaAs

  • Zohar, S.;Ryan, P.J.;Kim, J.W.;Keavney, D.J.
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1182-1184
    • /
    • 2018
  • The combination of angular spin momentum with electronics is a promising successor to charge-based electronics. The conduction bands in GaAs may become spin-polarized via optical spin pumping, doping with magnetic ions, or induction of a moment with an external magnetic field. We investigated the spin populations in GaAs with x-ray magnetic circular dichroism for each of these three cases. We find strong anti-symmetric lineshapes at the Ga $L_3$ edge indicating conduction band spin splitting, with differences in line width and amplitude depending on the source of spin polarization.

Measurement of Energy Dependent Neutron Capture Cross Sections of $^{197}Au$ in Energy Region from 0.1 eV to 10 keV using a Lead Slowing-down Spectrometer

  • Yoon, Jung-Ran
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.4
    • /
    • pp.29-32
    • /
    • 2010
  • The neutron capture cross section of $^{197}Au$ has been measured relative to the $^{10}B(n,{\gamma})$ standard cross section by the neutron time-of-flight(TOF) method using a 46-MeV electron linear accelerator(linac) at the Research Reactor Institute, Kyoto University(KURRI). In order to experimentally prove the result obtained, the supplementary cross section measurement has been made from 0.1 eV to 10 keV using the Kyoto University Lead slowing-down spectrometer (KULS) coupling to the linac. The relative measurement by the TOF method has been normalized to the reference value(24.5 b) at 1 eV. The evaluated capture cross sections in JENDL/D-99 Dosimetry have been compared with the current measurements by the KULS experiments.

Dosimetric Comparison of 6 MV Flattening Filter Free and 6 MV Stereotactic Radiosurgery Beam Using 4 mm Conical Collimator for Trigeminal Neuralgia Radiosurgery

  • Mhatre, Vaibhav R;Chadha, Pranav;Kumar, Abhaya P;Talapatra, Kaustav
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.3
    • /
    • pp.107-113
    • /
    • 2018
  • Background: The purpose of our study was to compare the dosimetric advantages of Flattening filter free (FFF) beams for trigeminal neuralgia patients using 4 mm conical collimators over previously treated patients with 6 MV SRS beam. Materials and Methods: A retrospective study was conducted for 5 TN patients who had been previously treated at our institution using frame-based, LINAC-based stereotactic radiosurgery (SRS) on Novalis Tx using 6 MV SRS beam were replanned on 6X FFF beams on Edge Linear accelerator with same beam angles and dose constraints using 4 mm conical collimator. The total number of monitor units along with the beam on time was compared for both Edge and Novalis Tx by redelivering the plans in QA mode of LINAC to compare the delivery efficiency. Plan quality was evaluated by homogeneity index (HI) and Paddick gradient index (GI) for each plan. We also analyzed the doses to brainstem and organ at risks (OARs). Results and Discussion: A 28% beam-on time reduction was achieved using 6X FFF when compared with 6X SRS beam of Novalis Tx. A sharp dose fall off with gradient index value of $3.4{\pm}0.27$ for 4 mm Varian conical collimator while $4.17{\pm}0.20$ with BrainLab cone. Among the 5 patients treated with a 4 mm cone, average maximum brainstem dose was 10.24 Gy for Edge using 6X FFF and 14.28 Gy for Novalis Tx using 6X SRS beam. Conclusion: The use of FFF beams improves delivery efficiency and conical collimator reduces dose to OAR's for TN radiosurgery. Further investigation is warranted with larger sample patient data.

High-Dose-Rate Electron-Beam Dosimetry Using an Advanced Markus Chamber with Improved Ion-Recombination Corrections

  • Jeong, Dong Hyeok;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Jang, Kyoung Won
    • Progress in Medical Physics
    • /
    • v.31 no.4
    • /
    • pp.145-152
    • /
    • 2020
  • Purpose: In ionization-chamber dosimetry for high-dose-rate electron beams-above 20 mGy/pulse-the ion-recombination correction methods recommended by the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM) are not appropriate, because they overestimate the correction factor. In this study, we suggest a practical ion-recombination correction method, based on Boag's improved model, and apply it to reference dosimetry for electron beams of about 100 mGy/pulse generated from an electron linear accelerator (LINAC). Methods: This study employed a theoretical model of the ion-collection efficiency developed by Boag and physical parameters used by Laitano et al. We recalculated the ion-recombination correction factors using two-voltage analysis and obtained an empirical fitting formula to represent the results. Next, we compared the calculated correction factors with published results for the same calculation conditions. Additionally, we performed dosimetry for electron beams from a 6 MeV electron LINAC using an Advanced Markus® ionization chamber to determine the reference dose in water at the source-to-surface distance (SSD)=100 cm, using the correction factors obtained in this study. Results: The values of the correction factors obtained in this work are in good agreement with the published data. The measured dose-per-pulse for electron beams at the depth of maximum dose for SSD=100 cm was 115 mGy/pulse, with a standard uncertainty of 2.4%. In contrast, the ks values determined using the IAEA and AAPM methods are, respectively, 8.9% and 8.2% higher than our results. Conclusions: The new method based on Boag's improved model provides a practical method of determining the ion-recombination correction factors for high dose-per-pulse radiation beams up to about 120 mGy/pulse. This method can be applied to electron beams with even higher dose-per-pulse, subject to independent verification.

Treatment of Intracranial Meningioma with Linac Based Radiosurgery (뇌수막종에서 선형가속기를 이용한 방사선수술 효과)

  • Kay Chul Seung;Yoon Sei Chul;Chung Su Mi;Ryu Mi Ryung;Kim Yeon Sil;Suh Tae Suk;Choi Kyuho;Son Byung Chul;Kim Moon Chan
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.81-86
    • /
    • 2001
  • Prupose : To evaluate the role of linac based radiosurgery (RS) in the treatment of meningiomas, we retrospectively analyzed the results of clinical and follow up CT/MRI studies. Methods and Materials : From the 1988 July to 1998 April, twenty patients of meningioma had been treated with 6 MV linear accelerator based radiosurgery. Of the 20 patients, four $(20\%)$ were male and 16 $(80\%)$ were female. Mean age was 51 years old ($22\~78$ years old). Majority of intracranial location of tumor for RS were parasagittal and sphenoid wing area. RS was done for primary treatment in 6 $(30\%)$, postoperative residual lesions in 11 $(55\%)$ and regrowth after surgery in 3 $(15\%)$. Mean tumor volume was $5.72\;cm^3\;(0.78\~15.1\;cm^3)$ and secondary collimator size was 2.04 cm $(1\~3\;cm)$. The periphery of tumor margin was prescribed with the mean dose of 19.6 Gy $(9\~30\;Gy)$ which was $40\~90\%$ of the tumor center dose. The follow up duration ranged from 2.5 to 109 months (median 53 months). Annual CT/MRI scan was checked. Results : By the follow up imaging studies, the tumor volume was reduced in 5 cases $(25\%)$, arrested growth in 14 cases $(70\%)$, and increased size in 1 case $(15\%)$. Among these responsive and stable 19 patients by imaging studies, there showed loss of contrast enhancement after CT/MRI in four patients. In clinical response, nine $(45\%)$ patients were considered improved condition, 10 $(50\%)$ patients were stable and one $(5\%)$ was worsened to be operated. This partly resulted in necrosis after surgery. Conclusion : The overall control rate of meningiomas with linac based RS was $95\%$ by both imaging follow-up and clinical evaluation. With this results, linac based RS is considered safe and effective treatment method for meningioma.

  • PDF

Development of Monte Carlo Simulation Code for the Dose Calculation of the Stereotactic Radiosurgery (뇌 정위 방사선수술의 선량 계산을 위한 몬테카를로 시뮬레이션 코드 개발)

  • Kang, Jeongku;Lee, Dong Joon
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.303-308
    • /
    • 2012
  • The Geant4 based Monte Carlo code for the application of stereotactic radiosurgery was developed. The probability density function and cumulative density function to determine the incident photon energy were calculated from pre-calculated energy spectrum for the linac by multiplying the weighting factors corresponding to the energy bins. The messenger class to transfer the various MLC fields generated by the planning system was used. The rotation matrix of rotateX and rotateY were used for simulating gantry and table rotation respectively. We construct accelerator world and phantom world in the main world coordinate to rotate accelerator and phantom world independently. We used dicomHandler class object to convert from the dicom binary file to the text file which contains the matrix number, pixel size, pixel's HU, bit size, padding value and high bits order. We reconstruct this class object to work fine. We also reconstruct the PrimaryGeneratorAction class to speed up the calculation time. because of the huge calculation time we discard search process of the ThitsMap and used direct access method from the first to the last element to produce the result files.

Electron beam scattering device for FLASH preclinical studies with 6-MeV LINAC

  • Jeong, Dong Hyeok;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Lee, Sang Jin;Kim, Hee Chang;Lee, Kyohyun;Kim, Seung Heon;Lee, Dong Eun;Jang, Kyoung Won
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1289-1296
    • /
    • 2021
  • In this study, an electron-scattering device was fabricated to practically use the ultra-high dose rate electron beams for the FLASH preclinical research in Dongnam Institute of Radiological and Medical Sciences. The Dongnam Institute of Radiological and Medical Sciences has been involved in the investigation of linear accelerators for preclinical research and has recently implemented FLASH electron beams. To determine the geometry of the scattering device for the FLASH preclinical research with a 6-MeV linear accelerator, the Monte Carlo N-particle transport code was exploited. By employing the fabricated scattering device, the off-axis and depth dose distributions were measured with radiochromic films. The generated mean energy of electron beams via the scattering device was 4.3 MeV, and the symmetry and flatness of the off-axis dose distribution were 0.11% and 2.33%, respectively. Finally, the doses per pulse were obtained as a function of the source to surface distance (SSD); the measured dose per pulse varied from 4.0 to 0.2 Gy/pulse at an SSD range of 20-90 cm. At an SSD of 30 cm with a 100-Hz repetition rate, the dose rate was 180 Gy/s, which is sufficient for the preclinical FLASH studies.