DOI QR코드

DOI QR Code

A Study on the Performance of a Short Term Ozone Passive Sampler in Experimental Chamber

단기 측정용 오존 간이 측정기의 실험 챔버 내에서 성능에 관한 연구

  • 정상진 (경기대학교 공과대학 환경공학)
  • Published : 2007.08.31

Abstract

Passive sampler is a simple and cost-effective measuring equipment for ambient and indoor air pollution. We studied the performance of a short term (1 hour mean concentration) ozone passive sampler which was coated with a colorant (indigo carmine) to a filter substrate. Acetone and sulfamic acid added ozone passive sampler was investigated to measure short term mean ozone concentration. Ozone response and interference of criteria air pollutant($SO_2,\;NO_2$, CO) on a short term ozone passive sampler was tested through experimental chamber. The results show sulfamic acid added passive ozone sampler have good response in ozone exposure. Interference of $NO_2$ gas is larger than other two criteria gases.

Keywords

References

  1. Krupa S. V., Legge A. H., 2000, Passive sampling of ambient, gaseous air pollutants: an assessment from an ecological perspective, Environmental Pollution, 107, 31-45 https://doi.org/10.1016/S0269-7491(99)00154-2
  2. 천만영, 강공언, 김희강, 1992, $NO_{2}$ 간이포집기의 정도에 관한 연구, 한국대기보전학회지, 8(1), 93-99
  3. 우정현, 김선태, 김정욱, 1997, 수동측정기에 의한 대기오염 자동측정망의 지역대표성 조사 및 보완방법에 대한 기초연구, 한국대기보전학회지, 13(6), 415-426
  4. 양원호, 이기영, 백도명, 2000, 실내 및 실외공기 중 이산화질소 개인 노출량 측정을 위한 수동식 시료채취기의 성능평가, 한국대기환경학회지, 16(6), 625-631
  5. Kim S. T., Kim H. S., 2002, The Nationwide $NO_{2}$ Monitering with Passive Sampler in Korea, J. Korean Society for Armospheric Environment, 18(E2), 69-77
  6. Kim S. T., Maeda Y., 2003, The Study on the effects of air pollution on the material damages in northeast Asia, J. Korean Society for Armospheric Environment, 19(E2), 51-61
  7. 정상진, 장재철, 2004, Methyl Yellow와 Methyl Orange 지시약을 이용한 실내공기중의 포름알데히드 간이측정기에 대한 연구, 한국대기환경학회지, 20(6), 793-801
  8. 엄봉빈, 정의석, 김선태, 2004, 형광물질을 이용한 대기중 오존 Passive sampler의 개발, 한국대기환경학회지, 20(4), 483-491
  9. 최성득, 장윤석, 2005, Passive Air Sampler를 이용한 잔류성 유기오염물질의 대기 모니터링, 한국대기환경학회지, 21(5), 481-494
  10. 김선태, 임봉빈, 정재호, 2005, 4-Amino-3- hydrazino-5-mercapto-1,2,4-triazole을 이용한 실내 포름알데히드 측정용 passive sampler 개발, 한국대기환경학회지, 21(6), 593-603
  11. 김선규, 임봉빈, 정의석, 김선태, 2006, 대기중 이산화질소의 단기 측정을 위한 뱃지형 passive sampler의 개발 및 평가, 한국대기환경학회지, 22(1), 117-126
  12. 정상진, 2002, 오존 간이측정기에 대한 연구(I)- 필터의 민감도, 한국대기환경학회지, 18(5), 383-391
  13. Kizil M. S., Peterson J., English W., 2001, The effect of coal particle size on colorimetric analysis of roadway dust, J. of Loss Prevention in the process industries, 14, 387-394 https://doi.org/10.1016/S0950-4230(01)00013-4
  14. Shan Y., Normand N. D., Peleg M., 1997, Estimation of the surface concentration of adhered particles by color imaging, Powder Technology, 92, 147-153 https://doi.org/10.1016/S0032-5910(97)03232-4
  15. Grojean D., Hisham M. W., 1992, A passive sampler for atmospheric ozone, Journal of Air & Waste Management Association, 42, 169-173 https://doi.org/10.1080/10473289.1992.10466980
  16. 장재철, 2004, 색도법을 이용한 대기중 HCHO 측정법에 대한 연구, 석사학위논문, 환경공학과, 경기대학교. 수원
  17. 정상진, 양희준, 2006, 오존간이측정기에 대한 연구(II)-간섭현상 및 현장 적용성, 한국대기환경학회지, 22(6), 904-911
  18. 정상진, 2001, 오존 간이측정기의 챔버내 성능평가에 관한 연구, 경기대학교 산업기술종합연구소 논문집 , 22, 47-56
  19. 모세영, 1996, 대기오염공학실험, 동화기술, 426pp
  20. 동화기술편집부, 2005, 대기오염.소음.진동 공정시험방법, 동화기술, 894pp