• 제목/요약/키워드: imaging physics

검색결과 634건 처리시간 0.04초

Image Quality Evaluation and Tolerance Analysis for Camera Lenses with Diffractive Element

  • Lee, Sang-Hyuck;Jeong, Ho-Seop;Jin, Young-Su;Song, Seok-Ho;Park, Woo-Je
    • Journal of the Optical Society of Korea
    • /
    • 제10권3호
    • /
    • pp.105-111
    • /
    • 2006
  • A novel image quality evaluation method, which is based on combination of the rigorous grating diffraction theory and the ray-optic method, is proposed. It is applied for design optimization and, tolerance analysis of optical imaging systems implementing diffractive optical elements (DOE). The evaluation method can predict the quality and resolution of the image on the image sensor plane through the optical imaging system. Especially, we can simulate the effect of diffraction efficiencies of DOE in the camera lenses module, which is very effective for predicting different color sense and MTF performance. Using this method, we can effectively determine the fabrication tolerances of diffractive and refractive optical elements such as the variations' in profile thickness, and the shoulder of the DOE, as well as conventional parameters such as decenter and tilt in optical-surface alignments. A DOE-based 2M-resolution camera lens module designed by the optimization process based on the proposed image quality evaluation method shows ${\sim}15%$ MTF improvement compared with a design without such an optimization.

반사형 디지털 홀로그래피 현미경 시스템에서의 조사면적 및 재생면적의 확대기록 (Recording and Reconstruction of large object area by using Reflection type Digital Holography Microscope System)

  • 최규환;김성규;조동현;윤선규
    • 한국광학회지
    • /
    • 제17권4호
    • /
    • pp.335-341
    • /
    • 2006
  • 마이켈슨 간섭계 시스템에 두 개의 Convex Lens를 추가함으로서 평면파 참조광을 유지 시키며, 물체에 조사되는 물체광의 조사면적을 증대시킬 수 있는 변형된 마이켈슨 간섭계를 제작하였다. 변형된 마이켈슨 간섭계를 반사형 디지털 홀로그래피 현미경 시스템(Digital Holography Microscope System)에 적용한 결과 두 개의 Convex Lens를 추가하지 않은 고전 마이켈슨 간섭계를 사용한 디지털 홀로그래피 현미경 시스템 보다 넓은 영역에 대해 물체를 기록 할 수 있으며 또한 보다 넓은 영역을 재생 할 수가 있다.

SOLAR ACTIVE REGION STUDY USING MICROWAVE MAPS

  • BONG SU-CRAN;LEE JEONGWOO;GARY DALE E.;YUN HONG SIK
    • 천문학회지
    • /
    • 제36권spc1호
    • /
    • pp.29-36
    • /
    • 2003
  • Quiescent solar radiation, at microwave spectral regime, is dominated by gyroresonant and thermal Bremsstrahlung radiations from hot electrons residing in solar active region corona. These radiations are known to provide excellent diagnostics on the coronal temperature, density, and magnetic field, provided that spatially resolved spectra are available from observations. In this paper we present an imaging spectroscopy implemented for a bipolar active region, AR 7912, using the multifrequency interferometric data from the Owens Valley Solar Array (OVSA), as processed with a new imaging technique, so-called Spatio-Spectral Maximum Entropy Method (SSMEM). From the microwave maps at 26 frequencies in the range of 1.2-12.4 GHz at both right- and left-circular polarizations, we construct spatially resolved brightness spectra in every reconstructed pixel of about 2 arcsec interval. These spectra allowed us to determine 2-D distribution of electron temperature, magnetic field of coronal base, and emission measure at the coronal base above the active region. We briefly compare the present result with existing studies of the coronal active regions.

DESIGN CONCEPT FOR SINGLE CHIP MOSAIC CCD CONTROLLER

  • HAN WONYONG;JIN Ho;WALKER DAVID D.;CLAYTON MARTIN
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.389-390
    • /
    • 1996
  • The CCDs are widely used in astronomical observations either in direct imaging use or spectroscopic mode. However, the areas of available sensors are too small for large imaging format. One possibility to obtain large detection area is to assemble mosaics of CCD, and drive them simultaneously. Parallel driving of many CCDs together rules out the possibility of individual tuning; however, such optimisation is very important, when the ultimate low light level performance is required, particularly for new, or mixed devices. In this work, a new concept is explored for an entirely novel approach, where the drive waveforms are multiplexed and interleaved. This simultaneously reduces the number of leadout connections and permits individual optimisation efficiently. The digital controller can be designed within a single EPLD (Erasable Programmable Logic Device) chip produced by a CAD software package, where most of the digital controller circuits are integrated. This method can minimise the component. count., and improve the system efficiency greatly, based on earlier works by Han et a1. (1996, 1994). The system software has an open architecture to permit convenient modification by the user, to fit their specific purposes. Some variable system control parameters can be selected by a user with a wider range of choice. The digital controller design concept allows great flexibility of system parameters by the software, specifically for the compatibility to deal with any number of mixed CCDs, and in any format, within the practical limit.

  • PDF

FISS and SDO Observation of a Brightening Event Near a Pore

  • Kang, Juhyeong;Chae, Jongchul
    • 천문학회보
    • /
    • 제42권2호
    • /
    • pp.61.2-61.2
    • /
    • 2017
  • We report a fine scale transient brightening event near a pore boundary with the Fast Imaging Solar Spectrograph (FISS) of the 1.6m Goode Solar Telescope (GST), the Atmospheric Imaging Assembly (AIA) aboard the Solar Dynamics Observatory (SDO), and Helioseismic and Magnetic Imager (HMI) aboard SDO. The event appears in all AIA extreme ultraviolet bands, also in the two FISS lines, $H{\alpha}$ and Ca II $8542{\AA}$, and lasted for a minute. The brightening occurred at a footpoint of a loop. The conjugate brightening occurred at the other foot point outside the FISS field of view. The brightening near the pore exhibit a redshift of 4.3 km s-1 in the $H{\alpha}$ and about 2.3 km s-1 in Ca II line. Differential emission measure derived from 6 AIA EUV passbands and cloud model fitting of the two FISS lines indicate the temperature increase of between 10,000 and 20 MK at the main event. After the brightening, the upward mass motion appears in the AIA images. We discuss the physical implication of this brightening in the context of magnetic reconnection and coronal heating.

  • PDF

Application of Hydrogenated Amorphous Silicon(a-Si : H) Radiation Detectors in Nuclear Medicine

  • Lee, Hyoung-Koo;Mendez, Victor-Perez;Shinn, Kyung-Sub
    • 한국의학물리학회지:의학물리
    • /
    • 제6권1호
    • /
    • pp.65-77
    • /
    • 1995
  • A new gamma camera using a-Si : H photodetectors has been designed for the imaging of heart and other small organs. In this new design the photomultiplier tubes and the position sensing circuitry are replaced by 2-D array of a-Si : H p-i-n pixel photode tectors and readout circuitry which are built on a substrate. Without the photomultiplier tubes this camera is light weight, hence can be made portable. To predict the characteristics and the performance of this new gamma camera we did Monte Carlo simulations. In the simulations 128${\times}$128 imaging array of various pixel sixes were used. $\^$99m/Tc(140keV)and $\^$201/Tl(70keV) were used as radiation sources. From the simulations we could obtain the resolution of the camera and ther overall system, and the blurring effects due to scattering in the phantom. Using the Wiener filter for image processing, restoration of the blurred image could be achieved. Simulation results of a-Si : H based gamma camera were compared with those of a conwentional gamma camera.

  • PDF

Performance Evaluation of a Rapid Three Dimensional Diffusion MRI

  • Numano, Tomokazu;Homma, Kazuhiro;Nishimura, Katsuyuki
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.356-358
    • /
    • 2002
  • MRI, particularly diffusion weighted imaging (DWI), plays vital roles in detection of the acute brain infarction$\^$1-4/ and others metabolic changes of biological tissues. In general, every molecule in biological tissues may diffuse and move randomly in three-dimensional space. However, in clinical diagnosis, only 2D-DWI is used. The authors have developed a new method for rapid three-dimensional DWI (3D-DWI). In this method, by refocusing of the magnetized spin with the applied gradient field, direction of which is opposite to phase encoding field. Magnetized spin of $^1$H is kept under the SSFP (steady state free precession)$\^$5-6/. Under SSFP, in addition of FID, spin echo and stimulated echo are also generated, so the acquired signal is increased. The signal intensity is increased depending on flip angle (FA) of magnetized spin. This phenomenon is confirmed by human brain and phantom studies. The performance of this method is quantitatively analyzed by using both of conventional spin echo DWI and 3D-DWI. From experimental results, three dimensional diffusion weighted images are obtained correctly for liquid phantoms (water, acetone and oil), diffusion coefficient is enhanced in each image. Therefore, this method will provide useful information for clinical diagnosis.

  • PDF

Effect of Particulate Matter on Human Health, Prevention, and Imaging Using PET or SPECT

  • Zaheer, Javeria;Jeon, Jongho;Lee, Seung-Bok;Kim, Jin Su
    • 한국의학물리학회지:의학물리
    • /
    • 제29권3호
    • /
    • pp.81-91
    • /
    • 2018
  • Particulate matter (PM) in dust causes serious pathological conditions, and it has been considered a critical health issue for many years. Respiratory disorders such as bronchitis, asthma, and chronic inflammation, are the most common illnesses due to PM that appears as dust. There is evidence that cardiovascular and neurological abnormalities are caused by PM. Although an extensive amount of work has been conducted on this topic, including studies on the nature of the particles, particle size measurements, particle distribution upon inhalation, the health effects of fine particles, disease prevention, diagnosis, and treatment, to this date, there is still a considerable lack of knowledge in these areas. Therefore, the identification of the key components that cause diseases owing to PM, and the specific diagnoses of the diseases, is important. This review will explore the current literature on the origin and nature of PM and their effects on human health. In addition, it will also highlight the approaches that have been adopted in order to diagnose the effects of PM using positron emission tomography (PET) or single-photon emission computerized tomography (SPECT).

EFFECTIVE DOSE MEASUREMENT FOR CONE BEAM COMPUTED TOMOGRAPHY USING GLASS DOSIMETER

  • Moon, Young Min;Kim, Hyo-Jin;Kwak, Dong Won;Kang, Yeong-Rok;Lee, Man Woo;Ro, Tae-Ik;Kim, Jeung Kee;Jeong, Dong Hyeok
    • Nuclear Engineering and Technology
    • /
    • 제46권2호
    • /
    • pp.255-262
    • /
    • 2014
  • During image-guided radiation therapy, the patient is exposed to unwanted radiation from imaging devices built into the medical LINAC. In the present study, the effective dose delivered to a patient from a cone beam computed tomography (CBCT) machine was measured. Absorbed doses in specific organs listed in ICRP Publication 103 were measured with glass dosimeters calibrated with kilovolt (kV) X-rays using a whole body physical phantom for typical radiotherapy sites, including the head and neck, chest, and pelvis. The effective dose per scan for the head and neck, chest, and pelvis were $3.37{\pm}0.29$, $7.36{\pm}0.33$, and $4.09{\pm}0.29$ mSv, respectively. The results highlight the importance of the compensation of treatment dose by managing imaging dose.

단백질 칩 기판의 플라즈마 효과 (Effects of Plasma on the Surface of Protein Chip Plates)

  • 현준원;김나연
    • 한국진공학회지
    • /
    • 제17권6호
    • /
    • pp.549-554
    • /
    • 2008
  • 수소 플라즈마 처리된 유리 기판에 스핀 코팅 시스템을 이용하여 nickel chloride를 코팅하여 단백질칩 플레이트를 제조하였다. 다양한 플라즈마 처리 시간대에서 histidine tagged 단백질의 부착 능력 특성을 연구하였다. 유리 기판 표면에서 nickel chloride와 단백질 특성을 particle size analysis를 이용하여 관찰하였고, 단백질의 부착 능력 정도를 bio imaging analyzer system으로 측정하였다. 실험 결과에 따르면, 플라즈마 처리 시간이 증가할수록 단백질 부착 능력은 감소하는 것으로 나타났다. 기판 표면에서의 단백질 부착능력 특성에 관한 mechanism은 본문의 결과 및 토의에서 논의되었다. 플라즈마 처리된 단백질칩 기판에 대한 표면 안정화는 바이오센서 시장에서 큰 관심을 끌 것으로 기대된다.