• 제목/요약/키워드: high pressure discharge

검색결과 511건 처리시간 0.026초

전화를 이용한 퇴원환자 만족도 조사 (The Measurement Of Postdischarge Patient Satisfaction Using Telephone Interview)

  • 송정흡
    • 한국의료질향상학회지
    • /
    • 제4권1호
    • /
    • pp.104-114
    • /
    • 1997
  • Background : Hospitals(Health care providers) are under tremendous pressure to meet consumer demands in order to compete in the rapidly changing health care arena. Through evaluating patient satisfaction, hospitals(health care providers) can learn what the consumer Wants from the health care system. Timely feedback is necessary. The purpose of this study is to evaluate patients' hospital experience and satisfaction using telephone interview and to study the usefulness for telephone interview at assessing patient satisfaction. Method : The 846 patients who were discharged from September 17, 1996 to October 11, 1996 were targeted were telephoned. The informations gathered telephone survey were processed by computer and analyzed for the patient satisfaction, contributing factors. Result : The 846 patients who were discharged from September 17, 1996 to October 11, 1996 were called and 197 patients(23.3%) were successful interviewed. 51.3 percent of respondents were male and mean age is 39 years mean LOS(length of stay) is 13 days and 110(56.1%) patients were admitted by outpatients clinic. The mean calling-time is 5.5 minutes. There is no significant difference between interviewers(telemarketer) in patients satisfaction. Seven telephone interviews are possible by interview a day. There in no significant difference between groups in patients satisfaction in length of stay, path of admission, the interval between discharge and interview. 97.5 percent of respondents were satisfied with telephone interview and 81.7% were satisfied with overall satisfaction and 79.4 % of respondents were good response in interviewers' conclusion. Of six variables that were found to be correlated with telephone interview and eight variables correlated with overall hospital satisfaction, a multiple logistic regression analysis revealed that two most important variables which are significantly correlated with telephone interview are to meet doctors, not ask tediously then three variables which are with overall satisfaction are doctors explain, subject response, convenient facilities. Conclusion : The patients interviewed are satisfied with telephone interview. Telephone interview is good method for assessing patient satisfaction, making high levels of patient satisfaction and for hospital marketing.

  • PDF

Controlling the surface energy and electrical properties of carbon films deposited using unbalanced facing target magnetron sputtering plasmas

  • Javid, Amjed;Kumar, Manish;Yoon, Seok Young;Lee, Jung Heon;Han, Jeon Geon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.231.1-231.1
    • /
    • 2015
  • Surface energy, being an important material parameter to control its interactions with the other surfaces plays a key role in bio-related application. Carbon films are found very promising due to their characteristics such as wear and corrosion resistant, high hardness, inert, low resistivity and biocompatibility. The present work deals with the deposition of carbon films using unbalanced facing target magnetron sputtering technique. The discharge characteristics were studied using optical emission spectroscopy and correlated with the film properties. Surface energy was investigated through contact angle measurement. The ID/IG ratio as calculated from Raman spectroscopy data increases with the increase in power density due to the higher number of sp2 clusters embedded in the amorphous matrix. The deposited films were smooth and homogeneous as observed by Atomic force microscopy having RMS roughness in the range of 1.74 to 2.25 nm. It is observed that electrical resistivity and surface energy varies in direct proportionality with operating pressure and has inverse relation with power density. The surface energy results clearly exhibited that these films can have promising applications in cell cultivation.

  • PDF

CC 산화제 개폐밸브 성능향상에 관한 연구 (Study on the performance improvement of a Main Oxidizer shut-off Valve)

  • 배영우;김도형;홍문근;이수용;장기원
    • 항공우주기술
    • /
    • 제9권2호
    • /
    • pp.63-72
    • /
    • 2010
  • 발사체 추진시스템에서 CC(Combustion Chamber) 산화제 개폐밸브는 액체산소를 연소기로 공급 및 차단함으로써 연소를 개시 및 중단시킬 뿐만 아니라, 정상운영 상태에서는 연소기 내 안정된 연소가 가능하도록 일정한 유량의 액체산소를 공급한다. TM(Technology Model)에 비해 높은 유출계수를 가지는 EM(Engineering Model)이 전반적인 요구 성능을 만족하는 것으로 나타났지만, 성능 향상을 위해 EM의 주요 부분에 대한 추가적인 설계 변경을 수행하였다. 공압 제어부, 중간 플랜지, 그리고 밸브 입구의 립 부분의 형태를 설계 변경하였으며, 해당 시험 시제를 제작하여 성능시험을 수행하였다. 이러한 성능 시험을 통해 의도했던 성능 향상이 이루어진 것을 최종 확인하였다.

플라즈마 충진 촉매 시스템을 이용한 에틸렌 저감 연구 (Decomposition of Ethylene using a Hybrid Catalyst-packed Bed Plasma Reactor System)

  • 이상백;조진오;장동룡;목영선
    • 한국대기환경학회지
    • /
    • 제30권6호
    • /
    • pp.577-585
    • /
    • 2014
  • A series of experiments using atmospheric-pressure non-thermal plasma coupled with transition metal catalysts were performed to remove ethylene from agricultural storage facilities. The non-thermal plasma was created by dielectric barrier discharge, which was in direct contact with the catalyst pellets. The transition metals such as Ag and $V_2O_5$ were supported on ${\gamma}-Al_2O_3$. The effect of catalyst type, specific input energy (SIE) and oxygen content on the removal of ethylene was examined to understand the behavior of the hybrid plasma-catalytic reactor system. With the other parameters kept constant, the plasma-catalytic activity for the removal of ethylene was in order of $V_2O_5/{\gamma}-Al_2O_3$ > $Ag/{\gamma}-Al_2O_3$ > ${\gamma}-Al_2O_3$ from high to low. Interestingly, the rate of plasma-catalytic ozone generation was in order of $V_2O_5/{\gamma}-Al_2O_3$ > ${\gamma}-Al_2O_3$ > $Ag/{\gamma}-Al_2O_3$, implying that the catalyst activation mechanisms by plasma are different for different catalysts. The results obtained by varying the oxygen content indicated that nitrogen-derived reactive species dominated the removal of ethylene under oxygen-lean condition, while ozone and oxygen atoms were mainly involved in the removal under oxygen-rich condition. When the plasma was coupled with $V_2O_5/{\gamma}-Al_2O_3$, nearly complete removal of ethylene was achieved at oxygen contents higher than 5% by volume (inlet ethylene: 250 ppm; gas flow rate: $1.0Lmin^{-1}$; SIE: ${\sim}355JL^{-1}$).

고효율 PDP 제작을 위한 진공 인라인 실장에서의 초기 진공도에 따른 방전특성 분석 (The Analysis of the Discharging Characteristics on the Base Vacuum Level in a Vacuum In-line Sealing Process for High-efficiency PDP)

  • 권상직;장찬규;김용재
    • 한국진공학회지
    • /
    • 제15권1호
    • /
    • pp.57-63
    • /
    • 2006
  • 진공 인라인 실장기술에 의해 제조된 프라즈마 디스플레이 패널(PDP)의 전기적 및 광학적 특성을 분석하였다. 분석결과, 초기 진공도가 증가함에 따라 발광효율이 증가함을 확인하였다 즉, $1\times10^{-3}$ torr의 진공도인 경우에 대해서는, 동작전압이 235 V(방전가스의 압력을 400 Torr일 경우) 이고 발광효율이 0.8 1n,/W(180 V의 유지전압에 대해) 인데 반해 초기 진공도가 $1\times10^4 torr$일 경우에 대해서는, 동작전압이 215V로 낮아졌고 발광효율은 2.5lm/W로 향상되었음을 확인하였다. 더불어, 진공 인-라인 실장 방법을 이용하여 tip-]ess형 PDP 동작 패널을 성공적으로 제조할 수 있었다.

연료전지 자동차용 이산화탄소 열펌프 시스템의 성능평가 (Performance Evaluation of a $CO_2$ Heat Pump System for Fuel Cell Vehicles)

  • 김성철;박종철;김민수;원종필
    • 한국자동차공학회논문집
    • /
    • 제16권1호
    • /
    • pp.37-44
    • /
    • 2008
  • The global warming potential (GWP) of $CO_2$ refrigerant is 1/1300 times lower than that of R134a. Furthermore, the size and weight of the automotive heat pump system can decrease because $CO_2$ operates at high pressure with significantly higher discharge temperature and larger temperature change. The presented $CO_2$ heat pump system was designed for both cooling and heating in fuel cell vehicles. In this study, the performance characteristics of the heat pump system were analyzed for heating, and results for performance were provided for operating conditions when using recovered heat from the stack coolant. The performance of the heat pump system with heater core was compared with that of the conventional heating system with heater core and that of the heat pump system without heater core, and thus the heat pump system with heater core showed the best performance among the selected heating systems. On the other hand, the heating performance of two different types of coolant/air heat pump systems with heater core was compared each other at various coolant inlet temperatures. Furthermore, to use exhausted thermal energy through the radiator, experiments were carried out by changing the arrangement of a radiator and an outdoor evaporator, and quantified the heating effectiveness.

DBD 플라즈마 구동기를 이용한 원통모델의 공기저항저감 (Aerodynamic Drag Reduction in Cylindrical Model Using DBD Plasma Actuator)

  • 이창욱;심주형;한성현;윤수환;김태규
    • 한국추진공학회지
    • /
    • 제19권1호
    • /
    • pp.25-32
    • /
    • 2015
  • 원통 모델에 공기저항저감 효과를 검증하기 위해서 원통형에 적합한 유연성 플라즈마 구동기를 제작하였다. 다양한 풍속에서 플라즈마 유동제어 풍동시험을 수행하였으며, CFD 해석과 유동가시화를 수행하였다. 풍속이 느린 저속 구간에서는 유동박리가 발생하지 않아 플라즈마 유동제어 효과가 없었다. 풍속 14 m/s 에서 14% 정도 항력이 저감되었으며, 풍속이 증가된 17 m/s 의 경우 항력이 27% 저감되었다. CFD 해석과 유동가시화의 비교를 통해 DBD플라즈마 구동기는 원통 주변의 압력차를 감소시켜 와류의 크기가 줄어든 것으로 확인되었다.

강우침투실험을 통한 불포화 풍화토 지반의 강우 침투속도 분석 (Analysis of Seepage Velocity in Unsaturated Weathered Soils Using Rainfall Infiltration Test)

  • 김훈;신호성;김윤태;박덕근;민덕기
    • 한국지반공학회논문집
    • /
    • 제28권2호
    • /
    • pp.71-78
    • /
    • 2012
  • 본 연구에서는 실내 강우침투실험을 통하여 강우강도에 따른 지반 내 침투속도를 산정하였으며, 침투특성을 분석하여 보았다. 또한 수치해석을 이용한 해석결과와 비교 검증을 수행하였으며, 시간에 따른 간극수압과 포화도 그리고 유출속도의 변화는 대체로 잘 일치함을 보였다. 강우강도에 따른 침투속도는 실내실험과 수치해석에서 선형적으로 증가하는 경향을 나타냈으며, 강우강도가 지반의 포화투수계수에 근접시 침투속도가 급격히 증가하였다. 또한 강우 침투시 습윤전선의 상부는 부분적으로 포화되어 침투하는 경향을 보였다. 따라서 실제 지반에서 습윤전선은 비교적 빠르게 진행하여 사면의 불안정을 초래할 것으로 판단된다.

Triode magnetron sputtering system의 제작 및 특성평가 (Characteristic evaluations and production of triode magnetron sputtering system)

  • 김현후;이무영;김광태;윤상현;유환구;김종민;박철현;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.787-790
    • /
    • 2003
  • A rf triode magnetron sputtering system is designed and installed its construction in vacuum chamber. In order to calibrate the rf triode magnetron sputtering for thin films deposition processes, the effects of different glow discharge conditions were investigated in terms of the deposition rate measurements. The basic parameters for calibrating experiment in this sputtering system are rf power input, gas pressure, plasma current, and target-to-substrate distance. Because a knowledge of the deposition rate is necessary to control film thickness and to evaluate optimal conditions which are an important consideration in preparing better thin films, the deposition rates of copper as a testing material under the various sputtering conditions are investigated. Furthermore, a triode sputtering system designed in our team is simulated by the SIMION program. As a result, it is sure that the simulation of electron trajectories in the sputtering system is confined directly above the target surface by the force of $E{\times}B$ field. Finally, some teats with the above 4 different sputtering conditions demonstrate that the deposition rate of rf triode magnetron sputtering is relatively higher than that of the conventional sputtering system. This means that the higher deposition rate is probably caused by a high ion density in the triode and magnetron system. The erosion area of target surface bombarded by Ar ion is sputtered widely on the whole target except on both magnet sides. Therefore, the designed rf triode magnetron sputtering is a powerful deposition system.

  • PDF

양극산화와 열수처리한 Ti-6Al-7Nb 합금의 표면 특성 (Surface Characteristics of Anodized and Hydrothermally-Treated Ti-6Al-7Nb Alloy)

  • 김문영;송광엽;배태성
    • 구강회복응용과학지
    • /
    • 제21권1호
    • /
    • pp.33-42
    • /
    • 2005
  • This study was performed to investigate the surface properties and in vitro biocompatibility of electrochemically oxidized Ti-6Al-7Nb alloy by anodic spark discharge technique. Discs of Ti-6Al-7Nb alloy of 20 mm in diameter and 2 mm in thickness were polished sequentially from #300 to 1000 SiC paper, ultrasonically washed with acetone and distilled water for 5 min, and dried in an oven at $50^{\circ}C$ for 24 hours. Anodizing was performed using a regulated DC power supply. The applied voltages were given at 240, 280, 320, and 360 V and current density of $30mA/cm^2$. Hydrothermal treatment was conducted by high pressure steam at $300^{\circ}C$ for 2 hours using a autoclave. Samples were soaked in the Hanks' solution with pH 7.4 at $36.5^{\circ}C$ during 30 days. The results obtained were summarized as follows; 1. The oxide films were porous with pore size of $1{\sim}5{\mu}m$. The size of micropores increased with increasing the spark forming voltage. 2. The main crystal structure of the anodic oxide film was anatase type as analyzed with thin-film X-ray diffractometery. 3. Needle-like hydroxyapatite (HA) crystals were observed on anodic oxide films after hydrothermal treatment at $300^{\circ}C$ for 2 hours. The precipitation of HA crystals was accelerated with increasing the spark forming voltage. 4. The precipitation of the fine asperity-like HA crystals were observed after being immersed in Hanks' solution at $37^{\circ}C$. The precipitation of HA crystals was accelerated with increasing the spark forming voltage and the time of immersion in Hanks' solution. 5. The Ca/P ratio of the precipitated HA layer was equivalent to that of HA crystal as increasing the spark forming voltage and the time of immersion in Hanks' solution.