• Title/Summary/Keyword: impedance characteristics

Search Result 1,741, Processing Time 0.024 seconds

Improvement of Signal Transfer Characteristics of Fine Pitch Probe Pin Using Coaxial Test Socket with New Structure (새로운 구조의 동축 테스트 소켓을 이용한 미세 피치 프로브 핀의 신호 전달 특성 개선)

  • Jeong-Jun Seo;Moonjung Kim
    • Journal of the Semiconductor & Display Technology
    • /
    • v.23 no.1
    • /
    • pp.97-103
    • /
    • 2024
  • In this paper, the difference between the S-parameter and the characteristic impedance according to the structural change of the fine pitch coaxial socket was analyzed. A pitch of the probe pin was applied to 0.20mm, and ground pins of different conditions were placed on each of the five signal pins. Insertion loss and reflection loss were analyzed for the coaxial socket of normal structure and the two sockets of the proposed structure. In addition, the difference in characteristic impedance was analyzed using time domain reflectometry. Through the analysis, it was confirmed that the characteristic impedance was improved applying the new structures of the socket at the same pitch

  • PDF

Study on Characteristics of Various RF Transmission Line Structures on PES Substrate for Application to Flexible MMIC

  • Yun, Young;Kim, Hong Seung;Jang, Nakwon
    • ETRI Journal
    • /
    • v.36 no.1
    • /
    • pp.106-115
    • /
    • 2014
  • In this work, the coplanar waveguide is fabricated on a PES (poly[ether sulfone]) substrate for application to a flexible monolithic microwave integrated circuit, and its RF characteristics were thoroughly investigated. The quality factor of the coplanar waveguide on PES is 40.3 at a resonance frequency of 46.7 GHz. A fishbone-type transmission line (FTTL) structure is also fabricated on the PES substrate, and its RF characteristics are investigated. The wavelength of the FTTL on PES is 5.11 mm at 20 GHz, which is 55% of the conventional coplanar waveguide on PES. Using the FTTL, an impedance transformer is fabricated on PES. The size of the impedance transformer is $0.318mm{\times}0.318mm$, which is 69.2% of the size of the transformer fabricated by the conventional coplanar waveguide on PES. The impedance transformer showed return loss values better than -12.9 dB from 5 GHz to 50 GHz and an insertion loss better than -1.13 dB in the same frequency range.

A Study for Mutual Interference of LCL Filter Under Parallel Operation of Grid-Connected Inverters (계통연계형 인버터 병렬운전 시 LCL 필터 상호간섭 특성 연구)

  • Lee, Gang;Seo, Joungjin;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.2
    • /
    • pp.75-81
    • /
    • 2021
  • This study analyzes the resonance characteristics caused by the mutual interference between LCL filters and the grid impedance under the parallel operation of the grid-connected inverter using the LCL filter. These characteristics are verified through simulation and experiment. Two inverters are used to connect to the grid in parallel, and the system parameters, including the LCL filter, are set to the same conditions. In the case of inverters running in parallel at the point of common coupling, the presence of grid impedance causes mutual interference between the LCL filters of each inverter, and the deviation of the filter resonance frequency is analyzed to understand the parallel inverter. The correlation between the number of devices and the size of grid impedance is simulated by PSIM and verified by MATLAB. By connecting the real-time digital simulator Typhoon HILS to the DSP 28377 control board, the mutual interference characteristics are tested under the condition of two inverters running in parallel. The experimental and analysis results are the same, indicating the validity of the analysis.

Acoustic Characteristics of a .Silencer by Using Array Resonators (공명기 배열을 이용한 소음기의 음향학적 특성)

  • 김양한;서상현
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.10
    • /
    • pp.975-982
    • /
    • 2004
  • Helmholtz resonator is used to reduce noise of the narrow frequency band. It has high transmission loss at its resonance frequency. The silencer that combines many resonators could control broadband noise at low frequency. To convey this rather simple idea, serial and parallel arrangement of resonators have been tested to obtain high transmission loss characteristics in the band of which are selects. Theoretical and experimental results explain these characteristics in the absence of mean flow. The change of acoustic characteristics by the resonance frequencies and resonators arrangement are explained by using the equivalent Impedance analysis that is defined in this paper. It shows that the transmission loss has a maximum value when the separation distance between each resonator is λ/4 of its wavelength.

Evaluation of Discharge Characteristics Followed by the Development of Blumlein Pulsed Power Source (Blumlein 펄스파워 전원개발 및 방전특성 평가)

  • Han, Sang-Bo;Park, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.99-105
    • /
    • 2010
  • This paper discussed the theoretical simulation results for developing the blumlein pulsed power source and showed the circuit configuration and the discharge characteristics of the realistic manufactured pulsed power system. In the simulation, the output voltage characteristics at a load resistor showed the general impulse shape when the impedance of a single coaxial cable is matched with the that of a load resistor. In addition, it is confirmed that output values of the pulsed power can be easily controlled by the duplication of coaxial cables and the pulsed waveform showed the general impulse characteristics. Specifically, the inception discharge voltage in the gap distance of 5[mm] between needle and plane electrodes is about 20[kV] and which is lower than about 29[kV] in 9[mm] due to the difference of the reaching time of the inception voltage. Therefore, this paper showed that the output voltage of the blumlein pulsed power source can be easily controlled.

Characteristics for Ground Impedance according to Distance of Current Probe and Frequency (전류보조전극 거리 및 주파수에 따른 접지임피던스 특성)

  • Gil, Hyoung-Jun;Lee, Ki-Yeon;Moon, Hyun-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.122-128
    • /
    • 2010
  • This paper presents the characteristics for ground impedance of combined three rods according to distance of current probe and frequency using the fall-of-potential method and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position of auxiliary probes. In order to analyze the effects of ground impedance due to the distance of the current probe and frequency, ground impedances were measured in case that the distance of current probe was located from 5[m] to 20[m] and the measuring frequency was ranged in 55~513[Hz]. The results could be help to determine the position of current probe and the measuring frequency when the ground impedance was measured at grounding system.

Characteristics Analysis of Transient Impedances of Small-sized Ground Electrodes in a Ionization Region of Soil (토양의 이온화영역에서 소규모 접지전극의 과도접지임피던스 특성 분석)

  • Yoo, Yang-Woo;Eom, Ju-Hong;Cho, Sung-Chul;Lee, Tae-Hyung;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.78-84
    • /
    • 2009
  • This paper presents measurement results of transient impedance for small-sized ground electrodes in a discharge region of soil. For a realistic analysis of ionization characteristics near the ground electrode, three types of ground rod installed outdoors and high voltage impulse generator were used for injecting test current. From the analysis of response voltage and current flowing ground electrode to earth, it is verified that the ionization near the ground electrode contributes to reduction of ground impedance and limits the ground potential rise effectively in high resistivity soil. As a threshold electric field density for ionization is small in low resistivity soil, the shape of ground electrode rarely contributes to the transient impedance. And, from the experiment result with shape of ground electrode, the rod with needles is more effective to reduce the transient impedance than the plate electrode in the voltage range including with ionization regions of soil.

Ground Impedance Characteristics Analysis of a Rod Type Grounding Electrode used for Distribution Systems (배전계통에 사용되는 봉형 접지전극의 접지 임피던스 특성 분석)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Joo-Hong;Kim, You-June;Choi, Jong-Ki;Baek, Nam-Woong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.67-74
    • /
    • 2005
  • Grounding insures a reference potential point for electric devices and also provides a low resistance path for fault currents in the earth. The ground impedance as a function of frequency is necessary for determining its performance since fault currents could contain a wide range of frequencies. In this paper, the ground impedance of Magic rods which are commercially available has been measured in frequency ranging from 0[Hz] up to 100[kHz] and an equivalent circuit model, transfer function model of the ground impedance are identified from the measured values.

Ground Impedance Characteristics Analysis of a Copper Rod-type Grounding Electrode used for Electric Distribution Systems (배전계통에 사용되는 동봉 접지전극의 접지 임피던스 특성 분석)

  • Kim, Kyung-Chul;Lee, Joo-Hong;Jin, Seong-Eun;Oh, Jung-Suk;Park, Sang-Young;Choi, Jong-Ki;Kim, You-June
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.46-51
    • /
    • 2005
  • Grounding insures a reference potential point for electric devices and also provides a low resistance path for fault currents in the earth. The ground impedance as a function of frequency is necessary for determining its performance since fault currents could contain a wide range of frequencies. A cower rod electrode is the most commonly used grounding electrode in electric distribution systems. In this paper, the ground impedance of cower rods has been measured in frequency ranging from 60[Hz] up to 100[kHz] and an equivalent circuit model, transfer function model of the ground impedance are identified from the measured values.

Impedance-based Long-term Structural Health Monitoring for Tidal Current Power Plant Structure in Noisy Environments (잡음 환경 하에서의 전기-역학적 임피던스 기반 조류발전 구조물의 장기 건전성 모니터링)

  • Min, Ji-Young;Shim, Hyo-Jin;Yun, Chung-Bang;Yi, Jin-Hak
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.59-65
    • /
    • 2011
  • In structural health monitoring (SHM) using electro-mechanical impedance signatures, it is a critical issue for extremely large structures to extract the best damage diagnosis results, while minimizing unknown environmental effects, including temperature, humidity, and acoustic vibration. If the impedance signatures fluctuate because of these factors, these fluctuations should be eliminated because they might hide the characteristics of the host structural damages. This paper presents a long-term SHM technique under an unknown noisy environment for tidal current power plant structures. The obtained impedance signatures contained significant variations during the measurements, especially in the audio frequency range. To eliminate these variations, a continuous principal component analysis was applied, and the results were compared with the conventional approach using the RMSD (Root Mean Square Deviation) and CC (Cross-correlation Coefficient) damage indices. Finally, it was found that this approach could be effectively used for long-term SHM in noisy environments.