A Study on the Lighting for Dancing Art (무용예술을 위한 무대조명에 관한 연구)

  • Lee, Jang-Weon;Yi, Chin-Woo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.218-223
    • /
    • 2009
  • Even though the movement of human body contruct the primary factor of Dancing Art, spectators appreciate more meaningful expression of the stage that stand above limited space and time. Lighting is a distinctive expressive mechanism of obvious line, form and rhythem of human body by marking a light and shade through artificial beams into the stage. As Dancing art is different from drama, lighting of dancing stage should be distinguished from that of drama stage.

  • PDF

Transient Current Control of Two-Stage Electronics Ballast for HID Lamps (HID 램프용 Two-Stage 전자식 안정기의 과도 전류 제어)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • The conventional Three-Stage electronic ballast is stable, but Two-Stage electronic ballast has been researching because of efficiency. Three-Stage electronic ballast is consisted of PFC circuit, buck converter, and inverter circuit, but Two-stage is consisted of PFC circuit, Buck-Inverter full bridge circuit. The Buck-Inverter full bridge inverter consists of two half bridge inverters for low frequency switching, and high frequency switching. In the case of street lamp it is far from a lamp to a ballast, the conventional pulsed high voltage ignitor can not turn on the HID lamps because of reduction of ignition voltage. Therefore, it needs to do the research on a resonant ignition to turn on the HID lamps. Therefore, in the Two-Stage electronic ballast which has the resonant tank for ignition, the transient resonant current because of low frequency changing is analyzed, the novel algorithm is proposed to resuce the transient current.

A Study on the Fire Protection System in the Stage (공연장의 소방시설 설치기준의 개선방안에 관한 연구)

  • 장상태;이영재
    • Fire Science and Engineering
    • /
    • v.13 no.4
    • /
    • pp.13-19
    • /
    • 1999
  • Currently, conventional fire prevention facility installation standard is based on the use and size of the domestic theaters. In the study, theaters with 1,900 seats were examined to suggest a suitable method to adapt a better fire preventing system. The proposed systems are as follow. - 100% of backup pressed-water outlet device, considering waterproof pressure for fire prevention facility at the top floor. - The supplement of the side wall type header and a large caliber outlet header for stage open sprinkler. - Subdividing a installation rule for special detector and implementing the latestdetector. - Installation of fire curtain for dividing stage area and auditorium area, and also the method of installation of fire curtain.

  • PDF

Evaluation of Numerical Models for Analysing an Industrial Centrifugal Blower (산업용 원심블로어 수치해석을 위한 수치모델 평가)

  • Lee, Jongsung;Jang, Choonman
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.6
    • /
    • pp.688-695
    • /
    • 2012
  • The present study represents the effects of boundary condition on the performance of a centrifugal blower at the interference plane between rotational and stationary domains using three dimensional compressible Navier-Stocks equations. Two boundary conditions, frozen-rotor and stage, are compared to analyze the blower performance. Installation angle between the cutoff of a volute casing and a impeller blade is also introduced to evaluate the blower performance and to understand the internal flow inside the blower. Throughout numerical simulation, it is found that the frozen rotor interface method at the interference plane represents well the variations of flow field inside the blower compared to stage interface method. However, pressure has maximum two percent error according to the installation angles while pressure is almost constant for the stage interface method. And stage interface method can relatively well predict the blower performance. Detailed internal flows of the centrifugal blower are compared and analyzed by numerical simulation.

A Study on the Analysis of Field Condition for Ground Fault Protection Installation among Electrical Installations in the Entertainment Area (공연장의 전기설비중 지락보호설비에 대한 현장실태분석 연구)

  • Bae, S.M.;Kim, H.S.;Gil, H.J.;Lee, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1721-1723
    • /
    • 2002
  • This paper deals with the analysis of field condition for earth leakage current alarming system in the stage lighting, stage sound stage machinery installation. These analyses of field condition were carried out in accordance with investigating an installation of earth leakage current alarming system with respect to a main line of power source, dimmer, sound equipment, machinery mobile unit equipment and so on. As a result of analyses. The earth leakage current alarming system has been installed only a part of the main line of power source and the probability of places which were installed was less than 50(%). Therefore, it is desirable that the earth leakage current alarming system is installed at places which are suitable, for example, dimmer, each kind machinery etc. in order to prevent electrical hazard.

  • PDF

A Study on the Stage Lighting Design by the Type of Performance Hall (극장 형태에 따른 무대조명 디자인 기법에 관한 연구)

  • Lee, Jang-Weon;Kim, Myung-Nam
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.224-229
    • /
    • 2009
  • A Study on the Stage Lighting Design by the Type of Performance Hall The purpose of this study is to inquire into the practice of lighting design which is changed by type of stage Proscenium Stage, Thrust Stage, Arena Stage, and Flexible Stage, which have originated from ancient Greek theatre and are still used in contemporary theatre. This studt takes a good at the practical application of lighting design to different types of stage, through which it is expected to improve the understanding of lighting as a part of performing arts and to develop the quality of stage arts. The way of lighting design by type of stage can be acstracted as the following. This is expected to be of a great help to stage arts as well as different lighting designs for each type of stage. The methodology of lighting design might have limits in its application to practice in the current war Id where theatre structures and lighting equipments are fast-developing and ever-changing. However, lighting design can develop based on the basic design concepts as the researches of all fields can develop by applying their basic theories.

  • PDF

A Study on PFC of Active Clamp ZVS Flyback Converter (능동 클램프 ZVS 플라이백 컨버터의 역률개선에 관한 연구)

  • 최태영;류동균;이우석;안정준;원충연;김수석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.49-57
    • /
    • 2001
  • This paper analyzed PFC of active clamp ZVS flybark converter by adding two method PFC (Power Factor Correction) circuit-two-stage and single-stage. The addition of active clamp circuit also provide a mechanism fur achieving ZVS of both the primary and auxiliary switches. ZVS also limits the turn off di/dt of the output rectifier, reducing rectifier switching loss and switching noise, due to diode reverse recovery. As a results, the proposed converters have characteristics of the reduced switching noise and high efficiency in comparison to conventional flyback converter. The simulation and experimental results show that the proposed converters improve the input PF of 300[W] ZVS flyback converter by adding single-stage two-stage PFC circuit.

  • PDF

A Study on the Reciprocal Relationship Between Dance Choreography and Stage Lighting (무용안무와 무대조명의 상호적 관계에 관한 연구)

  • Chang, So-Jung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.10-13
    • /
    • 2015
  • Stage lighting plays a significant role in drawing out the mood and images that are intended by the choreographer. It is related to the dancers' movements and affects them both directly and indirectly. This study is on a reciprocal relationship between dance choreography and stage lighting, covering a broad range of functional factors of lighting effects on the dance choreography. Also, the data on preferred lighting colours and their frequency of usage are gathered through surveys by lighting specialists. The data is used to identify the lighting colour in general dance choreography. It is collected to serve the purpose of providing opportunities to acknowledge the needs of various colour changes on the stage. It is hoped that a collaboration of studies related in this subject are continuously promoted and researched in producing high quality dance performances.

A study on the Comparison of Illuminace Simulations and Measured Values at the Stage Lighting (무대조명에서의 조도 시뮬레이션 결과와 실측값 비교 연구)

  • Lee, Jang-Weon;Yi, Chin-Woo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.230-234
    • /
    • 2009
  • In a planning of the Stage lighting, we carry out illumination simulation. After lighting construction we measured illuminance in order to compare the simulation results. And we study the errors between them.

  • PDF