• Title/Summary/Keyword: indoor air pollutant

Search Result 125, Processing Time 0.03 seconds

Ozone Response on Indoor Landscape Plants (실내식물의 오존 반응)

  • 허정희;방광자;설종호
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.28 no.5
    • /
    • pp.87-92
    • /
    • 2000
  • The purpose of this study is to investigate Ozone which we have to contact in our daily lives. Recently Ozone becomes a serious pollutant in the inside and outside. To select th indicator plants or the purifier plants for air pollution caused by ozone, this stud has been conducted with interior landscape plant of 10 species. The results are as follows; 1) The visible demage by Ozone was firstly observed on Viburnum awabuki among 10 species, and it occurred after the lapse of 10, 8 and 4 hours on 0.5, 1.0 and 2.0 ppm ozone treatment, respectively. The first symptom of visible demage appeared on chlorosis or blotting of leaves, then progressed on necrosis of leaves. 2) On the other hand, Litsea japonica and Ardisia japonica were so resistant against Ozone fumigation that they were not demage independently of Ozone concentration till the lapse of 60 hours. 3) Chlorophyll contents were decreased by the increased Ozone concentration. At this time, grana destruction was observed. The most sensitive plant to ozone was Viburnum awabuki, and we suggest that Viburnum awabuki would be possible one to use for the indicator plant. The most resistance plant to Ozone was Litsea japonic and Ardisia japonica, we suggest that Litsea japonica and Ardisia japonica would be possible to use for the purifier plant for Ozone pollution.

  • PDF

Health risk assessment by CRPS and the numerical model for toluene in residential buildings

  • Choi, Haneul;Kim, Hyungkeun;Kim, Taeyeon
    • KIEAE Journal
    • /
    • v.17 no.5
    • /
    • pp.33-41
    • /
    • 2017
  • Purpose: Indoor air quality in residential buildings needs to be evaluated over the long term. In previous research, there has been an attempt to perform the health risk assessment of pollutants by using numerical models as a method of long-term evaluation. However, the numerical model of this precedent study has limitations that do not reflect the actual concentration distribution. Therefore, this study introduces the CRPS index, constructs a numerical model that can reflect the concentration distribution, and then presents a more accurate health risk assessment method using it. At this time, the pollutants are toluene, which is a typical material released from building materials. Method: CRPS index was applied to existing numerical model to reflect concentration distribution. This was used to calculate concentrations at adult breathing area and to use them for exposure assessment in a health risk assessment. After that, we entered adult data and conducted a health risk assessment of toluene. Results: The non-carcinogenic risk of toluene was calculated to be 0.0060. This is 5% smaller than the existing numerical model, meaning that it is more accurate to predict the pollutant risks. This value is also lower than the US EPA reference value of 1. Therefore, under the conditions of this study, long-term exposure of adults to toluene has no impact on health.

Investigation into Air Pollution in Car Shipping Workshop in Pyeongtaek Port (자동차 선적작업장의 공기오염 실태조사)

  • Kim, Ji-Ho;Won, Jong-Uk;Kim, Chi-Nyon;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.1
    • /
    • pp.44-53
    • /
    • 2006
  • This study purposed to investigate air pollution in car shipping yards and, for this purpose, we selected an outdoor open-air yard and an indoor ramp into the ship and measured the concentrations of sulfur dioxide, nitrogen dioxide, carbon monoxide, PM10, PM2.5 and heavy metals in the air. The results of this study are as follows. No significant difference was observed in temperature and humidity between the outdoor and indoor workshop, and the average air flow was 0.52 m/s in the indoor workshop, which is higher than 0.19 m/s in the outdoor workshop(p<0.01). The average concentrations of sulfur dioxide, nitrogen dioxide, carbon monoxide, PM10 and PM2.5 according to workplace were 0.03 ppm(${\pm}0.01$), 0.03 ppm(${\pm}0.01$), 0.46 ppm(${\pm}0.22$), $39.44{\mu}g/m^3$(${\pm}2.45$) and $5.45{\mu}g/m^3$(${\pm}1.15$) respectively in the outdoor workshop, and 0.15 ppm(${\pm}0.05$), 0.22 ppm(${\pm}0.06$), 8.85 ppm(${\pm}3.35$), $236.39{\mu}g/m^3$(${\pm}58.21$) and $152.43{\mu}g/m^3$(${\pm}35.42$) respectively in the indoor workshop. Thus, the concentrations of gaseous substances in the indoor workshop were 4.9-19.2 times higher than those in the outdoor workshop, and the concentrations of fine dusts were 5.9-27.9 times higher(p<0.01). In addition, according to the result of investigating pollutant concentrations according to displacement and the number of car loaded when shipping gasoline cars into the ship, no significant relation between the number of cars loaded and pollutants was observed in shipping passenger cars, but the concentrations of nitrogen dioxide and carbon monoxide got somewhat higher with the increase of the number of cars loaded(p<0.05). In addition, the concentrations of nitrogen dioxide, carbon monoxide, PM10 and PM2.5 in the air were significantly higher when shipping recreational vehicles, the displacement of which is larger than passenger cars, than when shipping passenger cars(p<0.01). On the other hand, the average heavy metal concentrations of the air in indoor workshop were: lead $-0.05{\mu}g/m^3$(${\pm}0.10$); chromium $-0.90{\mu}g/m^3$(${\pm}0.18$); zinc $-0.38{\mu}g/m^3$(${\pm}0.24$); copper $-0.18{\mu}g/m^3$(${\pm}0.22$); and manganese and cadmium not detected. In addition, the complaining rates of 'asthma,' a major symptom of chronic respiratory diseases, were 18.5% and 22.5% respectively in indoor workers and outdoor workers. Thus the rate was somewhat higher in indoor workers but the difference was not statistically significant. The complaining rates of 'chronic cough' and 'chronic phlegm' were very low and little different between indoor and outdoor workers. The results of this study show that the reason for the higher air pollution in indoor than in outdoor workshop is incomplete combustion of fuel due to sudden start and over-speed when cars are driven inside the ship. In order to prevent high air pollution, efficient management measures should be taken including the observance of the optimal speed, the improvement of old ships and the installation of efficient ventilation system.

A Study on the Air Flow Characteristics in an Apartment Complex and Ventilation Performance of an Individual Unit for Improving IAQ (주동형태 변화에 따른 아파트 단지내 기류분석 및 단위주호의 환기성능에 관한 연구)

  • Lee, Jung-Hyun;Lee, Seung-Hee;Kim, Taeyeon
    • KIEAE Journal
    • /
    • v.5 no.3
    • /
    • pp.11-16
    • /
    • 2005
  • The recent trends of high-density and high-rise in apartment housing have caused the problems of decrease in ventilation rates and increase of indoor pollutant contaminants. SHS(Sick House Syndrome) has now become a major issue and threats the health of residents. To solve these indoor air problems, increase in ventilation rate is considered as one of the most efficient approach. Thus, the recent housing development is pursuing improvement in the site design and the layout of apartment building blocks to promote natural ventilation is now investigated as one of the fundamental solutions. This study was focused on the air flow characteristics of outdoor environment in an apartment complex to keep the pollutants out of the site. Age of air and pressure difference have been used as indices of the outdoor air quality. Four different types of apartment building layouts have been analyzed by CFD simulation. This study again selected a real apartment housing complex as a case study model. By analyzing the pressure differences between the front and rear of an apartment building block, the ventilation performance in each individual unit was evaluated, and its impact on ventilation performance is investigated by analyzing the stagnant air around the apartment building blocks. During this process, existing patterns of apartment housing layout have been evaluated, and the most appropriate site layout has been chosen to analyze the outdoor airflow patterns. Based on the analysis of airflow patterns of site layout, the possibilities of improving ventilation performance of an individual apartment housing is proposed.

A Study of Development of Evaluation on Source Strength and Deposition Constant of VOCs (주택 실내환경 VOCs의 발생량 및 감소량에 관한 연구)

  • Jung, Soon-Won;Yang, Won-Ho;Kim, Dae-Sun;Song, Mi-Ra;Son, Bu-Soon
    • Journal of Environmental Science International
    • /
    • v.16 no.9
    • /
    • pp.1019-1026
    • /
    • 2007
  • This study was performed in 30 selected apartments in Seoul, Asan and Daegu area which were constructed within 4 years and over 4 years, to measure the concentration of VOCs(benzene, toluene, xylene) from July, 2004 to September. Mean ratios of indoor to outdoor VOCs concentrations in the construction under 4 years were higher in 1 than average, I/O ratio of over 4 years were lower in 1. This was considered that the VOCs density influences indoor pollutant. For the indoor air quality estimation, the deposition constant and the source strength factor of toluene were $1.49{\pm}2.05\;hr^{-1}\;and\;36.95{\pm}52.26\;ppb/h$, respectively.

A Study on the Control Performance for Hazardous Gases by Surface Discharge induced Plasma Chemical Process (연면방전의 플라즈마 화학처리에 의한 유해가스제어 성능에 관한 연구)

  • 이주상;김신도;김광영;김종호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.2
    • /
    • pp.185-190
    • /
    • 1995
  • Recently, because of the worse of the air pollution, the excessive airtught of building and the inferiority of air conditioning system, the development of high efficiency air purification technology was enlarged to the environmental improvement of an indoor or a harmful working condition. The air purification technology has used chemical filters or charcoal filters or charcoal to remove hazardouse gaseous pollutants (SO$_{x}$, NO$_{x}$, NH$_{3}$, etc.) by air pollutant control technology, but they have many problems of high pressure loss, short life, wide space possession, and treatment of secondary wastes. For these reason, the object of reasearch shall be hazardous gaseous pollutants removal by the surface discharge induced plasma chemical process that is A.C. discharge of multistreams applied A.C. voltage and frequency between plane induced eletrode and line discharge eletrode of tungsten, platinum or titanium with a high purified alumina sheet having a film-like plane. As a result, the control performance for hazardous gaseous pollutants showed very high efficiency in the normal temperature and pressure. Also, after comtact oxidation decomposition of harmful gaseous pollutants, the remainded ozone concentration was found much lower than that of ACGIH or air pollution criteria in Korea.rea.

  • PDF

A Study on the Performance of a Short Term Ozone Passive Sampler in Experimental Chamber (단기 측정용 오존 간이 측정기의 실험 챔버 내에서 성능에 관한 연구)

  • Jeong, Sang-Jin
    • Journal of Environmental Science International
    • /
    • v.16 no.8
    • /
    • pp.1001-1009
    • /
    • 2007
  • Passive sampler is a simple and cost-effective measuring equipment for ambient and indoor air pollution. We studied the performance of a short term (1 hour mean concentration) ozone passive sampler which was coated with a colorant (indigo carmine) to a filter substrate. Acetone and sulfamic acid added ozone passive sampler was investigated to measure short term mean ozone concentration. Ozone response and interference of criteria air pollutant($SO_2,\;NO_2$, CO) on a short term ozone passive sampler was tested through experimental chamber. The results show sulfamic acid added passive ozone sampler have good response in ozone exposure. Interference of $NO_2$ gas is larger than other two criteria gases.

Economical Ventilation Effectiveness to Reduce Hazardous Chemical Emissions for a Nail-Salon Worker

  • KWON, Woo-Taeg;JUNG, Min-Jae;LEE, Woo-Sik;KWON, Lee-Seung;SO, Young-Jin
    • Journal of Distribution Science
    • /
    • v.17 no.7
    • /
    • pp.65-76
    • /
    • 2019
  • Purpose - The purpose of this study is to investigate economical ventilation effectiveness to reduce hazardous materials exposure and damage of workers by analyzing exposure amount of noxious substances under various ventilation conditions of nail salon for indoor environments. Research design, data, and methodology - This study was carried out with cooperation of Nail shop located in SeongNam city to involve an analysis of the environmental impact indoor air quality, pollutant exposure and economical cost-effectiveness in the nail workplace. The hazardous substances were PM-10(Particulate Matter-10㎛), VOCs(Volatile Organic Compounds) and Formaldehyde, which are the major materials of nail workplace. Results - PM-10 is reduced by about 60% with air cleaner, forced artificial ventilation by 32%, and natural ventilation by about 12%. TVOCs and Formaldehyde showed similar efficiency (80~100%) after natural ventilation and ventilation after 60 minutes. The removal efficiencies of VOCs and formaldehyde were similar to those of natural ventilation and mechanical ventilation system. However, in case of dust, natural ventilation was reduced by artificial ventilation system due to inflow of external dust during natural ventilation. Conclusions - If the pollution degree of outdoor air is not high, air volume is high, and natural ventilation is performed when the air conditioning and heating system is not operated. Even at the end of the work, it keeps operating for 60 minutes to remove the pollutants generated. Results of this analysis demonstrated that the worker environment can be improved by adopting institutional legislation and guidelines for ventilation.

Indoor and Outdoor $NO_2$ Concentration of Shoe-stall near Busy Road and $NO_2$ Decay by Distance from Roadside - Comparative Study between Seoul and Asan - (도로변 구두수선대 실내.외의 이산화질소 농도 및 거리에 따른 이산화질소 감소 - 서울시와 아산시의 비교 연구 -)

  • 양원호;손부순;박종안;김종오
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.2
    • /
    • pp.85-91
    • /
    • 2002
  • Workers who work at indoor and outdoor environment near busy road are suspected to be exposed to high-elevated air pollutant levels during working hours. This study evaluated the working-time nitrogen dioxide ($NO_2$) exposure for workers (repairmen and polishers) of shoe-stalls. Since shoe-stalls have particularly been located near busy road in Korea, workers might be high exposure to $NO_2$ from traffic exhaust as well as indoor sources of shoe-stall such as portable gas range (butane gas) during working hours. In this study, we measured the indoor and outdoor $NO_2$ concentrations of shoe-stalls. Simultaneously, outdoor $NO_2$ concentrations of building through sidewalk from shoe-stall were measured. High $NO_2$ exposure for workers of shoe-stalls was considered to be inflow of outdoor source of exhausted emission from vehicles and indoor source from usage of gas range to polish the shoe. Indoor/outdoor $NO_2$ concentration ratio ($0.94{\pm}0.22$) in Seoul was higher than that ($1.06{\pm}0.34$) in Asan, because ambient $NO_2$ level was high in Seoul and usage of gas range was prevalent in Asan. According to $NO_2$ concentrations by distance from roadside to building through sidewalk, $NO_2$ concentrations showed the decreased trend with distance. The results of this study can be utilized by municipal authorities in urban planning for evaluating effects of future traffic planning and land use.

Assessment of Exposure to and Risk of Formaldehyde and Particulate Matter (PM10 and PM2.5) by Time Activity Applying Real-Time Indoor and Outdoor Monitoring (실내·외 실시간 모니터링을 활용한 폼알데하이드 및 미세먼지(PM10, PM2.5)의 거주시간별 노출 및 위해도 평가)

  • Yoon, Danki;Namgoung, Sunju;Kong, Hyekwan;Hong, Hyungjin;Lim, Huibeen;Park, Sihyun;Lee, Hyewon;Lee, Jungsub;Lee, Cheolmin
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.6
    • /
    • pp.646-657
    • /
    • 2019
  • Objectives: The purpose of this study was to suggest methods to investigate continuous monitoring of concentration levels and assess the exposure of individuals considering the actual time activity of residents for formaldehyde and particulate matter (PM10, PM2.5) in the indoor and outdoor air of a house, assess the health risks of children and adults based on the results of the exposure assessment, and provide basic data on studies for assessing exposure and health risks in Korea in the future. Methods: The concentration levels of formaldehyde and particulate matter were measured in a family home in Gyeonggi-do Province from April 25 to July 31, 2019, using electrochemical sensors (formaldehyde) and light scattering sensors (PM10, PM2.5). Risk assessment by the duration of exposure by time activity was performed by dividing between weekdays and weekends, and indoors and outdoors. Results: The greatest level of carcinogenic risk from inhaling formaldehyde was indoors during the weekdays for both children and adults. For children, the risk was at 7.5 per approximately 10,000 people, and for adults, the risk was at 4.1 per approximately 10,000 people. PM10 and PM2.5 also showed the greatest values indoors during the weekdays, with children at 1.7 people and 1.4 per approximately 100 people, respectively, and adults at 8.2 per approximately 1,000 and 1.8 per approximately 100 people, respectively. Conclusions: The risks of formaldehyde, PM10 and PM2.5 were shown to be high indoors. Therefore, consideration of exposure assesment for each indoor pollutant and management of indoor air quality is necessary.