• 제목/요약/키워드: high strength reinforcing bars

검색결과 116건 처리시간 0.019초

고강도 콘크리트 휨 부재의 철근 겹이음에 대한 연구 (Lapped Splices in High-Strength Concrete Flexural Members)

  • 김우;김준성;김대중;손영현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.447-452
    • /
    • 1996
  • An experimental study was conducted to evaluate the bond performance of reinforcing bars embedded in high-strength concrete. Ten beam spice Specimens using concrete with compressive strength of 240kg/$\textrm{cm}^2$ and 640kg/$\textrm{cm}^2$ were tested. The effect of several variables on basic development length is discussed. The test results showed that the current trend in concrete specification of making the splice length longer to compensate for having smaller cover and spacing may not be an effective approach.

  • PDF

Bond-Strengthening Hooks for RC Members with High Strength Spirals

  • Kim Kil-Hee;Sato Yuichi
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.835-842
    • /
    • 2005
  • This paper presents an experimental investigation of bond-strengthening hooks as a new method to increase bond strength along flexural reinforcing bars in reinforced concrete (RC) beams and columns. The RC members, which consisted of 1,300 MPa-class spirals as shear reinforcement, often suffered from bond splitting failure. The proposed method attempts to increase confining stiffness around the flexural bars by placing U-shaped hooks and to prevent premature bond splitting failure. Twelve specimens with varied amounts and sizes of the hooks were prepared to verify the strengthening effectiveness under monotonic and cyclic loading conditions. The test result indicated that the hooks increased the bond strength along the flexural bars although the strengthening effectiveness was limited by effective reinforcement ratio $P_{be}$. This limit is determined by size of stress-transmitting zones of concrete around anchors of the hooks. Anchors of the hooks are recommended to be longer than twelve times the hook diameter and inserted deeper than a quarter of the member depth (D/4). Proposed design equations provide modest estimates of the shear strengths.

콘크리트 압축강도 측정법과 공시체 내 철근이 압축강도 측정에 미치는 실험적 연구 (An Experimental Study on the Compressive Strength of Reinforcing Bars in Concrete Specimens and Compressive Strength Measurement Methods)

  • 이원홍;최상기;이승열;안진희;강범주
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권6호
    • /
    • pp.33-40
    • /
    • 2021
  • 콘크리트 구조물의 안전성 검토에서 콘크리트 압축강도 측정은 매우 중요한 요소이다. 콘크리트 압축강도 측정법에는 파괴방법과 비파괴방법이 있다. 파괴방법은 일축압축파괴방법이 있으며, 비파괴방법에는 반발경도법과 탄성파 측정법이 있다. 본 연구에는 측정법의 종류와 콘크리트 내부의 철근영향에 따른 콘크리트의의 압축강도 영향을 분석하였다. 공시체의 종류와 상관없이 3가지 실험 방법 중 탄성파 측정법에 의한 평균 압축강도가 다른 방법에 의한 평균 압축강도보다 크게 나타났다. 공시체 종류가 같을 경우 탄성파 측정법이 다른 측정법들에 비해 측정값들의 표준편차가 작게 나타났으므로 탄성파 측정법이 다른 두 측정법에 비해 측정값의 변동이 크지 않음을 알 수 있다. 각 공시체별 실험 방법에 따른 평균압축강도를 압축파괴 실험법의 평균압축 강도를 기준으로 비교하면 탄성파 측정법, 압축파괴실험, 반발경도법 순으로 평균압축강도가 높게 측정되었다. 콘크리트의 압축강도 측정방법과 콘크리트 내부 철근 유무에 따라 콘크리트 압축강도 측정값이 상이하므로 추후 피복두께의 영향 등을 고려한 연구가 필요할 것이다.

수종의 섬유보강재가 복합레진의 파절강도에 미치는 영향 (FRACTURE STRENGTH OF COMPOSITE RESIN WITH VARIOUS FIBER REINFORCING MATERIALS)

  • 박지만;조용범;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제25권3호
    • /
    • pp.371-380
    • /
    • 2000
  • The effect of fiber reinforcing materials on the fracture strength of composite resin was evaluated. Each ten composite resin bars reinforced by glassfiber[Fiber-Splint ML$^{(R)}$(Polydentia SA, Switzerland)], polyethylene fiber [Ribbond$^{(R)}$(Ribbond Inc., U.S.A.)] and polyaramid fiber[Kevlar$^{(R)}$(DuPont, U.S.A.)] were loaded under the 3-point compression technique. Another ten pure composite resin bars without reinforcement were used as a control group. Then mean fracture strength and standard deviation were calculated and a ANOVA and Scheffe test were used in statistics. The results were as follows: 1. Kevlar group showed the highest fracture strength as 175.5MPa (p<0.05). Fiber-Splint ML group showed the lowest fracture strength as 112.7MPa. 2. The mean value of fracture strength in Ribbond group was 136.4MPa, and that of unterated control group was 143.6MPa. No difference was found between the two groups. 3. Ribbond and Kevlar reinforcement groups showed a catastrophic failure, where complete separation of pieces occurs to a unseparated fracture pattern. The use of Kevlar reinforcement fibers with composite resin showed significant increase in the average load failure and the presence of the fibers did prevent the catastrophic crack propagation present in the unreinforced samples. The use of Ribbond reinforcement fibers with composite resin showed no significant increase in the average load failure. However, the presence of the fibers did prevent the catastrophic crack propagation. Because high strength of glassfiber are rapidly degraded on exposure to moisture and humidity. The use of Fiber-Splint ML reinforcement fibers with composite resin showed significant decrease in the average load failure and displayed catastrophic fractures.

  • PDF

고강도철근 기계적정착의 원전구조물 적용을 위한 성능평가실험 (Performance Evaluation Test for Applying the Mechanical Development of the High-Strength Reinforcing Bars to the Nuclear Power Plant Structures)

  • 이병수;방창준;임상준;김석철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.197-198
    • /
    • 2012
  • If the mechanical development be applied to the Nuclear Power Plant Structures instead of the standard hook development, the problem of overcrowding re-bars in the anchorage zone can be solved and the construction quality of the concrete work will be improved. But there are some problems in applying it to the NPP structures because of the restriction on the re-bar yield strength and diameter. After the performance evaluation test for the mechanical development, we can develop the new design equation of the mechanical development length in order to solve the limitation and apply it to NPP structures.

  • PDF

고강도 강봉을 이용한 철근 콘크리트 보의 보강에 관한 연구 (Rehabilitation of RC Beams with High Tension Steel Bars)

  • 양재연;박순규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.438-441
    • /
    • 2004
  • This paper presents the results of the experimental study on the performances of reinforced concrete beams rehabilitated by external unbonded high tension steel-bar. Design variables for the experiment in this study includes the position of anchorage zone of the high tension steel bar, the anchorage length of the reinforcing steel bar and the types of the shear strengthening measures. 5 specimens were tested with one point monotonically increased loads and structural performances such as strength capacities, ductility capacities and failure modes were analysed. It is found that the structural performance of the rehabilitated beams are strongly depended on the location of anchorage zone of the high tension steel-bars. In the case that anchorage zone is located near the critical shear zone, it is observed that the rehabilitated beam is failed in brittle failure mode and the additional shear strengthening is necessitated. But if anchorage zone is properly located or additional shear strengthening device is provided properly, it is also observed that the strength capacity of the rehabilitated beams could be increased more than $200\%$ by the proposed method.

  • PDF

고온과 고온노출 후 GFRP 보강근의 잔존인장성능 비교 (A Comparison of Residual Tensile Properties of GFRP Reinforcing Bar at High Temperature and after Exposure to High Temperature)

  • 김성도;문도영
    • 대한토목학회논문집
    • /
    • 제35권1호
    • /
    • pp.77-84
    • /
    • 2015
  • 고온에 노출된 GFRP 보강근의 인장실험을 수행하였다. 본 실험을 위한 고온노출조건은 $200^{\circ}C$ 이하의 온도에 3분간 노출하는 것으로 하였다. 이러한 조건은 다른 연구자들의 시험에서 적용한 고온노출조건과 비교하여 경미한 고온노출조건이다. 고온에서와 고온노출 후 GFRP 보강근의 인장강도와 탄성계수를 비교하였다. 실험결과, 고온에서 GFRP 보강근의 인장성능이 감소하는 것으로 나타났으나, 고온노출 후 보강근의 인장성능은 거의 고온노출전의 수준으로 회복되는 것으로 나타났다. 이와 같은 결과는 화재로 손상 받은 GFRP 보강 콘크리트 구조물의 평가를 위하여 중요한 자료가 된다.

중공단면 고강도 철근 콘크리트 교각의 연성거동에 관한 실험적 연구 (Ductility performance of hollow-section reinforced concrete piers using high-strength reinforcing bars)

  • 오병환;박대균;조근호;신용석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.730-733
    • /
    • 2004
  • Three Hollow RC piers were tested under a constant axial load and a cyclically reversed horizontal loadto investigate the structural behavior of hollow RC piers using the high strength concrete and the high strength rebars. The test variables include concrete compressive strength, steel strength, and steel ratio. The test results indicate that RC piers using the high strength concrete and high strength rebars exhibit ductile behavior and appropriate seismic performance, in compliance with the design code. The present study allows more realistic application of high strength rebars and concrete to RC piers, which will provide enhanced durability as well as more economy.

  • PDF

초고강도 섬유보강 콘크리트 분절형 박스 거더의 휨거동 (Flexural Behavior of Ultra High Performance Fiber Reinforced Concrete Segmental Box Girder)

  • 궈칭용;한상묵
    • 콘크리트학회논문집
    • /
    • 제26권2호
    • /
    • pp.109-116
    • /
    • 2014
  • 압축강도 160MPa과 길이 15.4 m를 가진 초고강도 섬유보강 콘크리트 분절박스 거더의 휨거동 실험을 수행하였다. 초고강도 섬유보강 콘크리트 분절 박스에 연성거동 특성을 보강하기 위한 강섬유와 종방향철근의 조합 효과를 두종류의 강섬유 혼입률로 제작된 초고강도 분절형 박스거더의 휨거동을 비교함으로써 평가하였다. 강섬유 혼입률이 1%이고 전단철근과 상부플랜지와 복부에 종방향철근으로 보강한 초고강도 콘크리트 박스거더 BF2의 거동은 탄성응력대에서 전단철근 없이 강섬유 혼입률 2%인 초고강도 섬유보강 콘크리트 박스거더와 유사한 연성거동을 보여준다. 그러나 비선형응력대에서는 BF1의 강성이 약간 더 크고 안정적인 연성거동 형태를 보여주고 있다. 초고강도 섬유보강 콘크리트 박스거더의 분절면은 휨파괴 시까지 균열이나 슬립이 발생하지 않았다.

Head 플레이트 상세에 따른 Headed Bars의 인발거동에 관한 연구 (Pull-out Behaviors of Headed Bars with Different Details of Head Plates)

  • 박현규;윤영수;류영섭;이만섭
    • 한국방재학회 논문집
    • /
    • 제2권2호
    • /
    • pp.95-104
    • /
    • 2002
  • 이 논문은 콘크리트 콘 파괴에 의해 지배될 때의 인장력의 예측과 Headed bar의 인발 파괴 양상을 보여준다. 1개의 다른 플레이트 형상과 세가지의 서로 다른 용접 방법에 따라 시험이 이루어졌다. 시험의 변수는 Headed plate에 연결된 철근의 직경(16mm, 19mm, 22mm), 형상(원형, 직사각형, 정사각형)과 head plate의 차원(면적, 두께), 철근과 head plate와의 연결을 위한 용접 방법(일반용접, 마찰용접)이다. Headed bar는 ASTM 970-98에 기초한 모양과 두께를 가진 다른 단면적으로 제조되었으며 콘크리트의 부착 길이는 CSA 23.3-94에 의거하여 산정되었다. 정적 인장하중이 적용되었으며 시험 인발 성능은 ACI-349와 CCD 방법과 같은 현재의 설계방법에 의해 산출된 값과 비교하였다. 실험결과와 기존식을 비교하면 Headed bar가 앵커와 달리 넓은 플레이트 면적과 이형철근으로 인해 기준식에 비해 높은 강도와 큰 파괴 반경을 나타내었다.