• Title/Summary/Keyword: inferior

Search Result 2,982, Processing Time 0.035 seconds

Reoperation for the Missed Inferior Sinus Venous Atrial Septal Defect (잔여 하정맥동형 심방중격결손증의 재수술)

  • Yoo Byung Su;Jho Tae Jun;Kim Kun Il;Lee Jae Woong;Hong Ki Woo;Lee Weon Yong
    • Journal of Chest Surgery
    • /
    • v.39 no.2 s.259
    • /
    • pp.154-156
    • /
    • 2006
  • Inferior sinus venosus ASD (atrial septal defect) is a rare congenital cardiac deformity, that occurs on between the inferior vena cava and right atrium. Diagnosis of inferior sinus venosus ASD is difficult because of its infero-posterior location of the fossa ovalis. Therefor, exact anatomical diagnosis by preoperative and intraoperative transesophageal echocardiography is necessary at preoperation and during the operation. We present a case of residual ASD, which was diagnosed secundum ASD and repaired when the patient was 10 years old. Residual ASD was diagnosed by cardiac echocardiography in preparation of otorhinolaryngology operation. Therefore, reoperation of residual ASD was done when the patient was 24 years old. The patient had secundum ASD and inferior sinus venosus ASD, but in the prior operation, inferior sinus venosus ASD wasn't found and only secundum ASD was repaired. In reoperation, inferior sinus venosus ASD was reveled and patch closure was done.

The Mid-term Results of Inferior Capsular Shift Procedure for Multidirectional Instability of the Shoulder (견관절 다방향 불안정성의 하방 관절낭 이동술에 대한 중간 추시 결과)

  • Rhee Yong Girl;Cho Chang Hyun;Lee Jae Hoon
    • Clinics in Shoulder and Elbow
    • /
    • v.3 no.1
    • /
    • pp.1-9
    • /
    • 2000
  • Purpose: To report the mid-term results of the inferior capsular shift procedure for the multidirectional instability, and to analyze whether the bilateral laxity, the generalized ligamentous laxity and the voluntary instability can influence upon the final outcome. Material and Method: We reviewed 95 patients with 96 shoulders treated by the inferior capsular shift procedure for multidirectional instability through an anterior approach. In total, 49 shoulders(51%) showed generalized ligamentous laxity, 56 shoulders(58%) bilateral laxity, and 65 shoulders(68%) voluntary subluxation. Mean follow-up was 27 months(11-60 months). Result: The final Rowe score was 75 points in patients who had had at least one of the bilateral laxity, generalized ligamentous laxity, or the voluntary subluxation and 84 points without any of these in each element. Seventy-five percent of the bilateral laxity and 87% of the unilateral instability continued to function well without any pain and instability postoperatively. Those with a voluntary(74%), those with an involuntary instability(83%), those with a generalized ligamentous laxity(73%) and without laxity(84%) could do well a daily living activity without instability Eighty-six percent who had had the voluntary instability was eliminated completely the voluntability. Eighty-four percent of the patients stated that they were subjectively satisfied with the status of their shoulder. Nine shoulders(9.4%) had recurrence of symptomatic and disabling instability and theses patients had had at least voluntary instability preoperatively. Seven patients(7.3%) suffered from the stiff shoulder after the inferior capsular shift procedure. Conclusion: The inferior capsular shift procedure in multidirectional instability provided satisfactory results both in objective and subjective terms. Nonetheless, a patient who has a bilateral laxity, a generalized ligamentous laxity or a voluntary instability could be expected less favorable results compared to those with neither of these. A careful selection of the inferior capsular shift procedure for the multidirectional instability is needed before surgery. But our results suggests that a voluntary instability is not always poor candidate for the inferior capsular shift procedure.

  • PDF

THE STUDY ON COURSE OF THE INFERIOR ALVEOLAR CANAL IN THE MANDIBULAR RAMUS USING CONEBEAM CT (하악지에서의 하치조신경관 주행에 대한 Conebeam CT를 이용한 연구)

  • Kim, Hyong-Woo;Kwon, Kyung-Hwan;Min, Seung-Ki;Oh, Seung-Hwan;Chee, Young-Deok;Koh, Se-Wook;Lee, Jae-Hwan;Ohn, Byung-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.5
    • /
    • pp.386-393
    • /
    • 2009
  • Objectives: This study was performed to evaluate course of the inferior alveolar canal in the mandibular ramus and to find safety zone when ramal bone is harvested. Patients and Methods: From January, 2009 to February, 2009, the 20 patients who visited in the Department of Oral and Maxillofacial Surgery, Sanbon Dental Hospital. Wonkwang University and the Conebeam CT was taken of various chief complaints, were selected. The patients who had left and right mandibular first molar and incisor missing, jaw fracture and bone pathology were excluded. The R point was defined as the point which occlusal plane was crossed to the mandibular anterior ramus(external oblique ridge). In the cross-sectional coronal and axial views, the inferior alveolar canal position to the R point, buccal bone width(BW), alveolar crest distance(ACD), distance from alveolar crest to occlusal plane(COD) and inferior alveolar canal to sagittal plane(CS) were measured and horizontal distance(HD), vertical distance(VD) and nearest distance(ND) were measured. Results: The inferior alveolar canal is located $6.19{\pm}1.21\;mm$ from the R point. Horizontal distance from the R point were $13.07{\pm}2.45\;mm$, vertical distance from the R point were $14.24{\pm}2.41\;mm$ and nearest distance from the R point were $10.12{\pm}1.76\;mm$. The course of the inferior alveolar canal was positioned within $0.61{\pm}0.68\;mm$. The distance from external buccal bone to the inferior alveolar canal was increased from the R point anteriorly. Conclusions: It is considered that the mandibular ramus from the R point to 10 mm anteriorly can be harvested safely at ramal bone grafting.

MORPHOMETRICS OF ALVEOLAR PROCESS AND ANATOMICAL STRUCTURES AROUND INFERIOR MAXILLARY SINUS FOR MAXILLARY IMPLANTATION (임플랜트 시술을 위한 치조돌기와 상악동 주변 구조물의 형태계측적 연구)

  • Park, Ju-Jin;Lee, Young-Soo;Paik, Doo-Jin;Park, Won-Hee;Yoo, Dong-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.228-239
    • /
    • 2007
  • Statement of problem: Following tooth loss, the edentulous alveolar process of maxilla is affected by irreversible reabsorption process, with progressive sinus pneumatization leads to leaving inadquate bone height for placement of endosseous implants. Grafting the floor of maxillary sinus by sinus lifting surgery and augmentation of autologous bone or alternative bone material is a method of attaining sufficient bone height for maxillary implants placement and has proven to be a highty successful. Purpose: This study was undertaken to clarify the morphometric characteristics of inferior maxillary sinus and alveolar process for installation of implants. Material and method: Nineteen skulls (37 sinuses, 10M / 9F) obtained from the collection of the department of anatomy and cell biology of Hanyang medical school were studied. The mean age of the deceased was 69.9 years (range 44 to 88 years). The distance between alveolar border and inferior sinus margin at each tooth, the height of alveolar process and the thickness of cortical bone of the outer and inner table of alveolar process and the inferior wall of maxillary sinus were measured. Results and Conclusion: 1. The septum of inferior maxillary sinus were observe 28 sides (76.%) and located at the third molar (52.6%) and the second molar (26.3%). The deepest points of inferior border of maxillary sinus were located the first or second molar. The distance between alveolar margin and the deepest point of inferior maxillary sinus is $9.7{\pm}4.9mm$. 2. The length of the outer table of alveolar process were $4.9\sim28.2mm$ and the shortest point was between the first and the second molors. The thickness of them were $0.9\sim3.2mm$. The length of the inner table of alveolar process were $7.4\sim25.8mm$ and the shortest point was between the first and the second molars. The thickness of the were $0.9\sim4.6mm$. The results of this study are useful anatomical data for installing of maxillary implants.

CHANGES OF SENSORY AND SOMATOSENSORY EVOKED POTENTIALS FOLLOWING A NEEDLE INJURY ON THE INFERIOR ALVEOLAR NERVE IN RATS (백서 하치조 신경 손상에 따른 감각 유발전위와 체성감각 유발전위의 변화에 관한 연구)

  • Woo, Seung-Chel;Kim, Soo-Nam;Lee, Dong-Keun;Cheun, Sang-Woo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.4
    • /
    • pp.652-672
    • /
    • 1996
  • Dysfunction of the inferior alveolar nerve may result from trauma, diseases or iatrogenic injury. The development and refinement of an objective method to evaluate this clinical problem is highly desirable and needed, especially concerning for an increasing medico-legal issue. Evoked potential techniques have attracted considerable attention as a means of assessing the function and integrity of nerve pathways. The purpose of this study was to characterize the Sensory Evoked Potentials(SEPs) and Somatosensory Evoked Potentials(SSEPs) elicited by electrical stimulation of mental nerve. SEPs and SSEPs were measured and analyzed statistically before and after needle injury on the inferior alveolar nerve of Sprague-Dawalye rats. Measuring SEPs was more sensitive in evaluation of the recovery of sensory function from inferior alveolar nerve injury then measuring SSEPs but we measured SSEPs in the hope of providing a safe, simple and objective test to check oral and facial sensibility, which is acceptable to the patient. We stimulated mental nerve after needle injury on the inferior alveolar nerve and SEPS on the level of mandibular foramen and SSEPs on the level of cerebral cortex were recorded. Threshold, amplitude, and latency of both of SEPs and SSEPs were analyzed. The results were as follows ; 1. Threshold of SEPs and SSEPs were $184{\pm}14{\mu}A$ and $164{\pm}14{\mu}A$ respectively. 2 SEPs were composed of 2 waves, i.e., N1 N2 in which N1 was conducted by II fibers and N2 was conducted by III fibers. 3. SSEPS were composed of 5 waves, of which N1 and N2 shower statistically significant changes(p<0.01, unpaired t-test). 4. SEPs and SSEPs were observed to be abolished immediately after local anesthesia and recovered 30 minutes later. 5. SEPs were abolished immediately after injury. N1 of SSEPs was abolished immediately and amplitued of N2 was decreased($20.7{\pm}12.2%$) immediately after 23G needle injury, but N3, N4 and N5 did not change significantly. Recovery of waveform delayed 30 minutes in SEPs and 45 minutes in SSEPs. 6. The degree of decrease in amplitude of SEPs and SSEPs, after 30G needle injury was smaller than those with 23G. SEPs recorded on the level of mandibular foramen were though to be reliable and useful in the assessment of the function of the inferior alveolar nerve after injury. Amplitude of SSEPs reflected the function and integrity of nerve and measuring them provided a safe, simple and abjective test to check oral and facial sensibility. These results suggest that measuring SEPs and SSEPs are meaningful methods for objective assessment in the diagnosis of nerve injury. N1 and N2 of SSEPs can be useful parameters for the evaluation of the nerve function following a needle injury.

  • PDF

The effect of various thread designs on the initial stability of taper implants

  • Park, Ju-Hee;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.19-25
    • /
    • 2009
  • STATEMENT OF PROBLEM. Primary stability at the time of implant placement is related to the level of primary bone contact. The level of bone contact with implant is affected by thread design, surgical procedure and bone quality, etc. PURPOSE. The aim of this study was to compare the initial stability of the various taper implants according to the thread designs, half of which were engaged to inferior cortical wall of type IV bone(Group 1) and the rest of which were not engaged to inferior cortical wall(Group 2) by measuring the implant stability quotient(ISQ) and the removal torque value(RTV). MATERIAL AND METHODS. In this study, 6 different implant fixtures with 10 mm length were installed. In order to simulate the sinus inferior wall of type IV bone, one side cortical bone of swine rib was removed. 6 different implants were installed in the same bone block following manufacturer s recommended procedures. Total 10 bone blocks were made for each group. The height of Group 1 bone block was 10 mm for engagement and that of group 2 was 13 mm. The initial stability was measured with ISQ value using Osstell $mentor^{(R)}$ and with removal torque using MGT50 torque gauge. RESULTS. In this study, we found the following results. 1. In Group 1 with fixtures engaged to the inferior cortical wall, there was no significant difference in RTV and ISQ value among the 6 types of implants. 2. In Group 2 with fixtures not engaged to the inferior cortical wall, there was significant difference in RTV and ISQ value among the 6 types of implants(P < .05). 3. There was significant difference in RTV and ISQ value according to whether fixtures were engaged to the inferior cortical wall or not(P < .05). 4. Under-drilling made RTV and ISQ value increase significantly in the NT implants which had lower RTV and ISQ value in Group 2(P < .05). CONCLUSIONS. Without being engaged to the inferior cortical wall fixtures had initial stability affected by implant types. Also in poor quality bone, under-drilling improved initial stability.

Transient Visual Acuity Decrease after Inferior Alveolar Nerve Block Anesthesia (하악공 전달마취 후 발생한 일시적인 시력 저하)

  • Lim, Gee-Young;Yun, Hee-Jung;Pang, Nan-Sim;Jung, Bock-Young;Kim, Kee-Deog;Park, Won-Se
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.12 no.1
    • /
    • pp.39-43
    • /
    • 2012
  • One of the most common procedures in dentistry is the inferior alveolar nerve block anesthesia but visual problem can occur during this procedure. Transient visual acuity decrease after inferior alveolar nerve block anesthesia can result from unintended intravascular injection. In this case report, we present ocular complication that has rarely been reported. The understanding of anatomy related to this case is discussed with suggestions for proper management of the patients. The dental management for ocular complications includes a correct diagnosis, management by understanding of patient's anatomic variations. This will prevent intravascular injection.

Superior Orbital Fissure Syndrome after Repair of Blow Out Fracture (안와골절 정복술 후 발생한 상안와열증후군의 치험례)

  • Lee, Young-Bae;Kim, Peter Chan-Woo;Park, Dae-Hwan
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.879-882
    • /
    • 2011
  • Purpose: Superior orbital fissure syndrome is a rare neurological complex. Superior orbital fissure syndrome may result from a variety of inflammatory, infectious, neoplastic, iatrogenic, traumatic, vascular cause. The author report a patient who suffered from superior orbital fissure syndrome after inferior orbital wall reduction. Methods: A 26-year-old female suffered from inferior orbital wall fracture with inferior gaze limitation and orbital soft tissue herniation. On posttrauma 10 day, inferior orbital wall was reduced using endoscope and porous polyethylene ($Medpor^{(R)}$) was inserted. On immediate postoperation, she reported that extraocular movement was limited in almost any directions. She underwent exploration surgery to release the presence of extraocular muscle impingement. But, there was no observation of extraocular muscle impingement. On postoperative one day, high-dose steroid therapy was started to release superior orbital fissure syndrome which was defined in postoperative computed tomography. Results: After one month of high-dose steroid therapy, extraocular movement limitations improved progressively in all directions. In four months, extraocular movement recovered completely. Conclusion: Superior orbital fissure syndrome may occur after surgical procedure of orbital wall reduction. Prompt diagnosis and treatment with mega-dose corticosteroid is an effective option for avoiding disaster from compressive syndrome.