• Title/Summary/Keyword: internal shading

Search Result 29, Processing Time 0.028 seconds

Evaluation of Computational Fluid Dynamics for Analysis of Aerodynamics in Naturally Ventilated Multi-span Greenhouse

  • Lee, In Bok;Short, Ted H.;Sase, Sadanori;Lee, Seung Kee
    • Agricultural and Biosystems Engineering
    • /
    • v.1 no.2
    • /
    • pp.73-80
    • /
    • 2000
  • Aerodynamics in a naturally ventilated multi-span greenhouse with plants was analyzed numerically by the computational fluid dynamics (CFD) simulation. To investigate the potential application of CFD techniques to greenhouse design and analysis, the numerical results of the CFD model were compared with the results of a steady-state mass and energy balance numerical model. Assuming the results of the mass and energy balance model as the standard, reasonably good agreement was obtained between the natural ventilation rates computed by the CFD numerical model and the mass and energy balance model. The steady-state CFD model during a sunny day showed negative errors as high as 15% in the morning and comparable positive errors in the afternoon. Such errors assumed to be due to heat storage in the floor, benches, and greenhouse structure. For a west wind of 2.5 m s$^{-1}$ , the internal nonporous shading screens that opened to the east were predicted to have a 15.6% better air exchange rate than opened to the west. It was generally predicted that the presence of nonporous internal shading screens significantly reduced natural ventilation if the horizontal opening of the screen for each span was smaller that the effective roof vent opening.

  • PDF

Three Dimensional Shape Estimation by Shading Analysis of Endoscopic Image (음영분석에 의한 내시경 영상의 3차원 형체 추정에 관한 연구)

  • Lee, Tae-Su;Cha, Eun-Jong;Yun, Se-Jin
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.499-506
    • /
    • 1995
  • A new numerical method estimated three dimensional shape of the internal surface of the stomach by analyzing the shading data of endoscopic image. First analyzed was the inherent instrumentational characteristics of the endoscope system, followed by the analysis of the stomach surface properties, both of which affected the imaging properties. We employed these prior informations to implement the iterative algorithm of shading analysis based on Hom's variational approach. The present algorithm was validated by performing simulation on a $256{\times}320$ image data chosen from original $512{\times}512$ image of the stomach surface model. The best 3-dimensional estimation of the surface was achieved with the Lagrangian multiplier, of 0.3, when the algorithm best converged showing minimal estimation error.

  • PDF

Changes in Greenhouse Temperature and Solar Radiation by Fogging and Shading During Hydroponics in Summer Season (여름철 수경재배 시 포그 분무와 차광에 의한 하우스 내부 온도 및 광 환경 변화)

  • Lim, Mi Young;Jeong, Ho Jeong;Roh, Mi Young;Choi, Gyeong Lee;Kim, So Hui;Choi, Su Hyun
    • Journal of Bio-Environment Control
    • /
    • v.30 no.3
    • /
    • pp.230-236
    • /
    • 2021
  • Changes in greenhouse temperature and solar radiation due to fogging and shading were monitored during hydroponics in high temperature in summer season. Experiment 1 consists of four treatments, namely, Control, Shading, Fogging, and Fogging + Shading based on sunny days August. For Experiment 2, two melon cultivars of 'Dalgona' and 'Sopoong gaza' were cultivated in summer of 2020 using Fogging + Shading with the best result for temperature reduction effect from Experiment 1. As a result of Experiment 1, the effect of Fogging + Shading on temperature reduction was apparent where the inside was about 4℃ (as the lowest temperature) lower than the outside. Fogging + Shading showed the inside was 2-4℃ lower than the outside, and Fogging or Shading treatments had little difference, compared to the Control where the internal temperature of greenhouse was 3-4℃ higher than the external. For solar radiation changes between greenhouse inside and outside, the internal change was in a similar pattern between Fogging and Control, and between Shading and Fogging + Shading, respectively. In case of the Fogging treatment (similar with the Control) only the effect of solar radiation reduction as influenced by plastic greenhouse covering materials was examined. The Fogging + Shading had a very similar change in solar radiation to the Shading. Based on these results, Experiment 2 was conducted in summer of 2020 and resulted in a temperature reduction effect of about 3.9℃ according as the inside of air-conditioned greenhouse was kept 32.4℃ when the maximum temperature of the outside reached 36.3℃ in August during the cultivation period. In addition, the quality of melon fruit was good (1.3-1.5 kg of fruit weight, 12.6-13.3 of soluble solids content. In the case of using Fogging + Shading cooling treatment, it can bring about the effect of reducing the temperature during the high temperature in summer, and normal growth of melon and fruit harvesting were possible.

An Experimental Study on the Reduction Effects of Shading Devices on Sky Radiant Cooling in Winter (차양장치의 겨울철 천공복사 냉각 저감 효과에 관한 실험적 연구)

  • Kim, Jin-Hee;Kim, Young-Tag;Lee, Soo-Yeol;Choi, Won-Ki
    • Land and Housing Review
    • /
    • v.12 no.1
    • /
    • pp.129-137
    • /
    • 2021
  • External shading devices are well known solar control devices that can help reduce the cooling load of commercial buildings. For this study, experiments were conducted to examine the feasibility of shading devices in reducing both the cooling and heating loads. The influence of sky radiant cooling during winter was verified for the external shading device, internal roller blind, and window. Results can be summarized as follows. The temperature difference between the inner and outer surfaces of the window with the external shading device was 11.8℃ compared to 14.6℃ for one without the external shading device. This 2.8℃ difference was due to heat exchange by sky radiation when the surface temperature of the shading device was lower than the ambient outdoor air temperature. The roller blind resulted in a lower temperature of 0.8℃ compared to the average temperature of the window's air cavity. This was due to heat exchange by sky radiation of the roller blind surfaces. Without shading devices, the outside surface temperature of the window is about 3℃ higher. The study also found that when external shading devices were installed on both the southwest and southeast sides, the outside surface temperature of the windows were lower on the southwest side than the southeast side.

Changes of Characteristics Related to Photosynthesis in Synurus deltoides under Different Shading Treatments (차광처리에 따른 수리취의 광합성 관련 특성 변화)

  • Lee, Kyeong-Cheol;Noh, Hee-Sun;Kim, Jong-Whan;Ahn, Soo-Yong;Han, Sang-Sup
    • Korean Journal of Medicinal Crop Science
    • /
    • v.20 no.5
    • /
    • pp.320-330
    • /
    • 2012
  • This study was conducted to investigate the changes of chlorophyll contents, chlorophyll fluorescence, photosynthetic parameters, and leaf growth of Synurus deltoides under different shading treatments. S. deltoides was grown under non-treated (full sunlight) and three different shading conditions (Shaded 88~93%, 65~75%, and 45%~55%). Light compensation point ($L_{comp}$), dark respiration ($D_{resp}$), maximum photosynthesis rate ($Pn_{max}$), photo respiration rate ($P_{resp}$), carboxylation efficiency ($\Phi_{carb}$), and photochemical efficiency were decreased with increasing shading level; However, $CO_2$ compensation point ($CO_{2\;comp}$), total chlorophyll content, and specific leaf area (SLA) were shown the opposite trend. S. deltoides under 88~93% treatment showed the lowest photosynthetic activity such as maximum photosynthetic rate ($Pn_{max}$), photochemical efficiency, and $CO_2$ compensation point ($CO_{2\;comp}$). Therefore, photosynthetic activity will be sharply decreased with a long period of 8~12% of full sunlight. With the shading level decreased, carotenoid content and non-photochemical fluorescence quenching (NPQ) increased to prevent excessive light damage. This result suggested that growth and physiology of S. deltoides adapted to high light intensity through regulating its internal mechanism.

Evaluation on the Solar Heat Gain Coefficient of Glazing System installed in internal shading device by experiments according to the NFRC 201 (NFRC 201 실험방법에 의한 내부 차양장치가 적용된 창호의 일사획득계수 평가)

  • Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.47-54
    • /
    • 2010
  • Recently the researchers has been interested in the development of the high performance windows such as solar control window using automatic shading devices, air-flow window, selective coating window. In order to assess the energy performance of total fenestration system, the net energy gains or losses through the glazings and windows should be evaluated. It depends on the thermal transmittance (U-value) and the total solar energy transmittance (SHGC, g-value). This study aims to measure the solar heat gain coefficient according to the NFRC 201 standard test method. In results, we could find the result of different SHGC of the glazing system with a different slat angles. The SHGC in case of $90^{\circ}$ of internal slat angle with regard to the window surface is about 0.56, that in case of $45^{\circ}$ is about 0.49 and that in case of $0^{\circ}$ is about 0.33. Significant dependence on the solar radiation intensity and incident angle was found in comparison of the measured and simulated SHGC.

Optimum Control of a Photoelectric Dimming System in a Small Office with a Double Skin Envelope

  • Kim, Soo Young;Yum, Sung Kon
    • Architectural research
    • /
    • v.7 no.2
    • /
    • pp.47-54
    • /
    • 2005
  • A photoelectric dimming control system for a small private office space with a double skin envelope system was analyzed for the purpose of examining optimum control performances under a variety of daylight conditions. Computer simulations were performed for the three different photosensor types positioned at the center of ceiling in the space. They were applied in both a south and north-facing room. Daylight conditions were a fixed horizontal venetian blind on an external envelope and a retractable shading device on an internal envelope under a clear, intermediate and overcast sky at different times of a day and year. Partially-shielded photosensors provided good control performances providing the required electric light output under clear and intermediate sky conditions. Unshielded photosensors failed to provide necessary illuminance levels producing less electric output and fully-shielded photosensors generally provided excessive light output. Reasonable electric lighting energy savings were achieved except under overcast sky conditions where the control system did not contribute to energy savings due to the less daylight through envelopes. The retractable shading device covering 50% of the internal envelope reduced energy savings up to 19.62%, but the workplane illuminance levels were maintained within recommended ranges. The coefficients of determination between workplane illuminance and photosensor illuminance due to daylight ranged from 0.74 to 0.98. Partially-shielded conditions provided best correlations and the north-facing room yielded stronger correlation than the south-facing room.

A Study on the External Wall Heating Temperature Distribution According to Opening Upper Shading Installation and Length (개구부 상부 차양설치 및 길이에 따른 외벽 수열온도분포에 관한 연구)

  • Jung, Ui-In;Hong, Sang-Hun;Kim, Bong-Joo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.4
    • /
    • pp.339-345
    • /
    • 2020
  • This study used a real-scale model experiment to reproduce internal fires in residential buildings such as a multi-dwelling unit, in order to prevent damage caused by tens of thousands of fires witnessed each year and to take measures to cope with them. For experimental conditions, different opening sizes were applied to measure and analyze the heating temperature of the exterior wall. Results drawn are as follow : On top of this, the experimental conditions had whether to install shading and put a shading length differently, before measuring and analyzing the heating temperature of the exterior wall. Subsequent results were drawn as shown below. Based on the maximum temperature, the temperature was lowered as much as around 90℃ at 150mm, around 150℃ or over at 300mm and over 175℃ at 450mm. It also turned out that the difference in maximum temperature dropped by around 180℃ or over. This indicated that the shading installation works well in lowering flame temperature generated by fire spread of the exterior wall.

A Study on Drone Nozzle Design for Greenhouse Shading (온실차광을 위한 드론 전용노즐 설계에 관한 연구)

  • Ungjin Oh;Jin-Taek Lim
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.24 no.4
    • /
    • pp.249-254
    • /
    • 2023
  • Recently, the distribution of drones is being activated by saving farmers' working time and protecting them from harmful human bodies from pesticides due to the mission of spraying pesticides using drones. It is possible to compensate for various shortcomings derived from the existing pesticide spraying method, wide-area control and helicopter control. Recently, the smart farm expansion policy has actively used it to generate profits for farmers by increasing harvests by monitoring growth information of various crops based on IoT in real time and collecting big data on key variables, and related drone industry technologies are also being developed. In this study, drones were applied to the work of shading greenhouses to secure diversity in agricultural application fields, and basic research on the greenhouse environment was conducted to materialize the technology related to shading. In order to provide high-quality light in consideration of the internal and external environment of the green house, basic research was conducted to enable light-shielding missions using drones through nozzle design for uniform spraying of nozzles of drones, light-transmitting rate analysis of green houses, and light-shielding agent application experiments.