• 제목/요약/키워드: lightning protection system

검색결과 134건 처리시간 0.024초

옥내배선 배치에 따른 서지 전파양상 (Propagation Aspect of Lightning Surge According to The Arrangement of Indoor wire)

  • 이석우;황규현;서호준;이동희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.658-661
    • /
    • 2004
  • Lightning surge damages of low voltage equipments in building are increasing due to increase in electrical and communication networks in the information-oriented society And electrical circuits with semiconductor are very weak against lightning surge. To achieve effective method of surge protection on low voltage lines, there are needs for the relationship between propagation aspects of lightning surge and arrangement of indoor wire. This paper describes the experimental study on the relationship between them. This result may be raw data for establishment of surge protection system.

  • PDF

뇌서지에 의한 과전압 현상에 대한 실험연구 (Experimental Study of Overvoltage Phenomena due to Lightning Surge)

  • 이석우;고연성;여동구;서호준;이동희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.80-82
    • /
    • 2005
  • Lightning surge damages of low voltage equipments in building are increasing due to increase in electrical and communication networks in the information-oriented society. And electrical circuits with semiconductor are very weak against lightning surge. To achieve effective method of surge protection on low voltage lines, there are needs for the relationship between propagation aspects of lightning surge and arrangement of indoor wire. This paper describes the experimental study on the relationship between them. This result may be raw data for establishment of surge protection system.

  • PDF

선화아연바리스터 기반의 1-포트 서지보호장치의 최적 설계 기법 (Optimal Design Method of 1-Port Surge Protective Device Based on Zinc Oxide Varistor)

  • 정태훈;김용성;박근보;이승일
    • 한국산학기술학회논문지
    • /
    • 제19권4호
    • /
    • pp.93-102
    • /
    • 2018
  • 본 논문은 뇌격전류에 따른 저압 배전계통의 전자식 전력량계 및 배전 패널의 통신설비와 전원장치를 보호할 목적으로 사용하는 서지보호장치(SPD)에 관한 것이다. 서지보호장치(SPD)는 접속방식에 따라 1-포트 서지보호장치(SPD)와 감결합 요소를 포함한 2-포트 서지보호장치(SPD)로 구분된다. 뇌격전류에 대한 내부 시스템의 보호는 협조된 서지 보호체계를 이루는 계통적인 접근이 필요하다. 이에 대응하기 위해 이론적인 검토를 통해 피뢰구역(LPZ) 정의에 대한 고찰 및 해석을 진행하였다. 뇌서지에 의한 뇌격전류는 상당히 크기 때문에 하나의 서지보호장치(SPD)로 방호하기에는 한계가 발생하며, 이를 해결하기 위해 다단의 종속적으로 서지보호장치(SPD)를 설치하게 된다. 본 논문에서는 전력계통에 있어 한전계통에 연계되는 Incoming side가 아닌 건물 내에 설치되는 분기형 배전패널 내부의 전자식 전력량계 및 각종 통신(제어)설비를 보호할 목적으로 한전계통이 연계되는 MOF 단에 설치되는 LPZ0에 해당하는 피뢰기(LA, SA)와 보호협조를 이루는 LPZ1과 LPZ2의 경계영역에 설치하는 저압 배전계통용 II등급 서지보호장치(SPD)에 대해 설계를 하였다. 또한 감결합 요소가 없고, 부하 전류를 흘릴 수 있는 직렬 접속 방식의 1-포트 서지보호장치(SPD)에 대한 최적의 설계 방안을 도출하고 실험을 통해 기존의 방식과 비교하여 성능 개선과 관련한 검증을 실시하였다.

Performance Evaluation of Early Streamer Emission Lightning Air Terminal

  • Choi, Sang-Won;Her, Yong
    • International Journal of Safety
    • /
    • 제5권2호
    • /
    • pp.18-23
    • /
    • 2006
  • Studies have claimed that ESE (Early Streamer Emission) air terminals offer a vastly increased zone of protection over that of traditional lightning rods (Franklin rods) by causing the emission of an upward streamer/leader: The upward streamer/leader will propagate towards the tip of the downward leader at an early stage in the attachment process.. This paper shows the results of a performance evaluation test of a particular type of the ESE air terminal (called "ElecHippo") with a simple rod tested at the Korea Electrotechnology Research Institute (KERI). The corona emission current of the ElecHippo made by Yong-Jin Enterprise Corp. has also been measured at the Occupational Safety & Health Research Institute (OSHRI). The results show that the ElecHippo meets the French standard of NFC 17-102-1995. The results also verify the ESE performance by measuring the ion emission current generated in the discharge electrode gap as a function of the capacitance and inductance of the equipped devices. Finally, we propose a new method for grounding the system to reduce the lightning damage by combining the ESE air terminal, the early discharge earth plate, the lightning strike recorder and the surge protection device.

ZCT틀 이용한 피뢰기 열화 감시 시스템 개발 (Development of Lightning Arrester Degradation Monitoring System Using ZCT)

  • 박정남;이용희;장수형;김필석;신양섭;김영근;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1626-1628
    • /
    • 2003
  • The lightning arrester is a very important overvoltage protection device in the electric power system. Therefore, the inspection of lightning arrester whether it keeps its performance or not properly has close related to verifying the safety confidence of the electric power system. But the development of the deterioration measuring method and on-line detecting system, is necessary to monitor the deterioration of the lightening arrestor. In this paper, we developed the lightning arrester degradation monitoring system. This system detected leakage current of lightning arrester by using the ZCT, and analyze the third harmonics ingredient of leakage current using DFT method in the Data Acquisition Unit(DAU). The analyzed current signal is transmit to the Human-Machine Interface(HMI), and HMI alarmed when accident are occurred and informed with the amplitude of leakage current to the operator.

  • PDF

일점접지방식을 이용한 전자교환기 방호의 실제 (Engineering Practice for ESS Protection by means of One Point Grounding System)

  • 김수형;서정욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.502-505
    • /
    • 1988
  • This paper is to demonstrate the effectiveness of one point grounding in support of ESS protection. One point grounding provides for the dispatching of excess energy for protection of switching equipment and personnel from lightning discharge hazards and for a natural sink for noise from atmospheric lightning and power transients. In most ESS installations there are a number of different items that must be maintained at a common ground potential for safety, fault protection or noise reduction. The items typically consist of power systems, heating and ventilating systems, distributing frames, repeating equipmets, switching equipments, etc. Grounding system of an ESS Office is most effective when all the ground points are connected to a single, common earth. The one point grounding prvides a common reference potential, keeping all the items of telecommunications facility free from the earth current and voltage hazards.

  • PDF

공동주택에서의 인하도선시스템과 접지시스템 설계에 대한 고찰 (Considerations in Down-conductor System and Earth-termination System Design of Apartments)

  • 이기홍;이재복;장석훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.54-58
    • /
    • 2006
  • 본 논문에서는 공동주택에 적합한 인하도선시스템과 접지시스템 설계를 위한 기본적 사항에 대하여 고찰하였다. 공동주택의 철근구조체는 전기적 연속성을 갖지만 철근들끼리의 결속선에 의한 접속은 전자기계력에 대한 내력이 부족하다. 따라서 전용의 인하도선을 설치하고 이들을 건물 양 측벽의 철근구조체와 본딩하여 낙뢰전류가 인하도선 및 철근구조체에 분산되어 흐르게 하는 인하도선시스템을 제시하였다. 한편 공동주택의 접지시스템은 건물기초접지극과 피뢰설비를 위한 환형 접지극으로 각각 구성하고 이들을 서로 본딩하는 접지시스템을 제시하였다. 또한 공동주택 각동의 건물기초접지극을 공동구의 철근구조체나 접지선을 이용하여 서로 연결함으로서 공동주택 단지에 거대한 총괄접지시스템을 구현하는 방안을 제시하였다. 하지만 이러한 피뢰시스템을 구축하기 위해서는 완벽한 본딩시스템의 구축이 전제되어야 한다.

  • PDF

저압 전원계통 접지방식별 뇌서지보호성능 (Protection ability for lightning surge according to the grounding system of low voltage power systems)

  • 이복희;이규선;최종혁;유양우;김동성;강성만;안창환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.343-346
    • /
    • 2009
  • The grounding system of low voltage power systems is TT grounding system in Korea. In order to follow the international standard, TN grounding system is adopted. However, the performance of grounding systems has not been evaluated. This paper deals with the experimental results of protection ability of grounding system when lightning surge invades to the neutral line of low voltage power system. As a result, the TT grounding system is most frail for the lightning surge and it does not protect the electrical devices. On the other hand, the TN grounding system perfectly protects the electrical equipment and prevents the electric shock for human through the equipotential bonding. In case of TN system with supplement grounding, it is very important to lower the supplement grounding resistance to protect the electrical equipment and electric shock for human.

  • PDF

피뢰기에 의한 지중배전계통의 써어지 보호 (Surge Protection of Underground Distribution Systems by Surge Arrester Application)

  • 이용한;정동학;정동원;임용혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.176-179
    • /
    • 1992
  • This paper presents results of typical sutdy on lightning overvoltages of underground distribution systems and discusses effective insulation coordination schemes. Typical lightning current and system parameters are used to analyze lightning overvoltage distribution on underground distribution systems by EMTP (Electro-Magnetic Transients Program).

  • PDF

전차선로에서의 뇌격에 의한 가공지선과 보안기의 차폐효과 (Effects of an Overhead Ground Wire and Surge Arrester in the Railway due to Lightning Strokes)

  • 임성정;김재철;창상훈;정용철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 춘계학술대회 논문집
    • /
    • pp.93-99
    • /
    • 2000
  • Using the EMTP(Electro Magnetic Transient Program) for the analysis of lightning direct voltage on the railway system, the shielding effects of overhead grounding wire on the railway were studied quantitatively. Installation of overhead ground wire and gap-type arrester such as s-horn Provides a 6.6㎸ HV distribution line with good protection effects. Even severe lightning induced voltage were create, 6.6㎸ HV lines can be withstand.

  • PDF