• Title/Summary/Keyword: installation expense

Search Result 26, Processing Time 0.023 seconds

Development of Heating Technology for Greenhouse by Use of Ground Filtration Water Source Heat Pump (여과수열원 히트펌프를 이용한 온실난방기술 개발)

  • Moon, J.P.;Lee, S.H.;Kang, Y.K.;Lee, S.J.;Kim, K.W.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.172.2-172.2
    • /
    • 2010
  • This study was carried out in order to reduce the installation expense of heating system for greenhouse comparing to geothermal heat pump and develope the coefficient of performance (COP) for a heat pump. For getting plenty of heat flux from geothermal energy. Surface water in river channel was used for getting a lots of geothermal heat by penetrating water through underground soil layer of the river bank that make heat transmission to passing water. The range of water temperature after the process of Ground filtration is 13~18 degrees celsius which is very similar to low heat source of geothermal heat pump system and the plenty amount of heat source from that make the number of geothermal heat exchanging hole and the expense for geothermal heat exchanger construction reduced. Drainage well is also used for returning filtration water to the aquifer that keep the water good recirculation from losing geothermal heat and water resource. For the COP improvement of Heat pump, thermal storage tank with separating insulation plate according to the temperature difference make the COP of Heat pump that is similar to thermal storage tank with diffuser. Developed thermal storage tank make construction expense cheaper than customarily used one's. and that sand filter and oxidation sand (FELOX) are going to be used for improving ground filtration water quality that make heat exchanger efficiency better. All above developed component skill are going to be set on the Ground filtration water source heat pump system and applied for medium, large scale for protected greenhouse in riverside area and on-site experiment is going to do for optimizing the heating system function and overcome the problem happening in the process of on-site application afterward.

  • PDF

A Differential Pricing Model for Industrial Land based on Locational Characteristics (입지특성을 고려한 토지가격의 차등적 산정방안 - 산업시설용지 공급가격을 중심으로 -)

  • Shim, Jae Heon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2D
    • /
    • pp.303-314
    • /
    • 2011
  • This paper proposes a differential pricing model for industrial land based on locational characteristics, using Support Vector Regression (SVR) as a land pricing methodology. The initial selling price of industrial land is set based on the total cost of site development that comprises the land acquisition cost and tax, land development expense, infrastructure installation cost, labor cost, migration expense, selling and administrative expense, capital cost, and so on. However, the current industrial land pricing method unreasonably applies the same price per square meter to all parcels within an industrial complex without considering differences in price depending on the location of each parcel. Therefore, this paper proposes an empirical land pricing model to solve this irrationality and verifies its validity and applicability.

Practical Design of an Artificial Light-Used Plant Factory for Common Ice Plant (Mesembryanthemum crystallinum L.) (인공광 이용형 Common Ice Plant 식물공장의 실용적 설계)

  • Cha, Mi-Kyung;Kim, Ju-Sung;Shin, Jong Hwa;Son, Jung Eek;Cho, Young Yeol
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.371-375
    • /
    • 2014
  • This study was carried out to get the basic data to practically design an artificial light-used plant factory system for common ice plant (Mesembryanthemum crystallinum L.) cultivation. The adequate range of light intensity was $120-200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ and the carbon fixed rates was $0.84nmolCO_2{\cdot}cm^{-2}{\cdot}s^{-1}$. When the planting density, light intensity, and yield were $0.0225m^2$ ($15{\times}15cm$), $200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, and 1,000 plants per day, the total number of the plants, cultivated area, and total light intensities were estimated as 25,000 plants, $563m^2$, and $140,625{\mu}mol{\cdot}s^{-1}$, respectively. About 153.2kW with 2,785 fluorescent lights (FL) needed for the electric power and the electricity charges was 2.46 million won for one month. At a harvest rate of 1,000 plants per day in closed-type plant factory, the light installation cost, total installation cost, and total production cost were 27.85, 83.56, and 100.27 million won, respectively. The production cost per plant including labor cost was calculated as 370 won, providing that the cultivation period was 25 days and marketable ratio was 80%. Considering the annual total expenses, incomes, and depreciation cost, the sales cost per plant could be estimated around 970 won or higher.

Development of Boost Type Bidirectional ZCS DC/DC Converter For EV of Transformer Series Construction (변압기 직렬구조의 EV용 승압형 양방향 ZCS DC/DC 컨버터 개발)

  • Choi, Jung-Sik;Park, Byung-Chul;Chung, Dong-Hwa;Song, Sung-Gun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.37-46
    • /
    • 2013
  • This paper proposes the boost type bidirectional zero current switching(ZCS) DC/DC converter of transformer series construction for electric vehicle operation using low voltage battery. This converter can high boost through the double voltage circuit and series construction of output part using two converters. This converter system has the advantages that bidirectional power transfer is excellent, size and making of transformer because of this converter keeps the transformation ratio to 1:1. Proposed DC/DC converter uses the ZCS method to decrease the switching loss. By replacing reactance ingredients of L-C resonance circuit for ZCS with leakage inductance ingredients of high frequency transformer and half-bridge capacitor it reduces system size and expense because of not add special reactor. It can confirm to output of high voltage to operate the electric vehicle with low voltage of input and operation of ZCS in all load region through the result of PSIM simulation and experiment.

Design and Implementation of Voice Usenet Newsgroup Service System for Visual Disabilities (시각장애인을 위한 음성낭독 유즈넷 뉴스그룹 서비스 시스템의 설계 및 구현)

  • 조철환;장영건;박찬곤;홍승홍
    • Proceedings of the IEEK Conference
    • /
    • 2000.06c
    • /
    • pp.129-132
    • /
    • 2000
  • It is difficult to find web contents for visual disabilities in spite of rapid growing internet users, infrastructures and advance of computer technology. For the case of usenet newsgroup concerning disabilities, hit rate is even less than E-mail because of lack of accessibility, educational support and economical expense for internet. This paper is addressed to voice usenet newsgroup service by using telephone or web browser for visual disabilities without additional S/W support such as 775, usenet program and installation program, suggests a design method and an implementation example for it. Main features of it are easiness of man machine interface, popularity of access device such as telephone or web browser and independency of particular news server by using NNTP. This system supports general MIME format, is implemented for usenet server of Korean Social Worker's Community and will be implemented for Gomduri InfoNet BBS of Korean Society for Rehabilitation of Persons with Disabilities.

  • PDF

Relationship of Restaurant Physical Environment and Payment Price (레스토랑 물리적 환경과 지불가격의 관계)

  • 임붕영;김형준
    • Culinary science and hospitality research
    • /
    • v.10 no.2
    • /
    • pp.135-148
    • /
    • 2004
  • Research there is a place objective which searches the importance of physical environment. Namely, there is a place objective which defines the effect relationship of physical environment and payment price. The analysis result physical environment appeared in 6 items. (interia, hygiene, illumination, the color body and atmosphere, space, movement and the command installation). The item which causes a big effect in price appeared with the interia and atmosphere. The upgrade of the interia and atmosphere of the restaurant increases the price it will be able to pay letting with the customer is judged with the fact that role. Currently the restaurant service or importance of specialty knowledge of the work unit field is embossed. But, the customer pays an expense and the item which is important it will be able to create a value is showing is physical environment.

  • PDF

A Study on the Sensitivity Analysis of Offshore wind farm Design (해상풍력발전 단지배치에 따른 민감도 분석에 관한 연구)

  • Kim, Do-Hyung;Jang, Eun-young;Kyong, Nam-Ho;Kim, Hong-Woo;Kim, Sung-Hwan;Kim, Chang-Suk
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.29-35
    • /
    • 2011
  • This study draws economic expense factors according to the influence of generation resulted from slipstream and the arrangement of the complex when arranging and designing the complex for offshore windpower development as a model of 50MW offshore wind farm and conducts economics analysis. According to the result of the analysis, O (Optimize) arrangement was the one that has the highest generation for having the best windpower resources in terms of design and being least affected by slipstream; however, the arrangement requires expensive submarine cables and high installation cost. Therefore, according to the analysis of economics, it was thought that 50MW complex should have less economics as BC ratio 0.95 than the series arrangement of main wind direction and I+80 series arrangement would be rather more economical. This economics evaluation provides comparison according to the arrangement of the development complex considering the uncertainty of the electricity price and gross construction cost. And it is expected that the result of economics evaluation would greatly differ by installation capacity, and the reason is that the cost of electric infrastructure takes up a higher portion than the gross construction cost of the development complex. The only way to compensate this part is to make the windpower development complex larger. It seems that it will be necessary to enhance spot applicability to evaluate economics afterwards and pay consistent attention to and conduct follow-up research on the economics evaluation of the complex construction.

A Study on the Analysis of Efficiency for Underground Distribution Equipment by Installment Ways (지중배전공사에 설치되는 기기의 설치위치에 따른 영향 분석에 관한 연구)

  • Kim, Joon-Eel;Kim, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.83-89
    • /
    • 2009
  • The environment of electrical power industry is now faced on problems such as electric rates, an increasing sensitivity in society with environmental issues and energy factors. Up to now, reliability is greatly influenced by maintenance and environmental factors that are unique to the electric utilities. The reliability is a characteristic assigned to the electric power systems's function which is related to the concept of installment of equipment. Therefore this reports's key finding is that it is important that the utilities track their individual components' value over investment expense of their installed components. This can be accomplished to consider the cases of foreign electric power companies and take into account the various possible installment ways of equipment in Korea. These results are expected to be used as a reference material for design underground distribution facilities and future applications.

Bridge between IEEE 802.15.4 and IEC 61850 using Raspberry Pi (라즈베리파이를 이용한 IEEE 802.15.4와 IEC 61850 간의 브리지)

  • Hwang, Sung-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.5
    • /
    • pp.181-186
    • /
    • 2017
  • IEC 61850 is a standard for power utility automation. Using IEC 61850 that uses ethernet may consume more costs for the automation than its value in small distribution substations. Thus, less expense and installation cost are required for the automation of small distribution substations. This study used inexpensive and easy-to-install IEEE 802.15.4 and implemented a bridge between IEC 61850 and IEEE 802.15.4, using Raspberry Pi to connect the existing IEC 61850. Using IEEE 1588, IEC 61850 traffic performances were evaluated, such as SV, GOOSE and MMS. Analyzing IEC 61850 requirements and performance evaluation results, the scope of application of IEEE 802.15.4 was decided.

Compensation for Photovoltaic Generation Fluctuation by Use of Pump System with Consideration for Water Demand

  • Imanaka, Masaki;Sasamoto, Hideki;Baba, Jumpei;Higa, Naoto;Shimabuku, Masanori;Kamizato, Ryota
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1304-1310
    • /
    • 2015
  • In remote islands, due to expense of existing generation systems, installation of photovoltaic cells (PVs) and wind turbines has a chance of reducing generation costs. However, in island power systems, even short-term power fluctuations change the frequency of grids because of their small inertia constant. In order to compensate power fluctuations, the authors proposed the power consumption control of pumps which send water to tanks. The power control doesn’t affect water users’ convenience as long as tanks hold water. Based on experimental characteristics of a pump system, this paper shows methods to determine reference power consumption of the system with compensation for short-term PV fluctuations while satisfying water demand. One method uses a PI controller and the other method calculates reference power consumption from water flow reference. Simulations with a PV and a pump system are carried out to find optimum parameters and to compare the methods. Results show that both PI control method and water flow calculation method are useful for satisfying the water demand constraint. The water demand constraint has a little impact to suppression of the short-term power fluctuation in this condition.