• Title/Summary/Keyword: implant size

Search Result 294, Processing Time 0.026 seconds

The evaluation of contralateral breast's dose and shielding efficiency by breast size about breast implant patient for radiation therapy (인공 유방 확대술을 받은 환자의 유방암 치료 시 크기에 따른 반대 측 유방의 피폭 선량 및 차폐 효율 평가)

  • Kim, Jong Wook;Woo, Heon;Jeong, Hyeon Hak;Kim, Kyeong Ah;Kim, Chan Yong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.329-336
    • /
    • 2014
  • Purpose : To evaluate the dose on a contralateral breast and the usefulness of shielding according to the distance between the contralateral breast and the side of the beam by breast size when patients who got breast implant receive radiation therapy. Materials and Methods : We equipped 200 cc, 300 cc, 400 cc, and 500 cc breast model on the human phantom (Rando-phantom), acquired CT images (philips 16channel, Netherlands) and established the radiation treatment plan, 180 cGy per day on the left breast (EclipseTM ver10.0.42, Varian Medical Systems, USA) by size. We set up each points, A, B, C, and D on the right(contralateral) breast model for measurement by size and by the distance from the beam and attached MOSFET at each points. The 6 MV, 10 MV and 15 MV X-ray were irradiated to the left(target) breast model and we measured exposure dose of contralateral breast model using MOSFET. Also, at the same condition, we acquired the dose value after shielding using only Pb 2 mm and bolus 3 mm under the Pb 2 mm together. Results : As the breast model is bigger from 200 cc to 500 cc, The surface of the contralateral breast is closer to the beam. As a result, from 200 cc to 500 cc, on 180 cGy basis, the measurement value of the scattered ray inclined by 3.22 ~ 4.17% at A point, 4.06 ~ 6.22% at B point, 0.4~0.5% at C point, and was under 0.4% at D point. As the X-ray energy is higher, from 6 MV to 15 MV, on 180 cGy basis, the measurement value of the scattered ray inclined by 4.06~5% at A point, 2.85~4.94% at B point, 0.74~1.65% at C point, and was under 0.4% at D point. As using Pb 2 mm for shield, scattered ray declined by average 9.74% at A and B point, 2.8% at C point, and is under 1% at D point. As using Pb 2 mm and bolus together for shield, scattered ray declined by average 9.76% at A and B point, 2.2% at C point, and is under 1% at D point. Conclusion : Commonly, in case of patients who got breast implant, there is a distance difference by breast size between the contralateral breast and the side of beam. As the distance is closer to the beam, the scattered ray inclined. At the same size of the breast, as the X-ray energy is higher, the exposure dose by scattered ray tends to incline. As a result, as low as possible energy wihtin the plan dose is good for reducing the exposure dose.

A Study on the Artifact Reduction Method of Magnetic Resonance Imaging in Dental Implants and Prostheses (치아 임플란트와 보철에서 발생하는 자기공명영상의 인공물 감소방안 연구)

  • Shin, Woon-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.1025-1033
    • /
    • 2019
  • Although magnetic resonance imaging without linear hardening of CT is recognized as a method of obtaining high contrast of tissue and excellent resolution image in brain disease and head and neck examination, magnetic susceptibility artifact is generated in case of metal implants in the oral cavity, which is an obstacle to image diagnosis. Therefore, an effort was made in this thesis to find a method to reduce artifacts caused by dental implants and prosthesis in MRI. Implant-induced artifacts in magnetic resonance imaging showed that the signal size increased with shorter TE in GE technique and was inconsistent with water temperature change. In SE technique as well, the signal size of water was generally higher than that of air, but the signal to noise ratio (SNR) was not different by air and temperature. In EPI technique, images with fewer artifacts were obtained quantitatively and qualitatively when there was more water than air, and the signal to noise ratio was measured the highest, especially at water temperatures of 20° and 30°. In conclusion, when examining using the EPI technique rather than the SE or the GE technique, obtaining brain diffusion using a 20° and 30° water bag reduces the magnetic susceptibility artifacts caused by implants and prosthesis, suggesting that it may provide images with high diagnostic value.

Evaluation of cytotoxicity and bone affinity on the surface of a titanium phosphide (Titanium Phosphide 표면에 대한 세포독성 및 골친화성의 평가)

  • Lee, Kang-Jin;Kim, Chun-Seok;Kim, Hyung-Soo;Yum, Chang-Yup;Kim, Byung-Ock;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.2
    • /
    • pp.329-346
    • /
    • 1997
  • Dental implants have been developed for enhancement of osseointegration. Biocompatibility, bone affinity and surface characteristics of dental implants are very important factors for osseointegration. The aim of the present study was to determine the cytotoxicity and the bone affinity of titanium phosphide(Ti-P) implant material. The Ti-P surface was obtained by vacuum sintering of titanium within compacted hydroxyapatite powder. The composition and the chemical change of the surface were determined by Auger electron spectroscopy. The in vitro cytotoxicity was evaluated by the viability of the bone cells and macrophages obtained from chicken embryo and rat,s peritonium, respectively. For the comparative evaluation, 316L stainless steel, commercially pure titanium and Ti-P materials, prepared in size of 1O.0mm in diameter and 5.0mm in height, were immersed separately in bone cells and macrophages for 10 days. For the evaluation of the in vivo bone affinity, 316L stainless steel, commercially pure titanium and Ti-P materials, prepared in size of 5.0mm in diameter and 10.0mm in length, were implanted after drilling in diameter 5.5mm in femurs of 2 dogs weighing 10Kg more or less. Six weeks after implantation the specimens were prepared for histopathological examination and were observed under light microscope. In comparison of in vitro bone cell viability, Ti-P and commercially pure titanium groups were not significantly different from control group (p>O.1), but 316L stainless steel group was significantly lower than control group(p<0.05). There was no statistical difference in the viability of macrophages between 3 different groups and control group(p>O.l). In comparison of in vivo study, 316L stainless steel and commercially pure titanium showed fibrous encapsulation, but Ti-P showed remarkable new bone formation without any fibrous tissue. The results demonstrate that Ti-P has favorable biocompatibility and bone affinity, and suggest that dental implants with Ti-P surface may enhance osseointegration.

  • PDF

Influence of crestal module design on marginal bone stress around dental implant (임플란트 경부 디자인이 변연골 응력에 미치는 영향)

  • Lim, Jung-Yoel;Cho, Jin-Hyun;Jo, Kwang-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.224-231
    • /
    • 2010
  • Purpose: This study was to investigate how the crestal module design could affect the level of marginal bone stress around dental implant. Materials and methods: A submerged implant of 4.1 mm in diameter and 10 mm in length was selected as baseline model (Dentis Co., Daegu,Korea).A total of 5 experimental implants of different crestal modules were designed (Type I model : with microthread at the cervical 3 mm, Type II model : the same thread pattern as Type I but with a trans-gingival module, Type III model: the same thread pattern as the control model but with a trans-gingival module, Type IV model: one piece system with concave transgingival part, Type V model: equipped with beveled platform). Stress analysis was conducted with the use of axisy mmetric finite element modeling scheme. A force of 100 N was applied at 30 degrees from the implant axis. Results: Stress analysis has shown no stress concentration around the marginal bone for the control model. As compared to the control model, the stress levels of 0.2 mm areas away from the recorded implant were slightly lower in Type I and Type IV models, but higher in Type II, Type III and Type V models. As compared to 15.09 MPa around for the control model, the stress levels were 14.78 MPa, 18.39 MPa, 21.11 MPa, 14.63 MPa, 17.88 MPa in the cases of Type I, II, III, IV and V models. Conclusion: From these results, the conclusion was drawn that the microthread and the concavity with either crestal or trans-gingival modules maybe used in standard size dental implants to reduce marginal bone stress.

Evaluation of Metal Volume and Proton Dose Distribution Using MVCT for Head and Neck Proton Treatment Plan (두경부 양성자 치료계획 시 MVCT를 이용한 Metal Volume 평가 및 양성자 선량분포 평가)

  • Seo, Sung Gook;Kwon, Dong Yeol;Park, Se Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.25-32
    • /
    • 2019
  • Purpose: The size, shape, and volume of prosthetic appliance depend on the metal artifacts resulting from dental implant during head and neck treatment with radiation. This reduced the accuracy of contouring targets and surrounding normal tissues in radiation treatment plan. Therefore, the purpose of this study is to obtain the images of metal representing the size of tooth through MVCT, SMART-MAR CT and KVCT, evaluate the volumes, apply them into the proton therapy plan, and analyze the difference of dose distribution. Materials and Methods : Metal A ($0.5{\times}0.5{\times}0.5cm$), Metal B ($1{\times}1{\times}1cm$), and Metal C ($1{\times}2{\times}1cm$) similar in size to inlay, crown, and bridge taking the treatments used at the dentist's into account were made with Cerrobend ($9.64g/cm^3$). Metal was placed into the In House Head & Neck Phantom and by using CT Simulator (Discovery CT 590RT, GE, USA) the images of KVCT and SMART-MAR were obtained with slice thickness 1.25 mm. The images of MVCT were obtained in the same way with $RADIXACT^{(R)}$ Series (Accuracy $Precision^{(R)}$, USA). The images of metal obtained through MVCT, SMART-MAR CT, and KVCT were compared in both size of axis X, Y, and Z and volume based on the Autocontour Thresholds Raw Values from the computerized treatment planning equipment Pinnacle (Ver 9.10, Philips, Palo Alto, USA). The proton treatment plan (Ray station 5.1, RaySearch, USA) was set by fusing the contour of metal B ($1{\times}1{\times}1cm$) obtained from the above experiment by each CT into KVCT in order to compare the difference of dose distribution. Result: Referencing the actual sizes, it was appeared: Metal A (MVCT: 1.0 times, SMART-MAR CT: 1.84 times, and KVCT: 1.92 times), Metal B (MVCT: 1.02 times, SMART-MAR CT: 1.47 times, and KVCT: 1.82 times), and Metal C (MVCT: 1.0 times, SMART-MAR CT: 1.46 times, and KVCT: 1.66 times). MVCT was measured most similarly to the actual metal volume. As a result of measurement by applying the volume of metal B into proton treatment plan, the dose of $D_{99%}$ volume was measured as: MVCT: 3094 CcGE, SMART-MAR CT: 2902 CcGE, and KVCT: 2880 CcGE, against the reference 3082 CcGE Conclusion: Overall volume and axes X and Z were most identical to the actual sizes in MVCT and axis Y, which is in the superior-Inferior direction, was regular in length without differences in CT. The best dose distribution was shown in MVCT having similar size, shape, and volume of metal when treating head and neck protons. Thus it is thought that it would be very useful if the contour of prosthetic appliance using MVCT is applied into KVCT for proton treatment plan.

SURFACE CHARACTERISTICS OF ANODIC OXIDIZED TITANIUM ACCORDING TO THE PORE SIZE

  • Ha Heon-Seok;Kim Chang-Whe;Lim Young-Jun;Kim Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.343-355
    • /
    • 2006
  • Statement of problem. The success of osseointegration can be enhanced with an implant that has improved surface characteristics. Anodic oxidation is one of the surface modifying method to achieve osseointegration. Voltage of anodic oxidation can change surface characteristics and cell activity Purpose. This study was performed to evaluate MG63 cell responses such as affinity, proliferation and to compare surface characteristics of anodic oxidized titanium in various voltage. Material and method. The disks for cell culture were fabricated from grade 3 commercially pure titanium,1 m in thickness and 12 mm in diameter. Surfaces of 4 different roughness were prepared. Group 1 had a machined surface, used as control. Group 2 was anodized under 220 V, group 3 was anodized under 300 V and group 4 was anodized under 320 V. The microtopography of specimens was observed by scanning electron microscope (JSM-840A, JEOL, Japan) and atomic force microscope(Autoprobe CP, Park Scientific Instrument, USA). The surface roughness was measured by confocal laser scanning microscope(Pascal, LSM5, Zeiss, Germany). The crystal structure of the titanium surface was analyzed with x-ray diffractometer(D8 advanced, Broker, Germany). MG63 osteoblast-like cells were cultured on these specimens. The cell morpholgy was observed by field emission electron microscope(Hitachi S-4700, Japan). The cell metabolic and proliferative activity was evaluated by MTT assay Results and conclusion. With in limitations of this in vitro study, the following conclusions were drawn. 1. In anodizing titanium surface, we could see pores which did not show in control group. In higher anodizing voltage, pore size was increased. 2. In anodizing titanium surface, we could see anatase. In higher anodizing voltage, thicker oxide layer increased crystallinity(anatase, anatase and rutile mixed). 3. MG63 cells showed more irregular, polarized and polygonal shape and developed more lamellipodi in anodizing group as voltage increased. 4. The activity of cells in MTT assay increased significantly in group 3 and 4 in comparison with group 1 and 2. However, there was no difference between group 3 and 4 at P<0.05. Proliferation of MG63 cells increased significantly in pore size($3-5.5{\mu}m$) of group 3 and 4 in comparison with in pore size($0.2-1{\mu}m$ ) of group 2.

Growth of sea cucumber (Apostichopus japonicus, Selenka) to different stocking densities and body sizes, with monitoring and the use of VIE tags (해상에서 VIE 추적 조사에 의한 양성 기구의 수용 밀도 및 개체 크기별 해삼 (Apostichopus japonicus, Selenka)의 성장 비교)

  • MOON, Sunju;KWON, Inyeong;KIM, Taeho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.53 no.1
    • /
    • pp.49-59
    • /
    • 2017
  • The objective of this study was to investigate the growth rate and the optimal stocking density of sea cucumbers. Grow-out was studied in situ by conducting a follow-up survey using visible implant elastomer (VIE) tags. The rearing systems were made of polypropylene pipe for the frames and netting. The experiment ran for 70 days near Yeosu, Korea in the water depth of about 7 m. A total of 576 sea cucumbers which have three groups of body sizes (small: 5.15, medium: 12.34 and large: 23.26 g) were used. The five groups of stocking densities (150, 300, 450, 600 and $850g/m^2$) in rearing system for sea cucumber were considered. Sea cucumbers were fed a mixed diet (mud, mineral, fish meal, etc.). The feed was supplied to 10% of their body wet weight once every 7 days. The survival rate (73%) of sea cucumber in $850g/m^2$ was lower than those of other density groups ($150g/m^2$: 89%, $300g/m^2$: 84%, $450g/m^2$: 78% and $600g/m^2$: 86%). The survival rate of medium size group was higher than those of small and large groups regardless of the density (P<0.05). Most of density groups have no significant difference except for $850g/m^2$ (P>0.05). The growth rate of small size group ($0.63%day^{-1}$) was higher than those of medium ($0.38%day^{-1}$) and large ($0.34%day^{-1}$) group regardless of the density (P<0.05). The threshold water temperature was $11.0^{\circ}C$ for sea cucumber growth in winter season.

The Effect of HEMM on Microstructure and Mechanical Properties of Ti-Nb Alloy for Implant Biomedical Materials (생체의학 임플란트재료로서 Ti-Nb계 합금의 조직과 기계적 성질에 미치는 HEMM의 영향)

  • Woo, Kee-Do;Choi, Gab-Song;Lee, Hyun-Bum;Kim, In-Yong;Zhang, Deliang
    • Korean Journal of Materials Research
    • /
    • v.17 no.11
    • /
    • pp.587-592
    • /
    • 2007
  • Al-42wt%Nb powder was prepared by high-energy mechanical milling(HEMM). The particle size, phase transformation and microstructure of the as-milled powder were investigated by particle size distribution (PSD) analyzer, scanning electron microscopy (SEM), X-ray diffractometery (XRD), transmission electron microscopy (TEM)and differential thermal analysis (DTA). The milled powders were heated to a sintering temperature at 1000C with under vaccum with vaccum tube furnace. Microstructural examination of sintered Ti-42wt%Nb alloy using 4h-milled powder showed Ti-rich phases (${\alpha}$-Ti) which are fine and homogeneously distributed in the matrix (Nb-rich phase: ${\beta}$-Ti). The sintered Ti-42wt%Nb alloy with milled powder showed higher hardness. The microstructure of the as quenched specimens fabricated by sintering using mixed and milled powder almost are same, but the hardness of as quenched specimen fabricated by using mixed powder increased due to solution hardening of Nb in Ti matrix. The aging effect of these specimens on microstructural change and hardening is not prominent.

Cone-beam computed tomography artifacts in the presence of dental implants and associated factors: An integrative review

  • Terrabuio, Bianca Rodrigues;Carvalho, Caroline Gomes;Peralta-Mamani, Mariela;da Silva Santos, Paulo Sergio;Rubira-Bullen, Izabel Regina Fischer;Rubira, Cassia Maria Fischer
    • Imaging Science in Dentistry
    • /
    • v.51 no.2
    • /
    • pp.93-106
    • /
    • 2021
  • Purpose: This study was conducted to review the literature regarding the types of cone-beam computed tomography (CBCT) artifacts around dental implants and the factors that influence their formation. Materials and Methods: A search strategy was carried out in the PubMed, Embase, and Scopus databases to identify published between 2010 and 2020, and 9 studies were selected. The implants included 306 titanium, titanium-zirconium, and zirconia implants, as well as 5 titanium cylinders. Results: The artifacts around the implants were the beam-hardening artifact, the streaking artifact, and band-like radiolucent areas. Some factors that influenced the formation of artifacts were the implant material, bone type, evaluated regions, distance, type of CBCT, field of view (FOV) size, milliamperage, peak kilovoltage (kVp), and voxel size. The beam-hardening artifact was the most widely reported, and it was minimized in protocols with a smaller FOV, larger voxels, and higher kVp. Conclusion: The risk and benefit of these protocols in individuals with dental implants must be considered, and clinical examinations and complementary radiographs play an essential role in implantology.

Tissue Expanders in Staged Calvarial Reconstruction: A Systematic Review

  • Andrea Y. Lo;Roy P. Yu;Anjali C. Raghuram;Michael N. Cooper;Holly J. Thompson;Charles Y. Liu;Alex K. Wong
    • Archives of Plastic Surgery
    • /
    • v.49 no.6
    • /
    • pp.729-739
    • /
    • 2022
  • Cranioplasties are common procedures in plastic surgery. The use of tissue expansion (TE) in staged cranioplasties is less common. We present two cases of cranioplasties with TE and systematically review literature describing the use of TE in staged cranioplasties and postoperative outcomes. A systematic review was performed by querying multiple databases. Eligible articles include published case series, retrospective reviews, and systematic reviews that described use of TE for staged bony cranioplasty. Data regarding study size, patient demographics, preoperative characteristics, staged procedure characteristics, and postoperative outcomes were collected. Of 755 identified publications, 26 met inclusion criteria. 85 patients underwent a staged cranioplasty with TE. Average defect size was 122 cm2, and 30.9% of patients received a previous reconstruction. Average expansion period was 14.2 weeks. The most common soft tissue closures were performed with skin expansion only (75.3%), free/pedicled flap (20.1%), and skin graft (4.7%). The mean postoperative follow-up time was 23.9 months. Overall infection and local complication rates were 3.53 and 9.41%, respectively. The most common complications were cerebrospinal fluid leak (7.1%), hematoma (7.1%), implant exposure (3.5%), and infection (3.5%). Factors associated with higher complication rates include the following: use of alloplastic calvarial implants and defects of congenital etiology (p = 0.023 and 0.035, respectively). This is the first comprehensive review to describe current practices and outcomes in staged cranioplasty with TE. Adequate soft tissue coverage contributes to successful cranioplasties and TE can play a safe and effective role in selected cases.