• Title/Summary/Keyword: leakage path

Search Result 121, Processing Time 0.022 seconds

An Analysis of Geophysical and Temperature Monitoring Data for Leakage Detection of Earth Dam (흙댐의 누수구역 판별을 위한 물리탐사와 온도 모니터링 자료의 해석)

  • Oh, Seok-Hoon;Suh, Baek-Soo;Kim, Joong-Ryul
    • Journal of the Korean earth science society
    • /
    • v.31 no.6
    • /
    • pp.563-572
    • /
    • 2010
  • Both multi-channel temperature monitoring and geophysical electric survey were performed together for an embankment to assess the leakage zone. Temperature variation according to space and time on the inner parts of engineering constructions (e.g.: dam and slope) can be basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation (e.g.: cracks and defects) could be generated by various factors. Seepage or leakage of water through the cracks or defects in old dams will directly cause temperature anomaly. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For that matter, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old earth fill dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body. Geophysical data by electrical method are also added to help interpret data.

Analog Predistortion High Power Amplifier Using Novel Low Memory Matching Topology

  • Kim, Jang-Heon;Woo, Young-Yun;Cha, Jeong-Hyeon;Hong, Sung-Chul;Kim, Il-Du;Moon, Jung-Hwan;Kim, Jung-Joon;Kim, Bum-Man
    • Journal of electromagnetic engineering and science
    • /
    • v.7 no.4
    • /
    • pp.147-153
    • /
    • 2007
  • This paper represents an analog predistortion linearizer for the high power amplifier with low memory effect. The high power amplifier is implemented using a 90-W peak envelope power(PEP) LDMOSFET at 2.14-GHz and an envelope short matching topology is applied at the active ports to minimize the memory effect. The analog predistortion circuit comprises the fundamental path and the cuber and quintic generating circuits, whose amplitudes and phases can be controlled independently. The predistortion circuit is tested for two-tone and wide-band code division multiple access(WCDMA) 4FA signals. For the WCDMA signal, the adjacent channel leakage ratios(ACLRs) at 5 MHz offset are improved by 12.4 dB at average output powers of 36 dBm and 42 dBm.

High-Isolation SPDT RF Switch Using Inductive Switching and Leakage Signal Cancellation

  • Ha, Byeong Wan;Cho, Choon Sik
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.411-414
    • /
    • 2014
  • A switch is one of the most useful circuits for controlling the path of signal transmission. It can be added to digital circuits to create a kind of gate-level device and it can also save information into memory. In RF subsystems, a switch is used in a different way than its general role in digital circuits. The most important characteristic to consider when designing an RF switch is keeping the isolation as high as possible while also keeping insertion loss as low as possible. For high isolation, we propose leakage signal cancellation and inductive switching for designing a singlepole double-throw (SPDT) RF switch. By using the proposed method, an isolation level of more than 23 dB can be achieved. Furthermore, the heterojunction bipolar transistor (HBT) process is used in the RF switch design to keep the insertion loss low. It is demonstrated that the proposed RF switch has an insertion loss of less than 2 dB. The RF switch operates from 1 to 8 GHz based on the $0.18-{\mu}m$ SiGe HBT process, taking up an area of $0.3mm^2$.

A dual-path high linear amplifier for carrier aggregation

  • Kang, Dong-Woo;Choi, Jang-Hong
    • ETRI Journal
    • /
    • v.42 no.5
    • /
    • pp.773-780
    • /
    • 2020
  • A 40 nm complementary metal oxide semiconductor carrier-aggregated drive amplifier with high linearity is presented for sub-GHz Internet of Things applications. The proposed drive amplifier consists of two high linear amplifiers, which are composed of five differential cascode cells. Carrier aggregation can be achieved by switching on both the driver amplifiers simultaneously and combining the two independent signals in the current mode. The common gate bias of the cascode cells is selected to maximize the output 1 dB compression point (P1dB) to support high-linear wideband applications, and is used for the local supply voltage of digital circuitry for gain control. The proposed circuit achieved an output P1dB of 10.7 dBm with over 22.8 dBm of output 3rd-order intercept point up to 0.9 GHz and demonstrated a 55 dBc adjacent channel leakage ratio (ACLR) for the 802.11af with -5 dBm channel power. To the best of our knowledge, this is the first demonstration of the wideband carrier-aggregated drive amplifier that achieves the highest ACLR performance.

Disc Displacement Control of the Emergency Shut-Down Valve for LNG Bunkering (LNG 벙커링용 비상차단 밸브 디스크 변위 제어에 관한 연구)

  • Yoon, Jin Ho;Park, Ju Yeon;Jang, Ji Seong
    • Journal of Drive and Control
    • /
    • v.18 no.4
    • /
    • pp.28-34
    • /
    • 2021
  • Among the currently available types of fuel, LNG emits a relatively small amount of nitrogen oxide and carbon dioxide when it burns in the engine. However, since LNG is a flammable material, leakage during bunkering can lead to accidents, such as fires. Therefore, it is necessary to install a remote operation emergency shut-down (ESD) valve to block the flow and leakage of LNG in an emergency situation that occurs during bunkering. The ESD valve uses a hydraulic driving device consisting of a hydraulic control valve and a hydraulic motor to control globe valve disc displacement, which regulates the flow path for LNG transfer. At this time, there are various nonlinearities in hydraulic driving devices; hence, it is necessary to design a controller with robust control performance against these uncertainties. In this study, modeling of the ESD valve was carried out, and a sliding mode controller to control the displacement of the globe valve disc was designed. As a result, it was confirmed that the designed control performance could be achieved by overcoming nonlinearity characteristics using the designed controller.

Numerical investigation of supercavity geometry and gas leakage behavior for the ventilated supercavities with the twin-vortex and the re-entrant jet modes

  • Xu, Haiyu;Luo, Kai;Dang, Jianjun;Li, Daijin;Huang, Chuang
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.628-640
    • /
    • 2021
  • To investigate the supercavity geometry and gas flow structure for the supercavities with two closure types under the different flow conditions, an inhomogeneous multiphase model with the SST turbulence model was established, and validated by experimental results. The results show that two distinct regions exist inside the supercavity, which include the downstream flow region along the gas-water interface and the reverse flow region. For the twin-vortex supercavity, the internal gas leaks from the supercavity boundary by two paths: the supercavity surface and the two-vortex tubes. Increasing Froude number leads to more internal gas stripped from the supercavity surface. Two types of gas loss exist for the re-entrant jet supercavity with high Froude number, one type is the steady process of gas loss, and the major gas-leaking path is the supercavity surface rather than supercavity closure region. The other type is the unsteady periodic ejection, and the gas cluster of periodic ejection is merely a small part of the gas stored inside the supercavity.

User-steered balloon: Application to Thigh Muscle Segmentation of Visible Human (사용자 조정 풍선 : Visible Human의 다리 근육 분할의 적용)

  • Lee, Jeong-Ho;Kim, Dong-Sung;Kang, Heung-Sik
    • Journal of KIISE:Software and Applications
    • /
    • v.27 no.3
    • /
    • pp.266-274
    • /
    • 2000
  • Medical image segmentation, which is essential in diagnosis and 3D reconstruction, is performed manually in most applications to produce accurate results. However, manual segmentation requires lots of time to segment, and is difficult even for the same operator to reproduce the same segmentation results for a region. To overcome such limitations, we propose a convenient and accurate semiautomatic segmentation method. The proposed method initially receives several control points of an ROI(Region of Interest Region) from a human operator, and then finds a boundary composed of a minimum cost path connecting the control points, which is the Live-wire method. Next, the boundary is modified to overcome limitations of the Live-wire, such as a zig-zag boundary and erosion of an ROI. Finally, the region is segmented by SRG(Seeded Region Growing), where the modified boundary acts as a blockage to prevent leakage. The proposed User-steered balloon method can overcome not only the limitations of the Live-wire but also the leakage problem of the SRG. Segmentation results of thigh muscles of the Visible Human are presented.

  • PDF

A New High-Efficiency CMOS Darlington-Pair Type Bridge Rectifier for Driving RFID Tag Chips (RFID 태그 칩 구동을 위한 새로운 고효율 CMOS 달링턴쌍형 브리지 정류기)

  • Park, Kwang-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1789-1796
    • /
    • 2012
  • In this paper, a new high-efficiency CMOS bridge rectifier for driving RFID tag chips is designed and analyzed. The input stage of the proposed rectifier is designed as a cascade structure connected with two NMOSs for reducing the gate capacitance by circuitry method, which is the main path of the leakage current that is increased when the operating frequency is increased. This gate capacitance reduction technique using the cascade input stage for reducing the gate leakage current is presented theoretically. The output characteristics of the proposed rectifier are derived analytically using its high frequency small-signal equivalent circuit. For the general load resistance of $50K{\Omega}$, the proposed rectifier shows better power conversion efficiencies of 28.9% for 915MHz UHF (for ISO 18000 -6) and 15.3% for 2.45GHz microwave (for ISO 18000-4) than those of 26.3% and 26.8% for 915MHz, and 13.2% and 12.6% for 2.45GHz of compared other two existing rectifiers. Therefore, the proposed rectifier may be used as a general purpose rectifier to drive tag chips for various RFID systems.

A USB DLP Scheme for Preventing Loss of Internal Confidential Files (내부 기밀파일 유출 방지를 위한 USB DLP 기법)

  • Shin, Gyu Jin;Jung, Gu Hyun;Yang, Dong Min;Lee, Bong Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.12
    • /
    • pp.2333-2340
    • /
    • 2017
  • Recently industry is suffering severe losses of important internal information, and most of the leaks result from the insiders. Thus, various technological counter measures are being studied in order to protect private organization information. In this paper, among various internal information leakage path protection mechanisms, we propose a technique for preventing files which are defined as confidential from being copied or moved through USB. The implemented confidential file loss prevention system is composed of both signature insert manager and confidential file detect manager. The signature insert manager allows a system administrator to insert a special pattern specifying a classified confidential file, while the confidential file detect manager protects confidential file leakage when a user attempts to move or copy a confidential file to the USB memory. This results would be contributed to reducing the damage caused by leakage of confidential files outside of the company via USB.

Applicability of CGS for Remediation and Reinforcement of Damaged Earth Dam Core (손상된 흙댐 코어의 보수.보강을 위한 CGS 공법의 적용성)

  • 천병식;최중근
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.325-334
    • /
    • 2003
  • It is very difficult to rehabilitate the damaged earth dam core to manage it stably against development of flow path and increase of leakage by hydraulic fracture. In this study, application of CGS (Compaction Grouting System) to damaged earth dam core was noticed by analyzing and comparing the results of the in-situ data and FEM. Results of in-situ data showed that according as progress of rehabilitation works tip pressures increased and volume of injection decreased, voids of damaged dam core were filled with materials similar to origin dam core. Rehabilitations caused turbidity and volume of leakage to decrease at the same water level. Also, results of FEM analysis indicated that permeability decreased by rehabilitation. Through this study, it is proved that CGS is able to decrease permeability coefficient, volume of leakage and turbidity on damaged earth dam core.