• Title/Summary/Keyword: holdover

Search Result 12, Processing Time 0.027 seconds

A Frequency Model of OCXO for Holdover Mode of DP-PLL (DP-PLL의 Holdover 모드에 대한 OCXO의 주파수 모델)

  • Han, Wook;Hwang, Jin-Kwon;Kim, Yung-Kwon
    • Journal of IKEEE
    • /
    • v.4 no.2 s.7
    • /
    • pp.266-273
    • /
    • 2000
  • A frequency model of an OCXO (Oven Controlled X-tal Oscillator) is suggested to implement a holdover algorithm in a DP-PLL (Digital Processing-Phase Locked Loop) system. This model is presented simply with second order polynomials with respect to temperature and aging of the OCXO. The model parameters are obtained from experimental data by applying the LSM (Least Squared Method). A holdover algorithm is also suggest using the frequency model. The obtained model is verified to simulate the holdover algorithm with experimental phase data due to variation of temperature.

  • PDF

Estimation of GPS Holdover Performance with Ladder Algorithm Used for an UFIR Filter (UFIR 필터 Ladder 알고리즘 이용 GPS Holdover 성능 추정)

  • Lee, Young-kyu;Yang, Sung-hoon;Lee, Chang-bok;Heo, Moon-beom
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.7
    • /
    • pp.669-676
    • /
    • 2015
  • In this paper, we described the simulation results of the phase offset performance of a clock in holdover mode which was normally operated in GPS Disciplined Oscillator (GPSDO). In the TIE model, we included the time error term caused by environmental temperature variation because one of the most important parameters of clock phase error is the frequency offset and drift caused by the variation of temperature. For the simulation, we employed Maximum Time Interval Error (MTIE) for the performance evaluation when the frequency offset and drift are estimated by using an Unbiased Finite Impulse Response (UFIR) filter with ladder algorithm. We assumed that the noise in the GPS measurement is white Gaussian with zero mean and 1 ns standard deviation, and temperature linearly varies with a slope of $1{^{\circ}C}$ per hour. From the simulation results, the followings were observed. First, with the estimation error of temperature of less than 3 % and the temperature compensation period of less than 900 seconds, the requirement of CDMA2000 phase synchronization under 10 us could be achieved for more than 40,000 seconds holdover time if we employ an OCXO (Oven Controlled Crystal Oscillator) clock. Second, in order to achieve the requirement of LTE-TDD under 1.5 us for more than 10,000 seconds holdover time, below 3 % estimation error and 500 seconds should be retained if a Rubidium clock is adopted.

Method of Clock Noise Generation Corresponding to Clock Specification

  • Lee, Young Kyu;Yang, Sung Hoon;Lee, Chang Bok;Kim, Sanhae;Song, Kyu-Ha;Lee, Wonjin;Ko, Jae Heon
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.5 no.3
    • /
    • pp.157-163
    • /
    • 2016
  • Clocks for time synchronization using radio signals such as global navigation satellite system (GNSS) may lose reference signals by intentional or unintentional jamming. This is called as holdover. When holdover occurs, a clock goes into free run in which synchronization performance is degraded considerably. In order to maintain the required precise time synchronization during holdover, accurate estimation on main parameters such as frequency offset and frequency drift is needed. It is necessary to implement an optimum filter through various simulation tests by creating clock noise in accordance with given specifications in order to estimate the main parameters accurately. In this paper, a method that creates clock noise in accordance with given specifications is described.

Design and Fabrication of Synchronous Clock Recovery Module for S-DMB GaP Filler (위성 DMB 중계기의 동기용 클럭 재생 모듈 설계 및 제작)

  • Chang, Lae-Kyu;Park, Eun-Hee;Lee, Hang-Soo;Hong, Sung-Yong;Park, Jung-Seo
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.107-110
    • /
    • 2005
  • This paper describes the design and fabrication of synchronous clock recovery module for S-DMB Gap Filler. Using the 2.304MHz TTL signal from gap filler tuner, clock recovery module with 10MHz output frequency including holdover function is designed. The measured performance of the clock recovery module shows a stability of less than 0.01ppm, 29 sec stability time, 10 sec holdover time, and maximum -113dBc/Hz@100Hz phase noise.

  • PDF

Realization of an IEEE 802.11g VoWLAN Terminal with Support of Adaptable Power Save and QoS During a Call (통화 중 적응적 Power Save와 QoS 지원이 가능한 IEEE B02.11g VoWLAN 단말기 구현)

  • Kwon, Sung-Su;Lee, Jong-Chul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.10A
    • /
    • pp.1003-1013
    • /
    • 2006
  • There is a serious problem in an 802.11g VoWLAN (Voice over Wireless LAN) terminal that talk time is less than 30% compared with an 802.11b terminal. It is almost impossible to achieve talk time level of the 802.11b MAC transmission method because IEEE 802.11g uses OFDM modulation, which is a kind of multi-carrier method and OFDM transmission speed is 54 Mbps faster than normal modulation. In this paper, a new concept of a Holdover time as a power saving method during a call with 802.11g terminal is suggested for the first time. Increase in the number of engaged terminals as a result of holdover time causes to QoS problem because of the increase in the number of back-off and then contention window. In this paper, to solve the QoS problem, a new approach is suggested such that when in down lint the sequence number of 802.11 G.711 is analyzed in the MAC of the terminal and then the Hold over time depending on loss rate is changed. Also, consumption of an electric current of 802.11b/g and MAC parameter's performance due to busy traffic caused by increase in the number of terminal are analyzed and then real data using VQT and Airopeek are analyzed.

The Study of FAA's certification policy for approving the ground use of deicing/anti-icing fluids on airplane (항공기용 결빙방지액의 지상 사용승인을 위한 FAA의 최근 인증정책 연구)

  • Kim, You gwang
    • Journal of Aerospace System Engineering
    • /
    • v.7 no.3
    • /
    • pp.51-57
    • /
    • 2013
  • This study describes the Federal Aviation Administration(FAA) certification policy for approving the use of Type II, III, and IV deicing/anti-icing fluids on small category airplanes. These fluids can be characterized as non-Newtonian, pseudo-plastic fluids, also known as "thickened" fluids. Deicing fluids are used before takeoff to remove frost or ice contamination, while anti-icing fluids are used before takeoff to prevent frost or ice contamination from occurring for a period of time(referred to as "holdover time") after application. Thickened deicing/anti-icing fluids can affect airplane performance and handling characteristics and their residue may cause stiff or frozen flight controls. This study also describes an approval process that may be used by type certificate holders and applicants for a type certificate under parts 23 to support operational use of these fluids on their airplanes.

Development of Machine Learning Model to Predict Hydrogen Maser Holdover Time (수소 메이저 홀드오버 시간예측을 위한 머신러닝 모델 개발)

  • Sang Jun Kim;Young Kyu Lee;Joon Hyo Rhee;Juhyun Lee;Gyeong Won Choi;Ju-Ik Oh;Donghui Yu
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.13 no.1
    • /
    • pp.111-115
    • /
    • 2024
  • This study builds a machine learning model optimized for clocks among various techniques in the field of artificial intelligence and applies it to clock stabilization or synchronization technology based on atomic clock noise characteristics. In addition, the possibility of providing stable source clock data is confirmed through the characteristics of machine learning predicted values during holdover of atomic clocks. The proposed machine learning model is evaluated by comparing its performance with the AutoRegressive Integrated Moving Average (ARIMA) model, an existing statistical clock prediction model. From the results of the analysis, the prediction model proposed in this study (MSE: 9.47476) has a lower MSE value than the ARIMA model (MSE: 221.2622), which means that it provides more accurate predictions. The prediction accuracy is based on understanding the complex nature of data that changes over time and how well the model reflects this. The application of a machine learning prediction model can be seen as a way to overcome the limitations of the statistical-based ARIMA model in time series prediction and achieve improved prediction performance.

Tae-Baek Natural History Museum Project (태백 고생대 박물관 계획)

  • Lee, Moo-Sang
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2007.05a
    • /
    • pp.75-76
    • /
    • 2007
  • Recently with increasing interest in the natural science history education, a lot of natural science museums have been developed in various locations. This project is located in one of the biggest Paleozoic site, Taebak Kangwon-do. This kind museum has had important rolls in terms of education for student, destination for traveling and reservation of important holdover of the old ages. To do those kind of parts, this project has been designed with concepts and themes like; i. being organized with story telling structure with theme "secret of life and earth from Taebak" ii. combining experiences between outdoor experimental search for the real fossils and indoor educational interactions with real size model and moving films. iii. designing with strong identities of Paleozoic era. For the design identities the outer appearance was designed with motive of trilbites in an abstract way and inside was finished with exposed concrete and various size of moving films projected to walls and floor to emphasize real scale experience of the old ages.

  • PDF

High-Performance Synchronization for Circuit Emulation in an Ethernet MAN

  • Hadzic Ilija;Szurkowski Edward S.
    • Journal of Communications and Networks
    • /
    • v.7 no.1
    • /
    • pp.1-12
    • /
    • 2005
  • Ethernet is being deployed in metropolitan area networks (MANs) as a lower-cost alternative to SONET-based infrastructures. MANs are usually required to support common communication services, such as voice and frame relay, based on legacy synchronous TDM technology in addition to asynchronous packet data transport. This paper addresses the clock synchronization problem that arises when transporting synchronous services over an asynchronous packet infrastructure, such as Ethernet. A novel algorithm for clock synchronization is presented combining time-stamp methods used in the network time protocol (NTP) with signal processing techniques applied to measured packet interarrival times. The algorithm achieves the frequency accuracy, stability, low drift, holdover performance, and rapid convergence required for viable emulation of TDM circuit services over Ethernet.