• Title/Summary/Keyword: k-$\omega$

Search Result 3,473, Processing Time 0.03 seconds

A Study on the Analysis of the Resistance Characteristics and Damage Patterns of Brass Fittings Type CSST (황동이음쇠형 금속플렉시블호스(CSST)의 저항 특성 및 소손 패턴 해석에 관한 연구)

  • Lee, Jang-Woo;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.67-73
    • /
    • 2016
  • This paper examined the structure, fire resistance of brass fittings type CSST employed in gas appliances and the reliability verification. Brass fittings of type CSST consisted of cladding, tubing, nut, clamp ring, socket, and ball valve. The applicable JIA standard regulates the maximum working pressure to be 4.2 kPa, which is the highest pressure of the relevant standards and the KS D 3625 stipulates the maximum pressure to be 3.24 kPa. With a normal product, the average resistance within the confidence interval was found to be $7.36m{\Omega}$. The average resistance within the confidence interval was $6.67m{\Omega}$ after the fire resistance tests. The analysis indicated that the AD was 1.584 and the standard deviation was 0.3972 with respect of a normal product. Compared to the normal product, however, the damaged product after the fire resistance test showed better features, such as an AD of 1.145 and a standard deviation of 0.2467. Moreover, the average resistance of the normal product was $7.359m{\Omega}$ and the standard deviation in histogram analysis was 0.3972. The average resistance of the damaged product after the fire resistance test in the histogram was $6.67m{\Omega}$ and the standard deviation was 0.2467.

THE HYPERBOLIC METRIC ON K-CONVEX REGIONS

  • Song, Tai-Sung
    • The Pure and Applied Mathematics
    • /
    • v.5 no.2
    • /
    • pp.87-93
    • /
    • 1998
  • Mejia and Minda proved that if a hyperbolic simply connected region $\Omega$ is k-convex, then (equation omitted), $z \in \Omega$. We show that this inequality actually characterizes k-convex regions.

  • PDF

Comparative Study on k-ε and k-ω Closures under the Condition of Turbulent Oscillatory Boundary Layer Flow at High Reynolds Number (높은 레이놀즈수를 가진 난류 진동 경계층에서의 k-ε과 k-ω 난류모형의 비교)

  • Son, Min-Woo;Lee, Guan-Hong;Lee, Kil-Seong;Lee, Du-Han
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.3
    • /
    • pp.189-198
    • /
    • 2011
  • The aim of this study is to compare k-$\varepsilon$ and k-$\omega$ closures under the condition of oscillatory layer flow at high Reynolds number. A one dimensional vertical model incorporated with flow momentum equations and turbulence models (k-$\varepsilon$ and k-$\omega$) is applied to the laboratory measurements in the turbulent oscillatory boundary layer. The numerical simulation reveals that both turbulence models calculate similar velocity profiles and turbulent kinetic energy (TKE). In addition, both deliver high accuracy under the condition of negligible spanwise pressure gradient. Therefore, it is recommended in this study to use k-$\varepsilon$ closure, of which numerical coefficients have been calibrated from many studies, for the cases of straight channel, estuary, and coastal environment where the spanwise pressure gradient is not significant.

The Application of Standard in According to Ground and Electrical Continuity Testing of Lightning Protection Equipment in Field (피뢰설비현장의 접지 및 전기적 연속성 시험에 따른 표준적용)

  • Song, Gil-Mok;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.583-588
    • /
    • 2014
  • In this study, there are examined to the grounding of lightning protection system and electrical continuity tests in the field. The standard for lightning protection system is different design or construction according to the characteristics of the structure. Ground is measured and compared at least four locations. According to the measured results in the field, the sampled values of the ground resistance are measured $5{\Omega}$ or less and the difference between each value is suitable as $0.2{\Omega}$ or less. The values of the electrical continuity test between ground and metal bodies are measured 3 groups such as isolated portion, the mechanical contacted portion, and the electrical continuity portion measuring $0.2{\Omega}$ or less. It is measured to be less than $0.2{\Omega}$ at all in metal bodies of underground. A metal body installed inside the structure is not isolated, but the resistance values are higher than $0.2{\Omega}$. Therefore, It must be carried out the structure having lightning protection system confirm the LPL(lightning protection level) and design the strategy.

Similarity analysis of a forced uniform flow impinging on a rotating disk in a vapor deposition process (증착공정에서의 회전원판 정체점유동에 대한 상사해석)

  • Song, Chang-Geol;Hwang, Jeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.3
    • /
    • pp.371-379
    • /
    • 1997
  • A theoretical study for a forced uniform flow impinging on a rotating disk, typically involved in Chemical Vapor Deposition(CVD) and Vapor-phase Axial Deposition(VAD) processes, has been carried out. A set of exact solutions for flow and temperature fields are developed by employing a similarity variable obtained from force balance on a control volume near the disk. The solutions depend on the rotating speed of the disk, .omega., and the forced flow speed toward the disk, a. For constant forced flow speed, the overall boundary layer thickness decreases when the rotating speed increases. Approximately 5%, 15%, and 30% decreases of the thickness are obtained for .omega./a = 2, 5, and 10, respectively, compared to the case of .omega./a = 0 (axisymmetric stagnation point flow). For constant rotating disk speed the boundary layer thickness immediately decreases as the forced flow speed increases, compared to the case of .omega./a .rarw. .inf. (induced flow near a rotating disk). Effects of .omega. and a on heat transfer coefficient are studied and explained with the boundary layer characteristics.

Coregulation of lux Genes and Riboflavin Genes in Bioluminescent Bacteria of Photobacterium phosphoreum

  • Sung, Nack-Do;Lee, ChanYong
    • Journal of Microbiology
    • /
    • v.42 no.3
    • /
    • pp.194-199
    • /
    • 2004
  • Investigation of the expression of the riboflavin (rib) genes, which are found immediately downstream of luxG in the lux operon in Photobacterium phosphoreum, provides more information relevant to the evolution of bioluminescence, as well as to the regulation of supply of flavin substrate for bacterial bioluminescence reactions. In order to answer the question of whether or not the transcriptions of lux and rib genes are integrated, a transcriptional termination assay was performed with P. phoxphoreum DNA, containing the possible stem-loop structures, located in the intergenic region of luxF and luxE ($\Omega$$\_$A/), of luxG and ribE ($\Omega$$\_$B/), and downstream of ribA ($\Omega$$\_$c/). The expression of the CAT (Chloram-phenicol Acetyl Transferase) reporter gene was remarkably decreased upon the insertion of the stem-loop structure ($\Omega$$\_$c/) into the strong lux promoter and the reporter gene. However, the insertion of the structure ($\Omega$$\_$B/) into the intergenic region of the lux and the rib genes caused no significant change in expression from the CAT gene. In addition, the single stranded DNA in the same region was protected by the P. phosphoreum mRNA from the Sl nuclease protection assay. These results suggest that lux genes and rib genes are part of the same operon in P. phosphoreum.

A Study on the Ignition Hazard of Flammable Mixtures by Radio-Frequency Spark (고주파 스파크에 의한 가연성 혼합가스의 점화위험성에 관한 연구)

  • Choi, Sang-Won;Lee, Gwan-Hyung;Moon, Jung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1913-1916
    • /
    • 1996
  • With a progress of electrical and electronic technology, radio-frequency circuits including high frequency components are widely applied to various industrial installations. Some of them are used in hazardous locations where explosive or flammable gases exist. As a result, ignition of such gases may be induced by a spark discharge when the radio frequency circuits are switched on or off. The purpose of this study is to investigate the ignition hazards of acetylene-air and ethylen-air mixtures experimentally based on the IEC 79-3 publication. In this experiment, we used a high frequency resistive circuit which consists of a co-axial cable, a $10{\Omega}$, $20{\Omega}$, $30{\Omega}$, $40{\Omega}$ or $50{\Omega}$ resistor and a power amplifier with frequency range up to almost 1 MHz. Experimental results show that the ignition of the acetylene-air and ethylen-air mixtures due to spark discharge depends primarily on the frequency of the power source in the resistive circuit: the minimum ignition voltage increases gradually with the increase of the frequency.

  • PDF

On Mimimal Sufficient Statistics

  • Nabeya, Seiji
    • Journal of the Korean Statistical Society
    • /
    • v.10
    • /
    • pp.83-90
    • /
    • 1981
  • Let (X, A) be a measurable space, i.e. X is a non-empty set and A is a $\sigma$-field of subsets of X. Let $\Omega$ be a parameter space and P be a family of probability measures $P_\theta, \theta \in \Omega$ defined on (X, A).

  • PDF

On Some Properties of Ordinal Space

  • Chil, Yoon Kyo
    • The Mathematical Education
    • /
    • v.20 no.1
    • /
    • pp.47-49
    • /
    • 1981
  • In this paper, we give several properties of ordinal spaces [0, $\Omega$] and [0, $\Omega$].

  • PDF