• Title/Summary/Keyword: insulation system

Search Result 1,387, Processing Time 0.04 seconds

Performance Requirement of Cast-in-place Concrete with Sandwich Insulation (타설형 콘크리트 중단열 벽체의 요구성능 분석)

  • Park, Jun-Ho;Yu, Jung-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.10-11
    • /
    • 2014
  • Energy load of building affected by insulation performance of building's exterior. and insulation system can be classify interior insulation, exterior insulation, sandwich insulation according to install place of insulation. but within interior insulation system, corner wall and the cross outer wall-slab insulation part may occur thermal bridges. And then, within exterior insulation system is more superior insulation performance than interior insulation, but it has difficult to apply, easily broken at high building because of strong wind load. And also difficult to maintenance exterior insulation system. So, in this study, to found requirement performance of cast-in-place sandwich insulation system that is superior insulation performance and easy construction and maintenance. requirement performance of cast-in-place sandwich insulation system is 1) To avoid thermal bridges in the insulation performance, 2) Both sides concrete wall can be composite action in the structural performance. Because of this study, can develops cast-in-place sandwich insulation system and this insulation system contribute to improve insulation performance of apartment-house and high building.

  • PDF

Problem Analysis of Sandwich Insulation Wall System (중단열 시스템의 문제점 분석)

  • Park, Jun-Ho;Yu, Jung-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.166-167
    • /
    • 2015
  • Because of energy crisis at all around the world, there is many method and system which for improving energy efficiency has appeared in construction industry. And then, 20% of entire building energy loss is emissed to exterior of buildings, that is important to building's entire energy efficiency. So, many research has been conducted for imporve exterior energy efficiency and generally it called insulation of wall. Method for wall insulation can be classified interior system and exterior system which defined installation place of insulation board whether interior or exterior of structural wall. However, interior system has thermal problem such as thermal-bridge which can be necessarily occur condensation. and exterior system has constructional problem such as difficult to construction because exterior and finish work so expensive construction cost than other insulation method. Thus, sandwich insulation wall system has been appeared for solving these problems. Sandwich insulation system must using wall connecting things because both side walls is divided by center insulation. At this, Through the heat at wall connecter, it can be occured thermal-bridge and broken insulation board when under construction will be bring negative effect by reducing wall thickness and insulation deficit. At this study, we were compared previous sandwich insulation system and analysis these system's problem for develop the improving constructability and performance of sandwich insulation system.

  • PDF

Study on insulation coordination of 154KV solidly grounded system (154KV계 직접접지시의 절연협조)

  • 신대승
    • 전기의세계
    • /
    • v.17 no.3
    • /
    • pp.57-61
    • /
    • 1968
  • Limitation to Peterson coil grounded operation of 154KV system began to develop with the growth of system as to voltage and system cost. Therefore, 154KV system is going to be grounded solidly from November this year. This study shows the insulation coordination of solidly ground system, such as the selection of a suitable lightening arrester, determination of transmission line insulation and Basic Insulation Level of station equipment.

  • PDF

Evaluation of Aging on Coil Insulation System for Rotating Machines (고압회전기 절연시스템 열화특성분석을 통한 성능평가)

  • Choi, Young-Chan;Kim, Hong-Je;Seo, Dong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.922-924
    • /
    • 2000
  • We worried about the technology difference between our company and the advanced companies at present motor market. Thus we started independently to develop the technology of motor coil insulation system and to accumulate insulation technology data. When we export the electric machines to oversee market. we are asked to set up the insulation system to show our product excellence. We first evaluate the insulation system of our motors to realize higher reliability of high voltage insulation system. Therefore we are possible to do the insulation diagnosis in real site and have accumulated the data related in insulation diagnosis. Thus we have improved the our insulation system. And also these data were used to new product development as very useful data. also will be used the insulation deterioration diagnosis to estimate the remained life time which is very important data for the maintenance management. As the result. we are able to get the our product reliability.

  • PDF

Design & system construction of insulation on the traction motor for EMU (철도차량용 견인전동기의 절연설계 및 절연시스템 구성)

  • 왕종배;홍선호;조연옥;김명룡
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.194-197
    • /
    • 2001
  • Traction motors driven by high speed switching inverters is demanded higher operating temperature, severe duty cycles, higher starting current, frequent voltage transients and finally severe environmental exposure. For applications to inverter duty, traction motors needs a special insulation system, which has characteristics of increased bond strength, lower operating temperature and higher turn-to-turn insulation. In this paper, design considerations and manufacturing procedure of 200 Class insulation system with polyimde(Kapton) main insulation and silicone resin VPI process on the traction motor for EMU will be reviewed. And performance test and long life evaluation test which prove stability and long life evaluation test which prove stability and reliability of insulation system for traction motor will be introduced.

  • PDF

A Study on the Development of Traction Motor for Electric Railway: Insulation System Design & Performance Test

  • Wang, Jong-Bae
    • Transactions on Electrical and Electronic Materials
    • /
    • v.2 no.4
    • /
    • pp.19-23
    • /
    • 2001
  • In this paper, design considerations and manufacturing procedure of 200 class insulation system with polyimide(Kapton) main insulation and silicone resin VPI process on the traction motor thor EMU will be reviewed. The performance test and the long life evaluation test that prove stability and reliability of Insulation system for traction motor will also be introduced.

  • PDF

A Study on the Development of Prototype for Green Roof System in Korea (한국형 Green Roof System 개발을 위한 Proyotype 제안)

  • Kim, Hyen-Soo
    • KIEAE Journal
    • /
    • v.3 no.3
    • /
    • pp.3-11
    • /
    • 2003
  • The purpose of this study is to develope an available outdoor insulation construction for the green roof system in Korea. On its own economical and structural problems of constructional risk, the typical outdoor insulation construction on the korean spot does not function efficiently with the green roof. Therefore, this study consists of four main contents as follows: 1. The objectives of the study are established by analysing the problems of the typical in- and outdoor roof insulation system in korea. 2. The foreign outdoor insulation systems for the green roof are clarified to find out an acceptable prototype for Korea. 3. According to loadtest, the prototype, which has a waterproof on the thermal insulation, is tested to demonstrate the structural safety. 4. The U-value test of the prototype on KS F 2277 brings the thermal performance of the green roof system, which can influence the thickness of the insulation.

Thermal Performance Evaluation of Movable Insulation System in Apartments (공동주택 발코니창에 설치된 가동단열 시스템의 열성능 평가)

  • Yoon, Jong-Ho;Kim, Byoung-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.28-35
    • /
    • 2008
  • The aim of this study was to analysis the Heating/cooling performance of movable insulation system built in apartments. The process of this study is as follows: 1) Test-cells of movable insulation are designed through the investigation of previous paper and work. The type of the movable insulation used in test-cell is low emissivity(5%) insulation, measured for heating season and the thermal effects are analyzed. 2) The simulation program(Design Builder) was used in energy performance analysis. the reference model of simulation was made up to analysis energy performance on movable insulation system. 3) Selected reference model(Floors:15, Area of Unit:115.5$m^2$) for heating/cooling energy analysis, Energy performance simulation with various variants, such as slate angle of movable insulation(5$^{\circ}$, 30$^{\circ}$, 50$^{\circ}$) and position of movable insulation. Consequently, When movable insulation system is equipped with balcony window of Apartment, Annual heating energy of reference model was cut down at the average of 5.4kWh/$m^2$ or 4.6% of heating/cooling energy.

Evaluation of Building Envelope Performance of a Dry Exterior Insulation System Using Truss Insulation Frame (트러스 단열 프레임을 이용한 건식 외단열 시스템의 외피 종합 성능 평가)

  • Song, Jin-Hee;Lee, Dong-Yun;Shin, Dong-Il;Jun, Hyun-Do;Park, Cheol-Yong;Kim, Sang-Kyun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.6
    • /
    • pp.153-164
    • /
    • 2019
  • The presence of thermal bridges in a building envelope cause additional heat loss which increases the heating energy. Given that a higher building insulation performance is required in these cases, the heat loss via thermal bridges is a high proportion of the total heat energy consumption of a building. For the dry exterior insulation system that uses mullions and transoms to fix insulation and exterior materials such as stone and metal sheet, the occurrence of thermal bridges at mullions and transoms is one of the main reasons for heat loss. In this study, a dry exterior insulation system using the truss insulation frame (TIF) was proposed as an alternative to metal mullions. To evaluate the building envelope performance, structural, air-leakage, water-leakage, fire-resistance, thermal, and condensation risk tests were conducted. In addition, the annual energy consumption associated with heating and cooling was calculated, including the linear thermal transmittance of the thermal bridges. As a result, the dry exterior insulation system using TIF achieved the allowable value for all tests. It was also determined that the annual heating load of a building was reduced by 36.7 % when the TIF dry exterior insulation system was used, relative to the dry exterior insulation system using steel pipes without additional insulations.

A technology State of Life Estimation and Insulation Diagnosis for High Voltage Rotating Machine (고압회전기 절연진단 및 수명평가 기술현황)

  • Choi, Young-Chan;Wang, Jong-Bae;Kim, Ki-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.31-35
    • /
    • 2000
  • We worried about the technology difference between our company and the advanced company at present motor market and are asked to set up the independent coil insulation system to accumulate insulation technology data. And to export our products at oversee market, we are asked to the evaluation of insulation performance to show our product excellence. In this study, we evaluated the insulation system of our motor, and studied the insulation diagnosis technology systematically to do site diagnosis. We are now accumulating the measured data. And also to reduce the initial insulation failure, we performed the insulation characteristic test and acquired the data to evaluate the initial soundness. We are doing the improvement of the insulation system. And also these data were used to new product development as very useful data, also will be used in the insulation deterioration diagnosis to estimate the remained life time which is very important data for the maintenance management. As the result, we were able to get our product reliability.

  • PDF