• Title/Summary/Keyword: indoor cell

Search Result 143, Processing Time 0.025 seconds

Implementation of Popular Radon Detector Using Pin Photodiode (핀 포토다이오드를 이용한 보급형 라돈 검출기의 구현)

  • Yun, Sung-Ha;Kim, Jae-Hak;Kim, Gyu-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.99-106
    • /
    • 2016
  • When radon is staying at alveoli and bronchial tubes, the collapse of radon creates progeny nuclides (alpha ray, beta ray, gamma ray, etc.). They emit radiation causing a mutation in the chromosome of the cell, resulting in lung cancer. In other words, the main cause of lung cancer is radiation emitting as the result of radon collapse rather than radon gas. The 82% of radiation exposed to people is the natural radiation. Most of the natural radiation is radon. If we properly control the concentration of radon indoors, the probability of occurrence of lung cancer could be decreases to be 70%. Until now, to measure the indoor radon concentration, imported radon sensors are needed. So, DB construction of indoor radon emission and popular radon measuring apparatus should be developed. In this paper, we propose the radon detecting method using PIN photodiode. Also, we confirmed the PIN photodiode could be used as radon sensor module through some experimental studies.

Development of a Set of an Experimental Equipment of Westerly Wave for High School (고등학교에 적합한 편서풍 파동 실험장치 개발)

  • Lee, Soon-Hwan;Park, Gwang-Soon;Kim, Hee-Soo
    • Journal of the Korean earth science society
    • /
    • v.27 no.2
    • /
    • pp.177-187
    • /
    • 2006
  • Due to a lack of reproducibility and visibility of the conventional equipment for westerly wave simulation, it is difficult to have indoor experiments at high school that show the stream of Hadley cell. A modified improvement of the old one improves the problem. The side wall and bottom of the new equipment is made by copper and acrylic resin, respectively, in order to clarify the difference between the water temperature inside and outside of the water tank. The equipment also has a high quality digital record for generating exact analysis of the results. And we also carried out several experiments that relate theoretical and experimental aspection of westerly wave. Temperature Detected Sheet (TDS) in flow visualization unit provides not only visual information of liquid flow, but also clear understanding of the relation between upper and lower wind flow structure. And the liquid stream simulated in indoor experiment using proposed equipment is commensurate with westerly wave in real atmosphere. The efficiency of educational properties of the proposed equipment is verified indirectly by Likert Scales survey of high school teachers.

Recent Progress in Air Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2007 (설비공학 분야의 최근 연구 동향 : 2007년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Shin, Dong-Sin;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.844-861
    • /
    • 2008
  • The papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during the year of 2007 have been reviewed. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro nano fluid, micropump and fuel cell. Traditional CFD was still popular and widely used in research and development. Studies about fans and pumps were performed in the field of fluid machinery. Characteristics of flow and fin shape optimization are studied in the field of piping system. (2) The research works on heat transfer have been reviewed in the field of heat transfer characteristics, heat exchangers, and desiccant cooling systems. The research on heat transfer characteristics includes thermal transport in pulse tubes, high temperature superconductors, ground heat exchangers, fuel cell stacks and ice slurry systems. For the heat 'exchangers, the research on pin-tube heat exchanger, plate heat exchanger, condensers and gas coolers has been cordially implemented. The research works on heat transfer augmenting tubes have been also reported. For the desiccant cooling systems, the studies on the design and operating conditions for desiccant rotors as well as performance index are noticeable. (3) In the field of refrigeration, many papers were presented on the air conditioning system using CO2 as a refrigerant. The issues on the two-stage compression, the oil selection, and the appropriate oil charge were treated. The subjects of alternative refrigerants were also studied steadily. Hydrocarbons, DME and their mixtures were considered and various heat transfer correlations were proposed. (4) Research papers have been reviewed in the field of building facilities by grouping into the researches on heat and cold sources, air conditioning and air cleaning, ventilation and fire research including tunnel ventilation, flow control of piping system, and sound research with drain system. Main focuses have been addressed to the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies were mostly focused on analyzing the indoor environment in various spaces like cars, old tombs, machine rooms, and etc. in an architectural environmental field. Moreover, subjects of various fields such as the evaluation of noise, thermal environment, indoor air quality and development of energy analysis program were researched by various methods of survey, simulation, and field experiment.

Treatment of BG-1 Ovarian Cancer Cells Expressing Estrogen Receptors with Lambda-cyhalothrin and Cypermethrin Caused a Partial Estrogenicity Via an Estrogen Receptor-dependent Pathway

  • Kim, Cho-Won;Go, Ryeo-Eun;Choi, Kyung-Chul
    • Toxicological Research
    • /
    • v.31 no.4
    • /
    • pp.331-337
    • /
    • 2015
  • Synthetic pyrethroids (SPs) are the most common pesticides which are recently used for indoor pest control. The widespread use of SPs has resulted in the increased exposure to wild animals and humans. Recently, some SPs are suspected as endocrine disrupting chemicals (EDCs) and have been assessed for their potential estrogenicity by adopting various analyzing assays. In this study, we examined the estrogenic effects of lambda-cyhalothrin (LC) and cypermethrin (CP), the most commonly used pesticides in Korea, using BG-1 ovarian cancer cells expressing estrogen receptors (ERs). To evaluate the estrogenic activities of two SPs, LC and CP, we employed MTT assay and reverse-transcription polymerase chain reaction (RT-PCR) in LC or CP treated BG-1 ovarian cancer cells. In MTT assay, LC ($10^{-6}M$) and CP ($10^{-5}M$) significantly induced the growth of BG-1 cancer cells. LC or CP-induced cell growth was antagonized by addition of ICI 182,720 ($10^{-8}M$), an ER antagonist, suggesting that this effect appears to be mediated by an ER-dependent manner. Moreover, RT-PCR results showed that transcriptional level of cyclin D1, a cell cycle-regulating gene, was significantly up-regulated by LC and CP, while these effects were reversed by co-treatment of ICI 182,780. However, p21, a cyclin D-ckd-4 inhibitor gene, was not altered by LC or CP. Moreover, $ER{\alpha}$ expression was not significantly changed by LC and CP, while down-regulated by E2. Finally, in xenografted mouse model transplanted with human BG-1 ovarian cancer cells, E2 significantly increased the tumor volume compare to a negative control, but LC did not. Taken together, these results suggest that LC and CP may possess estrogenic potentials by stimulating the growth of BG-1 ovarian cancer cells via partially ER signaling pathway associated with cell cycle as did E2, but this estrogenic effect was not found in in vivo mouse model.

Application of Field and Laboratory Emission Cell (FLEC) to Determine Formaldehyde and VOCs Emissions from Wood-Based Composites

  • Kim, Sumin;Kim, Jin-A;Kim, Hyun-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.24-37
    • /
    • 2007
  • The Korean Ministry of Environment started controlling indoor air quality (IAQ) in 2004 through the introduction of a law regulating the use of pollutant emitting building materials. The use of materials with formaldehyde emission levels above $1.25 mg/m^2{\cdot}h$ (JIS A 1901, small chamber method) has been prohibited. This level is equivalent to the $E_2$ grade ($>5.0mg/{\ell}$) of the desiccator method (JIS A 1460). However, the $20{\ell}$ small chamber method requires a 7-day test time to obtain the formaldehyde and volatile organic compound (VOC) emission results from solid building interior materials. As a approach to significantly reduce the test time, the field and laboratory emission cell (FLEC) has been proposed in Europe with a total test time less than one hour. This paper assesses the reproducibility of testing formaldehyde and TVOC emissions from wood-based composites such as medium density fiberboard (MDF), laminate flooring, and engineered flooring using three methods: desiccator, perforator and FLEC. According to the desiccator and perforator standards, the formaldehyde emission level of each flooring was ${\le}E_1$ grade. The formaldehyde emission of MDF was $3.48 mg/{\ell}$ by the desiccator method and 8.57 g/100 g by the perforator method. To determine the formaldehyde emission, the peak areas of each wood-based composite were calculated from aldehyde chromatograms obtained using the FLEC method. Formaldehyde, acetaldehyde, propionaldehyde, butyraldehyde and benzaldehyde were detected as aldehyde compounds. The experimental results indicated that MDF emitted chloroform, benzene, trichloroethylene, toluene, ethylbenzene, m,p-xy-lene, styrene, and o-xylene. MDF emitted significantly greater amounts of VOCs than the floorings did.

Heating Power Consumption Comparison Study Between Static Insulation and Dynamic Insulation at KIER Twin Test Cell (동적 단열재를 적용한 건물에서의 에너지소비량 비교 분석)

  • Kang, Eun-Chul;Park, Yong-Dai;Lee, Euy-Joon;Yun, Tae-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.919-924
    • /
    • 2008
  • Power consumption in the building thermal load could be the sum of the building fabric conduction load, building ventilation convection load and other such as radiation loss load. Dynamic Breathing Building (DBB) is the state-of-the-art to improve the wall insulation and indoor air quality(IAQ) performance as making air flow through the wall. This heat recovery type DBB contributes the power consumption saving due to the improved dynamic U-value. KIER twin test cell with static insulation(SI) and dynamic insulation(DI) at KIER was developed to test building power consumption at the real outside conditions. Then, the actual results were compared with the theory to predict the power consumption at the KIER twin test cell and introduced the building new radiation loss factor $\alpha$ to explain the difference between the both the theory and the actual case. As the results, the power consumption at the breathing DI wall building could saved 10.8% at the 2ACH(Air change per hour) compared with conventional insulation. The building radiation loss factor $\alpha$ for this test condition to calibrate the actual test was 0.55 in the test condition.

  • PDF

A Study on the Estimation of Average Service Life for New Technology Products-in Case of Solor-cell (신기술 제품의 ASL 추정-솔라셀 사례 중심으로)

  • Cho, Jin-Hyung;Lee, S.J.;Oh, H.S.;Baek, S.S.;Kim, O.J.;Kim, B.K.;Jeong, K.S.;Park, S.H.;Kwon, D.C.;Ko, J.H.;Ryu, J.H.;Shim, S.C.
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.4
    • /
    • pp.106-115
    • /
    • 2014
  • Until now, because a new product (or facility) launched in market has been retired from one year of age, we can have had ASL by stub-curve method by Iowa curve. Recently, many innovative products with important role in market like display and solar-cell etc. are more durable and, what are better, they have the constant variance in ASL because of their good quality. Of course, there are some ones like smart mobile phone with relatively big dispersion in ASL. Estimating ASL of products like display and solar-cell etc., the new approach is needed. In this paper a new method applied traditional Iowa curve with accelerated reliability test (indoor/outdoor) etc. is proposed.

Urban Design cases study analysis using solar cell : Focusing on the use CIGS Thin Film Solar cell (태양전지를 활용한 도시디자인 사례분석 연구 : CIGS 박막 태양전지의 활용을 중심으로)

  • Park, Ji-Hoon;Nam, Won-Suk;Jang, Jung-Sik
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.3
    • /
    • pp.163-170
    • /
    • 2020
  • This research was to understand the current situation and trends of urban design using rapidly growing solar cells at home and abroad, and to understand the positive aspects and implications of urban design proposals using CIGS thin film solar cells, a research project to be conducted based on case analysis. The research method was conducted through a literature study and the case was investigated and analyzed after identifying the present situation and trends of urban design using solar cells from home and abroad. As a result, it was confirmed that urban design using solar cells was steadily increasing, and through visual changes such as harmony with the surrounding environment, indoor and outdoor visualization, and the use of color, urban aesthetic beauty creation was positive. Based on these implications, we will present the expected effects of CIGS thin film solar cells being utilized in urban design, and confirm the direction and significance of the urban design proposal using CIGS thin film solar cells in the future.

A Study on the Performance Characteristics of a Heat Pump System using Stack Wast Heat in Fuel Cell Vehicles (스택 폐열을 이용한 연료전지 자동차용 열펌프 시스템의 성능 특성에 관한 연구)

  • Jeon, Byungyong;Ko, Wonbin;Park, Youn Cheol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.8
    • /
    • pp.325-330
    • /
    • 2016
  • This study was conducted to develop a heating system for a fuel cell-driven electric vehicle. The system consists of a compressor, an expansion device and three heat exchangers. A conventional air source heat exchanger is used as primary heat exchanger of the system, and an additional water source heat exchanger is used as a pre-heater to supply heat to the upstream air of the primary heat exchanger. On the other hand, the third heat exchanger consists of a water-to-refrigerant heat exchanger. The heat source of the pre-heater and the water-refrigerant heat exchanger is the waste heat from the fuel cell's stack. In the experiment, the indoor and the outdoor air temperature were fixed, and the compressor speed, EEV opening and waste heat temperature were varied. The results indicate that the $COP_h$ of the proposed system is 3.01 when the system is operating at a 1,200 rpm compressor speed, 50% EEV opening, and $50^{\circ}C$ waste heat source temperature in air pre-heater operation. However, when the system uses a water-refrigerant heat exchanger, the $COP_h$ increases to up to 9.42 at the same compressor speed and waste heat source temperature with 75% EEV openings.

An Assessment of Environmental Characteristics Associated with the Level of Endotoxin Concentration in Hospital Lobbies (일부 종합 병원 로비의 공기 중 엔도톡신 농도에 미치는 환경 요인 평가)

  • Lee, Kyeong-Min;Yeom, Jeongkwan;Lee, Wonjae;Ryu, Seung-Hun;Park, Dongjin;Park, Dong-Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.3
    • /
    • pp.310-320
    • /
    • 2014
  • Backgrounds: Endotoxin, which found in the outer membrane of the gram-negative bacteria cell wall, makes up almost all of the lipopolysaccharide(LPS). When people are exposed to endotoxin,it can result in diverse health effects such as an airway irritation and inflammation, fever, malaise, bronchitis, allergic asthma, toxic pneumonitis, hypersensitivity lung disease. Cases among the elderly, children or pregnant can occur more frequently than a healthy adult if they are repeatedly exposed to the existing endotoxin. Therefore, we investigated and assessed the environmental characteristics associated with the airborne endotoxin concentration level in six hospital lobbies. Method: Endotoxin from indoor air in six hospital lobbies was measured by an area sampling method and analyzed according to American Society for Testing and Materials International(ASTM international) E2144-01. Total suspended particulate(TSP), carbon dioxide($CO_2$), temperature and humidity were also measured by using direct reading measurements or airborne sampling equipment at the same time. Environmental characteristics were appropriately divided into two or three groups for a statistics analysis. One-way analysis variable(one-way ANOVA) was used to examine a difference of the endotoxin concentration, depending on the environmental characteristics. In addition, only variables with p-value(p<0.25) were eventually designed to the best model by using multiple regression analysis. Results: The correlation analysis result indicated that TSP(p=0.003) and $CO_2$(p<0.0001) levels were significantly associated with endotoxin concentration levels. In contrast, temperature(p<0.068) and humidity(p<0.365) were not associated with endotoxin concentration. Levels of endotoxin concentration were statistically different among the environmental characteristics of Service time(p=0.01), Establishment of hospital(p<0.001), Scale of hospital(p=0.01), Day average people using hospital(p=0.03), Cleaning time of lobby(p=0.05), Season(p<0.001), and Cleaning of ventilation system(p<0.001) according to ANOVA. Finally, the best model(Adjusted R-square=72%) that we designed through a multiple regression test included environmental characteristics related to Service time, Area of lobby, Season, Cleaning of ventilation system, and Temperature. Conclusions: According to this study, our result showed a normal level of endotoxin concentration in the hospital lobbies and found environmental management methods to reduce the level of endotoxin concentration to a minimum. Consequently, this study recognized to be requirement for the management of ventilation systems and an indoor temperature in order to reduce the level of endotoxin concentration in the hospital lobbies.