Rehabilitation of RC Beams with High Tension Steel Bars

고강도 강봉을 이용한 철근 콘크리트 보의 보강에 관한 연구

  • Published : 2004.05.01

Abstract

This paper presents the results of the experimental study on the performances of reinforced concrete beams rehabilitated by external unbonded high tension steel-bar. Design variables for the experiment in this study includes the position of anchorage zone of the high tension steel bar, the anchorage length of the reinforcing steel bar and the types of the shear strengthening measures. 5 specimens were tested with one point monotonically increased loads and structural performances such as strength capacities, ductility capacities and failure modes were analysed. It is found that the structural performance of the rehabilitated beams are strongly depended on the location of anchorage zone of the high tension steel-bars. In the case that anchorage zone is located near the critical shear zone, it is observed that the rehabilitated beam is failed in brittle failure mode and the additional shear strengthening is necessitated. But if anchorage zone is properly located or additional shear strengthening device is provided properly, it is also observed that the strength capacity of the rehabilitated beams could be increased more than $200\%$ by the proposed method.

Keywords